No Discharge6
Insufficient Discharge6
Insufficient Pressure6
Excess Power Consumption6
7
8
9
10
11
12
ORDERING REPLACEMENT PARTS
For future reference fill in the following information from the pump nameplate.
This will be necessary to ensure accuracy when ordering replacement parts.
Model
Size
Serial Number
Material of Construction
Sethco
800 Emlen Way, Telford, PA 18969
Tel: 215-799-2577 • Fax: 215-799-0920
ww wwww..sseett hhcc oo..cc oomm •• ii nnffoo @@ss eetthhccoo .. ccoo mm
1
SETHCO WARRANTY
SETHCO
A Met -P ro Fl uid H and li ng Tec hno lo gie s Com pa ny
Thermoplastic Pumps
WARRANTY
PERFORMANCE
GUARANTEE
ACCEPTANCE
TESTS
PERFORMANCE
PRESENTATIONS
FIELD TESTING
SETHCO pumps are warranted by the Company, insofar as the same are of its own manufacture, against
defects in materials and workmanship under proper and normal use and service, for a period of one year
from the date of original shipment from the factory. SETHCO's obligation is limited, however, to furnishing
without charge, F.O.B. its factory, new parts to replace any similar parts of its own manufacture so proving
defective within said period, provided the Buyer has given SETHCO immediate written notice upon
discovery of such defect. No allowance will be made for labor charges. SETHCO shall have the option of
requiring the return of the defective material, transportation prepaid, to establish the claim.
SETHCO makes no warranty or guarantee whatsoever, either express or implied, of prime mover, starting
equipment, electrical apparatus, parts or material not manufactured by SETHCO, except to the extent that
warranty is made by the manufacturer of such equipment and material.
SETHCO assumes no liability for damages or delays caused by defective material, and no allowance will
be made for local repair bills or expenses without the prior written approval or authority of SETHCO.
Under no circumstances will SETHCO be liable for indirect, special or consequential loss or damage of
any kind and the Buyer assumes all liability for the consequences of its use or misuse by the Buyer, his
employees, or others.
Is at the specified point of rating only and will not cover performance under conditions varying therefrom,
nor for sustained performance over any period of time.
If required, shall be conducted in accordance with the practices as set forth in the Hydraulic Institute
Standards. The expense of any such tests shall be borne by the Buyer.
Are based on shop laboratory tests with cold water as outlined in the Hydraulic Institute Standards.
Due to the inaccuracies of field testing, the results of any such tests conducted by or for the Buyer shall
be interpreted as being only indicative of the actual field performance of the pump. No equipment will be
furnished on the basis of acceptance by results of field tests. If the Buyer, after such a test, questions the
performance of the pump, he may at his option request a test to establish the performance. Such tests
will be conducted in accordance with the above paragraph entitled “Acceptance Tests.”
ALL WARRANTIES
RECOMMENDATIONS
FOR SPECIAL
MATERIALS
Are void if a. Pipe strains are the cause of damage.
b. Pump handles liquids other than those specified in detail.
c. NPSH lower than required by pump impeller.
d. Operating speed is higher than specified.
e. Improper field installation.
To combat corrosion, abrasion, erosion, or pumping solids, foreign objects, or pumping liquids at elevated
temperature, any such recommendations will be based on the best available experience of SETHCO and
the supplier of the material and industry, BUT WILL NOT CONSTITUTE A GUARANTEE AGAINST
THESE EFFECTS.
The foregoing warranty is made in lieu of all other warranties guarantees, obligations or liabilities,
expressed or implied, by SETHCO or its representatives. All statutory or implied warranties, other than of
title, are hereby expressly negated and excluded.
All illustrations and provisions in specifications are descriptive and are not intended as warranties.
Penalty of any kind are not acceptable unless approved in writing by an officer of Met-Pro Corporation.
Sethco
800 Emlen Way, Telford, PA 18969
Tel: 215-799-2577 • Fax: 215-799-0920
ww wwww..sseett hhcc oo..cc oomm •• ii nnffoo @@ss eetthhccoo .. ccoo mm
2
SAFETY RULES FOR SETHCO VERTICAL PUMP MODEL ZKX
SETHCO
A Met -P ro Fl uid H and li ng Tec hno lo gie s Com pa ny
Thermoplastic Pumps
Congratulations: You have just purchased a SETHCO PUMP, a quality industrial product manufactured to exacting standards.
Thank you for choosing a SETHCO product. We look forward to serving your future requirements for quality industrial corrosion
resistant pumps and filter supplies.
To insure prolonged life of your purchase, please take time to review and understand completely the operating instructions and
become familiar with the pump before installing, filling, operating or maintaining this equipment.
INSTALLATION – OPERATION – MAINTENANCE of this equipment must be performed by trained and qualified personnel in strict
accordance with the operating instructions and all applicable drawings, specifications and codes.
Obtain, read and understand the MSDS (Material Safety Data Sheet) for the liquid being handled before installing, filling,
operating or maintaining this equipment.
