EXPECTED RETURN NUMBER _______________________________________________
You must:
• Know about all of the substances which have been used and produced in the
product before you complete this Declaration.
• Contact your supplier if you have any questions and for an ERN Number.
• Send this form to your supplier with the return of the product.
SECTION 1: Product
A. Model Number _____________________
B. Serial Number ______________________
C. Has the product been used, tested or operated?
Yes - Go to Section 2 No - Go to Section 4
SECTION 2: Substances in Contact with the Product
A. Radioactive* Yes No
B. Biologically Active Yes No
C. Dangerous to Human Health and Safety? Yes No
* Note: Your supplier will not accept delivery of any products that are contaminated
with radioactive substances, unless you:
• Decontaminate the products
• Provide proof of decontamination
YOU MUST CONTACT YOUR SUPPLIER FOR ADVICE BEFORE YOU RETURN SUCH PRODUCTS
If you have answered “no” to all of these questions, go to Section 4.
Substance NameChemical
Symbol
1.
2.
3.
4.
5.
6.
SECTION 3: List of Substances in Contact with the Product
SECTION 4: Return Information
Reason for return and symptoms of malfunction: ______________________________
• Who did you buy the product from?: _______________________________________
• Give the supplier’s invoice number or your purchase order number: ______________
SECTION 5: Declaration
Print your Name: _______________________ Print Your Job Title: ________________
Print Your Company Name: ________________________________________________
Print Your Address: _______________________________________________________
Telephone Number: ____________________ Date of Product Return:_____________
I have made reasonable inquiry and I have supplied accurate information in this
Declaration. I have not withheld any information. I have followed the Return of Setra
Systems Product Procedure.
Every Model 206 has been tested and calibrated before shipment.
Performance specications are shown on page X of this guide.
Setra Systems Model 206 pressure transducers sense gauge and vacuum
pressure and convert this pressure dierence to a proportional high level
analog output. Two standard output and excitation versions are oered:
ExcitationOutput
9 to 30 VDC4 to 20 mA (must observe polarity)
12 to 28 VDC0.1 to 5.1 VDC (reverse wire protection up to 22VDC
excitation to the output lead
2.0 Mechanical Installation
2.1 Media Compatibility
Model 206 transducers are designed to be used with any gases or liquids
compatible with 17-4 PH stainless steel.
2.2 Environment
The operation temperature limits of the 206 are -40° to +260°F (-40 to
+127°C).
The compensated temperature range is -4 to +176°F (-20 to +80°C).
2.3 Pressure Fittings
Typically, standard pipe ttings and procedures should be used. However,
for pressure ranges in excess of 500 PSIG (35 Bar) we suggest the use of a
sealant such as Loctite Hydraulic Sealant. Excessive torquing of metal ttings may cause a slight zero shift. The use of plastic ttings typically results
in no noticeable zero shift. Torquing does not appreciably aect linearity or
sensitivity.
2.4 Venting
The reference pressure in a sealed gage transducer will vary due to changes
in temperature, atmospheric pressure, humidity, etc. This change aects
the overall accuracy of the unit. To compensate all gage and compound
206 units are vented to atmosphere using the following methods based on
the electrical termination used.
6.0 Warranty & Limitation of Liability
SETRA warrants its products to be free from defects in materials and workmanship, subject to the following terms and conditions: Without charge,
SETRA will repair or replace products found to be defective in materials or
workmanship within the warranty period; provided that:
a) the product has not been subjected to abuse, neglect, accident, incor-
rect wiring not our own, improper installation or servicing, or use in
violation of instructions furnished by SETRA;
b) the product has not been repaired or altered by anyone except SETRA or
its authorized service agencies;
c) the serial number or date code has not been removed, defaced, or oth-
erwise changed; and
d) examination discloses, in the judgment of SETRA, the defect in materials
or workmanship developed under normal installation, use and service;
e) SETRA is notied in advance of and the product is returned to SETRA
transportation prepaid.
Unless otherwise specied in a manual or warranty card, or agreed to in writing and signed by a SETRA ocer, SETRA pressure and acceleration products
shall be warranted for one year from date of sale.
The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not limited to, any implied warranty of merchantability for
a particular purpose.
SETRA’s liability for breach of warranty is limited to repair or replacement, or
if the goods cannot be repaired or replaced, to a refund of the purchase price.
SETRA’s liability for all other breaches is limited to a refund of the purchase
price. In no instance shall SETRA be liable for incidental or consequential
damages arising from a breach of warranty, or from the use or installation of
its products.
No representative or person is authorized to give any warranty other than as
set out above or to assume for SETRA any other liability in connection with the
sale of its products.
1
6
5.0 RETURNING PRODUCTS FOR REPAIR
Please contact a Setra application engineer (800-257-3872, 978-263-1400)
before returning unit for repair to review information relative to your application. Many times only minor eld adjustments may be necessary. When
returning a product to Setra, the material should be carefully packaged and
shipped prepaid to:
Setra Systems, Inc.
