Serta Motion Essentials Owner's Manual

Motion Essentials
Owner’s Manual
Actual product appearance and functionality may vary from photographs, illustrations and descriptions included in this manual.
table of contents
Safety Precautions and Usage Statements ...........................................................1-4
Parts List ....................................................................................... 5
Base and Remote Overview .........................................................................6
Quick Reference Guide ............................................................................7
Installation Guide ...............................................................................8-9
Battery Backup Strap .............................................................................10
Pair Remote .....................................................................................11
Connecting Strap ................................................................................12
Syncing Two Bases ...............................................................................13
Headboard Brackets (not included) ...............................................................14-15
Troubleshooting ..................................................................................16
Español ..................................................................................... 17-21
Français ..................................................................................... 21-25
safety precautions and usage statements
Attention: Important Safety Disclaimers
Read all instructions before using your adjustable base. Save these instructions.
failure to use a wall outlet or surge protector could void the electrical portion
WARNING
of your warranty.
Always unplug the base from the electrical outlet before servicing any
part of the base. To reduce risk of electric shock, unplug the base before
cleaning. To safely disconnect, ensure the base is in a flat position with all
motors o, and unplug from power source.
SAFETY
TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY For optimal safety and operation, plug bed base into a surge protector (not included). The bed base should only be plugged directly into a wall outlet or surge protector (strongly recommended). Always unplug the base from the electrical outlet before servicing any part of the base. To reduce risk of electric shock, unplug the base before cleaning. To safely disconnect, ensure the
base is in a at position with all motors off, and unplug from power source.
Keep the power cord away from heated surfaces. Never operate the base when the air openings are blocked. Keep air openings free of lint, hair and the like. Do not drop or insert any object into any opening. Discontinue use
of the bed base and contact a qualied service center if: it has a damaged
cord or plug, if it is not working properly, or it has been dropped into water. Only use this bed base for its intended use as described in this manual. Do not use accessories/attachments that are not recommended by the manufacturer. Close supervision is required when the bed base is used by or near children, convalescents, disabled persons or pets. Improper connection
of the equipment can result in the risk of electrical shock, electrical re or faulty operation of this bed base. If the plug does not t your outlet, contact a qualied electrician to install a suitable outlet. Unauthorized modication or
WARNING
Keep bed in a flat position when not in use.
Stay clear of moving parts while in motion.
Before adjusting, make sure children and pets are clear of moving parts and are not under bed base.
Do not allow children to operate bed base without adult supervision
PETS AND CHILDREN Immediately dispose of all packing materials as it may pose a smothering risk to small children and pets. To avoid injury, it is not advised to allow children and small pets to play on or under the bed. Children should not operate the bed base without adult supervision.
PACEMAKERS Some products contain Neodymium MAGNETS, which may interfere with devices such as pacemakers, ICD’s and any other device sensitive
to magnetic elds. It is STRONGLY recommended that owners of such
medical devices consult their physician prior to using products that contain Neodymium MAGNETS. It is also possible that some pacemakers may falsely interpret the optional massage feature vibrations as movement/exercise. This is a common occurrence with any product that creates a vibrating movement and may not affect the pacemaker. Please consult your physician before using the massage feature.
1
Adjustable
Bed Tolerance
IN-HOME USE AND HOSPITAL STANDARDS Ergomotion adjustable bed bases are designed solely for in-home use. This base was not designed as a hospital bed and is not designed to meet hospital standards. Do not use this base with TENT TYPE oxygen therapy equipment or near explosive gases.
WARNING
For optimal safety and operation, plug bed base into a surge protector
(not included). The bed base should only be plugged directly into a
grounded wall outlet or surge protector (strongly recommended). Improper
connection of the equipment can result in the risk of electrical shock,
electrical file or faulty operation of this bed base. If the plug does not fit
your outlet, contact a qualified Electrician to install a suitable outlet.
ADDITIONAL SAFETY FEATURES Casters (optional leg accessory) are equipped with locking wheels to prevent unwanted movement. Even when locked and unable to roll, it is possible for the casters to slide. Free release head and foot motors are designed to lower the mattress by retracting only with gravity, never pulling downwards, which
minimizes pinch points.
ACOUSTICS
LIFTING/LOWERING MECHANISMS The lift/lower feature will emit a minimal humming sound during operation. This is normal. During operation, the lift arm wheels make contact with the platform support of the base. This contact may result in metal on metal or metal on plastic contact. This applies slight tension on the moving components and resonance is reduced to a minimum level. If excessive noise or vibration is experienced, reverse the movement action (up or down) of the base with the remote control. This should realign the base’s activating mechanisms to the proper operational position. In normal base operation, the
wheels, which allow the bed to maintain its distance from the wall, will make contact with the steel platform supports of the base creating a contact noise. When entering, exiting or shifting weight on the base, this contact noise may be audible as the wheels make contact. This is normal.
MATERIALS Ergomotion adjustable bases are constructed from various materials including woods, metals, plastics and fabrics. Tension, pressure or movement applied to the frame, platform or shroud through general use may create an audible sound.