Obtain instructions from the Safety Engineer responsible for your facility before installing, filling, operating or maintaining this
equipment and connected systems.
The equipment as received has been chosen for a certain application or service. DO NOT USE for any other application unless writ-
ten permission is obtained from the SETHCO factory. Consult the SETHCO factory with all of the service requirements so that we
can assist you in a successful reapplication.
Always wear appropriate protective apparel when working on or around the pumping equipment. Gloves, aprons, footwear, faceshield
and/or breathing apparatus and any other protective gear as needed for protection or as required by facility or operating
procedures.
All unauthorized personnel should be kept a safe distance from any and all work areas.
Keep hands, fingers, or tools from contacting the impeller during operation of the pump and system. Disconnect, lock and tag out
the main power source to prevent accidental start up.
Always keep face away from openings in the pump equipment. DO NOT look into hose, pump discharge or suction connections.
All auxiliary equipment such as hoses must be suitable for the chemical to be transferred. They must also be selected to safely
contain the system pressure at the operating temperature. All hose clamps must be of a material that will not be attacked by
corrosive environment or splashing of pumped liquid.
All connections should be checked for a secure liquid tight fit prior to filling and/or operating pump equipment or system.
Never turn pump on unless discharge and suction valves are open.
When connecting or wiring motor, follow all applicable electrical and safety codes.
Protect the power cable (when applicable) from sharp objects. DO NOT crimp or bind the power cable and never allow the cable to
come in contact with water, oil, grease, hot surfaces, or chemicals.
Disconnect, lock and tag out the main power source to the motor before handling the pump/motor for any reason. Lock and tag out
the switching device to prevent the unexpected application of power. FAILURE COULD RESULT IN SEVERE INJURY OR DEATH.
Avoid touching the exterior surface of the motor. It may be hot enough to be painful or cause injury.
Isolate the pump by closing suction and discharge valves prior to any maintenance. Lock and tag out the valves to prevent
accidental opening.
Do not attempt to perform any maintenance on the pump/motor unit until you are confident that the pump and its contents have been
neutralized and stabilized at ambient temperature and atmospheric pressure. FAILURE COULD RESULT IN SEVERE INJURY
OR DEATH.
Sethco
800 Emlen Way, Telford, PA 18969
Tel: 215-799-2577 • Fax: 215-799-0920
ww wwww..sseett hhcc oo..cc oomm •• ii nnffoo @@ss eetthhccoo .. ccoo mm
3
OPERATING INSTRUCTIONS FOR SETHCO ZKX VERTICAL PUMPS
SETHCO
A Met -P ro Fl uid H and li ng Tec hno lo gie s Com pa ny
Thermoplastic Pumps
GENERAL DESCRIPTION
Sethco close coupled vertical pumps are centrifugal type pumping units designed for installation inside or outside of an open
tank. All pump parts in contact with the fluid are PVDF.
PRE-INSTALLATION
All Sethco pumps are tested at the factory for proper operation. Before installing your new Sethco pump, the
following is recommended:
• Determine that the equipment checks against the packing slip for completeness of order. If there is a discrepancy, please
notify Sethco immediately.
• Inspect pump and any accessories packed with the unit to assure no damage has occurred during transit.
• Determine if any packing materials are lodged in the pump.
• Turn the impeller to determine that it is not bound. Damage to the drive motor can result from an excessive load.
PUMP INSTALLATION
WARNING: WHEN HANDLING THE PUMP UNIT, IT IS VERY IMPORTANT TO PICK UP THE UNIT BY THE MOTOR AND OR
MOUNTING PANEL ONLY.
• Your vertical pump is designed for mounting inside or outside the tank by means of the mounting panel.
• Examine mounting location for maintenance accessibility.
• Secure the unit by bolting or clamping the mounting panel in place.
• The pump shaft must be vertical to avoid damage during operation.
PIPING THE PUMP
The pump has been designed with all necessary strength factors for a long, reliable service life. However, due to thermoplastic
construction, care must be taken during installation to avoid unnecessary pipe strain. If piping strains are to be encountered,
flexible connections are recommended.
• All piping must be supported independent of the pump.
• The piping should always line up naturally. Never draw the pipe to the suction or discharge connections. Piping loads
transferred to the pump body assembly can cause damage to the pump.
• Outside installations should be compensated for changes in ambient temperature. Refer to pipe manufacturers
standards for proper installation. Omission of this can result in severe strain transmitted to the pump body assembly.
• If expansion joints are used, they should be installed in a location to prevent loading of the pump connections.
• Piping should be as short and direct as possible. Avoid all unnecessary elbows, bends and fittings, as they increase
friction losses in the piping.
DISCHARGE PIPING
Installation of a valve in the discharge line, that can be used as a flow shutoff for inspection and maintenance, is recommended. It should be of a design to allow throttling or flow control. The diameter of the discharge valve should be as large or
larger than the pump discharge.
SUCTION PIPING
When the unit is mounted outside the tank, the pump inlet should be kept as short as possible, with minimum restrictions, for
easy priming and proper operation. Inlet piping should be at least as large as the pump inlet.