159 Swanson Road
Boxborough, MA 01719-1304
Attn: Repair Department
To ensure prompt handling, please supply the following information and
include it inside the package or returned material:
• Name and phone number of person to contact.
• Shipping and billing instructions.
• Full description of the malfunctions.
• Identify any hazardous material used with the product.
Notes: Please remove any pressure ttings and plumbing that you have installed and
enclose any required mating electrical connectors and wiring diagrams.
Allow approximately 3 weeks after receipt at Setra for the repair and return of
the unit. Non-warranty repairs will not be made without customer approval
and a purchase order to cover repair chargers.
Cable Termination and Hirschmann Models
All 206 models with a cable termination or Hirschmann connector vent
through the cable to maintain proper accuracy. Connection to the unit
should be made in a junction box that is vented to atmosphere, with care
taken to ensure that the end of the cable is not blocked or sealed.
The following junction box conguration is a recommended method
for connecting to 206 units in order to achieve a moisture resistant and
vented connection.
TerminationJunction BoxStrain relief
Part Number:Q1388PCE3237 Heyco Flex tting
Dimensions:4.92” x 2.95” x2.95”2.50” Long
Manufacturer:Homan Engineering Co.
900 Ehlen Drive
Anoka, MN 55303
(612) 421-2240
Heyco
Kenilworth, NJ 07033
(201) 245-0033
(800) 526-4182
Calibration Services
Setra maintains a complete calibrations facility that is traceable to the
National Institute of Standards and Technology (NIST). If you would like
to recalibrate or recertify your Setra pressure transducers or transmitters,
please call our Repair Department at 800-257-3872 (978-263-1400) for
scheduling.
• Drill one ½” dia. Hole at each of the junction box for cable strain reliefs.
• Drill and tap one ½” – 13 NC hole in bottom of junction box and install
loosely one ½” – 13 NC plastic or stainless steel screw. The clearance
between threads serves as ventilation.
• Install cable strain reliefs in ½” holes.
• Mount junction box and install cables.
• A desiccant pack can be placed in the junction box for additional humidity protection.
Notes: The above directions are for cable termination models. Hirschmann and
conduit connections require slight modications at the discretion of the installer.
Terminal Block Connections
All 206 models with terminal block connections are vented through a
porous plug on the connected; no additional venting is required during
installation.
25
3.0 Electrical Installation
The model 206 is available in the following electrical terminations:
• 2 foot cable (additional length available)
• 3-screw terminal block
• Hirschmann connector
• 1/2” conduit
3.1 Voltage Output Units
Wiring for cable, Hirschmann and conduit model 206 transducers with voltage
output is as follows:
3.2 Current Output Units
Current output model 206 are true 2-wire, 4-20 mA current output devices
and deliver rated current into an external load of 0-800 Ω. Cable termination models have a 2-wire cable where red is positive and black is negative.
On the Hirschmann connecter, pin 1 is positive; pin 2 is negative and pin 4
is the ground/shield. Terminal block units have outputs label + for positive
and – for negative, the center terminal may be used for shielding.
Note: All 4-20 mA current output units are designed to have current ow in one direction only- PLEASE OBSERVE
POLARITY. We suggest that the electrical cable shield be connected to the system’s loop circuit ground to improve
electrical noise rejection.
4.0 CALIBRATION
Every model 206 is factory calibrated and should require no eld adjustment. Whenever possible, any zero and/or span osets should be corrected
by software adjustments in the user’s control system. However, both zero
and span adjustments are accessible by removing the pan head screws and
turning the zero and span potentiometer screws inside. Pan Head screws
should be replaced after adjustment to maintain enclosure rating.
Cable & Conduit Hirschmann Pin Designation Connection to electrical system
Red#1+Excitation; connect to 12-28 VDC power supply.
Green#3+Output; connect to controller or monitor.
White#2- Output; connect to controller or monitor.
Black#2-Excitation; connect to return of 12-28 VDC power supply.
Shielding#4Connect to system or earth ground.
Note 1: Model 206 can be wired as a three wire device by connecting -output and –excitation and shield to a common
ground. However, accuracy will be reduced because of voltage drops in the leads.
Note 2: Mating Hirschmann connects #GDM3009J, Hirschmann #932214-100 with GDM3-16 Hirschmann Gasket
#731531-002 are not provided by Setra Systems, unless ordered separately as an option.
Voltage output Model 206 with a 3 screw terminal block have excitation, out-
put and common termination pouts clearly marked, wiring is as follows.
Voltage output units are factory calibrated into a 50 KΩ load. Voltage units
are operable into a 5000 Ω load or greater. The zero factory setting is ±50
mV.
Current outputs units (4-20 mA) are factory calibrated with a 24 VDC loop to
supply voltage and a 250 Ω load. The zero factory setting is ±0.08 mA. The
span (full scale) factory settings is ±0.16 mA. Zero and span adjustment are
approximately ±1.0 mA.
3
4
Loading...