7.0 RETURN OF SETRA SYSTEMS PRODUCT-DECLARATION
(Form 206ERN)
EXPECTED RETURN NUMBER _______________________________________________ You must:
• Contact your supplier if you have any questions and for an ERN Number.
• Send this form to your supplier with the return of the product.
SECTION 1: Product
A. Model Number _____________________ B. Serial Number ______________________ C. Has the product been used, tested or operated?
Yes - Go to Section 2 No - Go to Section 4
SECTION 2: Substances in Contact with the Product A. Radioactive* Yes No B. Biologically Active Yes No C. Dangerous to Human Health and Safety? Yes No * Note: Your supplier will not accept delivery of any products that are contaminated with radioactive substances, unless you:
• Decontaminate the products
• Provide proof of decontamination
YOU MUST CONTACT YOUR SUPPLIER FOR ADVICE BEFORE YOU RETURN SUCH PRODUCTS
If you have answered “no” to all of these questions, go to Section 4.
Substance Name Chemical
Symbol
1.
2.
3.
4.
5.
6.
SECTION 3: List of Substances in Contact with the Product SECTION 4: Return Information Reason for return and symptoms of malfunction: ______________________________
_______________________________________________________________________
If you have a warranty claim:
• Who did you buy the product from?: _______________________________________
• Give the supplier’s invoice number or your purchase order number: ______________
SECTION 5: Declaration
Print your Name: _______________________ Print Your Job Title: ________________ Print Your Company Name: ________________________________________________
Print Your Address: _______________________________________________________
Telephone Number: ____________________ Date of Product Return:_____________ I have made reasonable inquiry and I have supplied accurate information in this Declaration. I have not withheld any information. I have followed the Return of Setra Systems Product Procedure.
Signed: ______________________________ Date: ___________________
Precautions Required (eg: use
protective gloves, etc.)
Actions Required After
Spillage or Human Contact
MODEL 206
Industrial Pressure Transducer
OPERATING INSTRUCTIONS
Boxborough, MA USA
Toll Free: 800-257-3872 | 978-263-1400
SS0478 Rev G
sales@setra.com | www.setra.com
159 Swanson Road
Fax: 978-264-0292
1.0 General Information
Every Model 206 has been tested and calibrated before shipment. Performance specications are shown on page X of this guide.
Setra Systems Model 206 pressure transducers sense gauge and vacuum
pressure and convert this pressure dierence to a proportional high level analog output. Two standard output and excitation versions are oered:
Excitation Output
9 to 30 VDC 4 to 20 mA (must observe polarity)
12 to 28 VDC 0.1 to 5.1 VDC (reverse wire protection up to 22VDC
excitation to the output lead
2.0 Mechanical Installation
2.1 Media Compatibility
Model 206 transducers are designed to be used with any gases or liquids
compatible with 17-4 PH stainless steel.
2.2 Environment
The operation temperature limits of the 206 are -40° to +260°F (-40 to
+127°C).
The compensated temperature range is -4 to +176°F (-20 to +80°C).
2.3 Pressure Fittings
Typically, standard pipe ttings and procedures should be used. However,
for pressure ranges in excess of 500 PSIG (35 Bar) we suggest the use of a sealant such as Loctite Hydraulic Sealant. Excessive torquing of metal t­tings may cause a slight zero shift. The use of plastic ttings typically results in no noticeable zero shift. Torquing does not appreciably aect linearity or sensitivity.
2.4 Venting
The reference pressure in a sealed gage transducer will vary due to changes
in temperature, atmospheric pressure, humidity, etc. This change aects the overall accuracy of the unit. To compensate all gage and compound 206 units are vented to atmosphere using the following methods based on the electrical termination used.
6.0 Warranty & Limitation of Liability
SETRA warrants its products to be free from defects in materials and work­manship, subject to the following terms and conditions: Without charge, SETRA will repair or replace products found to be defective in materials or workmanship within the warranty period; provided that:
a) the product has not been subjected to abuse, neglect, accident, incor-
rect wiring not our own, improper installation or servicing, or use in violation of instructions furnished by SETRA;
b) the product has not been repaired or altered by anyone except SETRA or
its authorized service agencies;
c) the serial number or date code has not been removed, defaced, or oth-
erwise changed; and
d) examination discloses, in the judgment of SETRA, the defect in materials
or workmanship developed under normal installation, use and service;
e) SETRA is notied in advance of and the product is returned to SETRA
transportation prepaid.
Unless otherwise specied in a manual or warranty card, or agreed to in writ­ing and signed by a SETRA ocer, SETRA pressure and acceleration products shall be warranted for one year from date of sale.
The foregoing warranty is in lieu of all warranties, express, implied or statu­tory, including but not limited to, any implied warranty of merchantability for a particular purpose.
SETRA’s liability for breach of warranty is limited to repair or replacement, or if the goods cannot be repaired or replaced, to a refund of the purchase price. SETRA’s liability for all other breaches is limited to a refund of the purchase price. In no instance shall SETRA be liable for incidental or consequential damages arising from a breach of warranty, or from the use or installation of its products.
No representative or person is authorized to give any warranty other than as set out above or to assume for SETRA any other liability in connection with the sale of its products.
