Server CP-10 Service Manual

Stainless Steel Pump
for use with food containers
MODELS INCLUDE:
SP SP-3 CP-G CP-3 CP-10 TP
Thank You
...for purchasing our Stainless Steel Pump. This quality NSF listed pump delivers precise portions and lasts for years of service.
CONSISTENT PORTIONS—SERVE BETTER
Your pump may vary
depending on specific
model number.
PUMP PARTS
PORTION CONTROL
PLUNGER ASSEMBLY
KNOB*
(black knob:
82023-000)
LOCKING COLLAR*
HEAD TUBE
82017
HEAD INSERT
82018
SPRING*
WASHER
82015
PISTON
82013
SEAL ASSEMBLY*
PUMP DELIVERS 1 FL OZ PORTIONS
To reduce portion, add
GAGING COLLAR(S)*
83529 SM COLLAR: 1/8 fl oz reduction
82022 LG COLLAR: 1/4 fl oz reduction
COLLAR(S) USED PORTION RESULT
None 1 fl oz 1 Sm 7/8 fl oz 1 Lg 3/4 fl oz 1 Lg + 1 Sm 5/8 fl oz 2 Lg 1/2 fl oz 2 Lg + 1 Sm 3/8 fl oz 3 Lg 1/4 fl oz 3 Lg + 1 Sm 1/8 fl oz
FOOD EQUIPMENT LUBRICANT
40179
BRUSH
82049
BRUSH
82526
LID*
DISCHARGE TUBE*
DISCHARGE TUBE NUT
82027
O-RING, 1"
05127
CYLINDER*
O-RING, 1-5/16"
82323
VALVE BODY*
Page 2
MODEL NUMBER
*Parts may vary depending on specific model.
Pump model, P/N (part number) and other identification are often stamped on lid:
MODEL XXXX P/N #####
For additional details about your pump, visit www.Server-Products.com
Enter your P/N into the search bar.
SERIES ##X ##X
SAFETY
According to food and safety regulations, most foods must be stored and/or served at certain temperatures or they could become hazardous. Check with local food and safety regulators for specific guidelines.
Be aware of the product you are serving and the temperature the product is required to maintain. Server Products, Inc. cannot be responsible for the serving of potentially hazardous product.
PUMP CLEANING
FLUSH & RINSE
1
all pump surfaces with hot water.
Place lower end of pump into container of hot water and operate pump until all remaining product is expelled and only hot water is discharged.
DISASSEMBLE & CLEAN
2
all washable parts with soap and hot water. (See DISASSEMBLY on page 5.)
USE SUPPLIED BRUSH
to thoroughly clean inside discharge tube and any confined areas.
IMPORTANT
Clean, rinse, sanitize, and dry parts daily or regularly to comply with local sanitization requirements.
NSF International lists this pump as “Not acceptable for dispensing potentially hazardous foods.”
Pumps 81196, 81320 & 94080 are NSF listed as part of a complete unit.
YES!
Use dishwashing soap, hot water and nylon brush.
Pump is dishwasher safe.
RINSE
3
fully with clean water.
SANITIZE
4
all parts according to local sanitization requirements. All parts in contact with food must be sanitized.
AIR DRY
5
all parts fully.
Page 3