TOLERANCE
(α°)
(β°)
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during the quality control process to ensure bases will operate within these
standards during normal operating use. Normal operating use is dened
as the following: Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle tests with up to 120 kg
distributed load. The angle (designated “a” in gure 1) between the back section and the at section for various congurations of the mattress support
platform shall be ± 3°, which translates to a tolerance of up to 1 ½”.
2
The angle (designated “b” in gure 1) between the at section and foot section for various congurations of the mattress support platform shall be ± 3°,
which translates to a tolerance of up to ¾”.
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer’s quality control standards.
THAT “NEW PRODUCT” SMELL Some people notice a slight odor to their new adjustable base. This can come from our material manufacturing process and the smell normal and usually disappears before the product reaches you. Sometimes, however, this smell may still be noticeable. It usually disappears after a few weeks, providing adequate ventilation of the product and the environment.
BREAK IN PERIOD You can speed up the break-in period by simply spending time in the adjustable bed through activities such as reading, watching TV or playing with the kids or grandkids. The extra movement will help the adjustable base respond to weight and temperature changes. Some of the materials in our adjustable bases such as the woods, metals and plastics used in the platform, frame and components are sensitive to moisture content and temperature and may make sounds in colder environments.
PAIRED OPERATION When operating a “paired” split base setup there may be a time latency up to
1.5 seconds between each bases articulation.
For spot cleaning, wipe area with a light damp sponge or vacuum with a soft brush attachment to remove particles. Keep at a minimum of 30 cm (12 inches) away from direct heat sources. For a deeper cleaning, blot liquid spills with a clean dry cloth. Wipe with a clean cloth dampened with warm water. Do not wet excessively. A soft bristle brush may be used to remove ingrained soil. Avoid scratching by gentle brushing. Wipe with a clean cloth dampened with warm water to remove residues. Dry in shade away from direct heat. If persistent marks remain visible after cleaning, seek professional advice.
PRODUCT RATINGS The lift motors are not designed to operate continuously for more than two (2) minutes in an eighteen (18) minute time period or approximately 10% duty cycle. Attempting to circumvent or exceed this rating will shorten the life expectancy of the product and may void the warranty.
WEIGHT LIMITS This product is not rated to support weights in excess of 650 pounds inclusive of the mattress and bedding. The base will structurally support this weight, provided it is evenly distributed across the bed base. The adjustable base is not designed to support or lift this amount in the head or foot sections alone. Exceeding this weight restriction could damage the bed and/or cause injury and will void the warranty.
WEAR AND TEAR Wear and tear is damage that naturally and inevitably occurs as a result of normal use or aging.
FABRIC CARE To prolong the life of your fabric, protect from direct sunlight whenever possible.
3
IMPORTANT DO’S AND DON’TS
DO:
Plug your adjustable base into a power surge protector.
Evenly distribute weight when sleeping in a split setup (uneven distribution of weight can cause the base to lift unevenly).
Call Customer Service for any technical issues. Do not try to force the base down (this can damage the motors or frame).
Use mild soap and water to clean your adjustable base if staining occurs.
Keep in mind that adjustable bases are recommended to be used with adjustable friendly mattresses.
Lower to the at (horizontal) position after use and in between presets.
Enter or exit your adjustable in the at (horizontal) position.
Register your warranty as soon as your adjustable base has been delivered.
DON’T:
Sit on corners/edges of base (this may warp the frame, struts or foam).
Tilt the base on its side (this can damage the legs and/or leg screws).
Stand or jump on the adjustable base at any time (this can damage the frame and motors).
Drag the base to move it. Purchase castors if you plan on moving your base routinely. (Dragging the base could damage the frame, strip the nut/ bolts or break the legs.)
Enter and exit the adjustable base with the head and/or foot in the articulated position.
Tinker with or modify base.
Press down on the head or foot while actuated, this can damage the frame and motors.
FCC Compliance:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirement and void user’s right to operate the device.
Radio Frequency: 2.4 GHz
4
parts list
Before discarding the packing materials, ensure all the parts are accounted for.
All electronics and components that need to be installed are located in boxes under the base or attached to the frame.
A) Wireless Remote Control and AAA Batteries (3) B) Mattress Retainer Bar* C) Legs (4) and Leg Washers (4)
D) Power Cord E) Power Supply F) Battery Backup Strap G) Connecting Strap‡
H) Sync Cable I) Manual J) Warranty Card K) Quick Setup Guide
Misc. Parts (not included):
Headboard Brackets Surge Protector 9-Volt Batteries (2)
* These items are attached to the base for shipping purposes. Carefully remove from
base and set aside.
‡ Only included in Twin Long and Cal King Split Bases.
A) B)* C)
D)
G)
E) F)
H)
I) J) K)
5
base and remote overview
Head Massage
Head Motor
USB
Lifts and lowers
head portion of
the base.
Flat position
Lifts and lowers foot portion of the base.
Massage
Control Box
Foot Motor
6
quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
ELECTRONICS OVERVIEW
Wireless
Remote
Battery Backup Strap
Massage Motor
Port
USB
Power Cord
If installing a split unit, see pages 12-13
Input Cord
Power Supply
Control Box
Head Motor
Foot Motor
7
Loading...
+ 19 hidden pages