1
6
5.0 RETURNING PRODUCTS FOR REPAIR
Please contact a Setra application engineer (800-257-3872, 978-263-1400) before returning unit for repair to review information relative to your ap­plication. Many times only minor eld adjustments may be necessary. When returning a product to Setra, the material should be carefully packaged and shipped prepaid to:
Setra Systems, Inc. 159 Swanson Road Boxborough, MA 01719-1304 Attn: Repair Department
To ensure prompt handling, please supply the following information and include it inside the package or returned material:
• Name and phone number of person to contact.
• Shipping and billing instructions.
• Full description of the malfunctions.
• Identify any hazardous material used with the product.
Notes: Please remove any pressure ttings and plumbing that you have installed and
enclose any required mating electrical connectors and wiring diagrams.
Allow approximately 3 weeks after receipt at Setra for the repair and return of
the unit. Non-warranty repairs will not be made without customer approval and a purchase order to cover repair chargers.
Cable Termination and Hirschmann Models
All 206 models with a cable termination or Hirschmann connector vent
through the cable to maintain proper accuracy. Connection to the unit should be made in a junction box that is vented to atmosphere, with care taken to ensure that the end of the cable is not blocked or sealed.
The following junction box conguration is a recommended method
for connecting to 206 units in order to achieve a moisture resistant and vented connection.
Termination Junction Box Strain relief
Part Number: Q1388PCE 3237 Heyco Flex tting
Dimensions: 4.92” x 2.95” x2.95” 2.50” Long
Manufacturer: Homan Engineering Co.
900 Ehlen Drive Anoka, MN 55303
(612) 421-2240
Heyco Kenilworth, NJ 07033
(201) 245-0033 (800) 526-4182
Calibration Services
Setra maintains a complete calibrations facility that is traceable to the National Institute of Standards and Technology (NIST). If you would like to recalibrate or recertify your Setra pressure transducers or transmitters, please call our Repair Department at 800-257-3872 (978-263-1400) for scheduling.
• Drill one ½” dia. Hole at each of the junction box for cable strain reliefs.
• Drill and tap one ½” – 13 NC hole in bottom of junction box and install loosely one ½” – 13 NC plastic or stainless steel screw. The clearance between threads serves as ventilation.
• Install cable strain reliefs in ½” holes.
• Mount junction box and install cables.
• A desiccant pack can be placed in the junction box for additional hu­midity protection.
Notes: The above directions are for cable termination models. Hirschmann and conduit connections require slight modications at the discretion of the installer.
Terminal Block Connections
All 206 models with terminal block connections are vented through a
porous plug on the connected; no additional venting is required during
installation.
25
3.0 Electrical Installation
The model 206 is available in the following electrical terminations:
• 2 foot cable (additional length available)
• 3-screw terminal block
• Hirschmann connector
• 1/2” conduit
3.1 Voltage Output Units
Wiring for cable, Hirschmann and conduit model 206 transducers with voltage output is as follows:
3.2 Current Output Units
Current output model 206 are true 2-wire, 4-20 mA current output devices and deliver rated current into an external load of 0-800 Ω. Cable termina­tion models have a 2-wire cable where red is positive and black is negative. On the Hirschmann connecter, pin 1 is positive; pin 2 is negative and pin 4 is the ground/shield. Terminal block units have outputs label + for positive and – for negative, the center terminal may be used for shielding.
Note: All 4-20 mA current output units are designed to have current ow in one direction only- PLEASE OBSERVE POLARITY. We suggest that the electrical cable shield be connected to the system’s loop circuit ground to improve
electrical noise rejection.
4.0 CALIBRATION
Every model 206 is factory calibrated and should require no eld adjust­ment. Whenever possible, any zero and/or span osets should be corrected by software adjustments in the user’s control system. However, both zero and span adjustments are accessible by removing the pan head screws and turning the zero and span potentiometer screws inside. Pan Head screws should be replaced after adjustment to maintain enclosure rating.
Cable & Conduit Hirschmann Pin Designation Connection to electrical system
Red #1 +Excitation; connect to 12-28 VDC power supply.
Green #3 +Output; connect to controller or monitor.
White #2 - Output; connect to controller or monitor.
Black #2 -Excitation; connect to return of 12-28 VDC power supply.
Shielding #4 Connect to system or earth ground.
Note 1: Model 206 can be wired as a three wire device by connecting -output and –excitation and shield to a common ground. However, accuracy will be reduced because of voltage drops in the leads.
Note 2: Mating Hirschmann connects #GDM3009J, Hirschmann #932214-100 with GDM3-16 Hirschmann Gasket #731531-002 are not provided by Setra Systems, unless ordered separately as an option.
Voltage output Model 206 with a 3 screw terminal block have excitation, out-
put and common termination pouts clearly marked, wiring is as follows.
Voltage output units are factory calibrated into a 50 KΩ load. Voltage units are operable into a 5000 Ω load or greater. The zero factory setting is ±50
mV.
Current outputs units (4-20 mA) are factory calibrated with a 24 VDC loop to supply voltage and a 250 Ω load. The zero factory setting is ±0.08 mA. The span (full scale) factory settings is ±0.16 mA. Zero and span adjustment are approximately ±1.0 mA.
3