SereneLife SLNKMSG131 User guide

Page 1
Questions? Issues?
We are here to help!
Phone: (1) 718-535-1800
SLNKMSG131
Smart Neck Massager
Digital Massager with Heat Therapy,
Built-in Rechargeable Battery
Page 2
PLEASE READ THIS MANUAL CAREFULLY
AND KEEP A COPY HANDY FOR FUTURE REFERENCE.
PRODUCT INTRODUCTION
The SLNKMSG131 neck massager, with a streamline ring design in consistence with human neck physiological curvature, forms a composite energy eld directly acting to deep tissues and marrow, with multi-channel synchronous massage in modes of low-frequency electric impulse, magnetic action, thermal moxibustion, ring traction. Throughout its operation, it could make the user keep a proper physical body posture, giving a scientic platform for the proper care on cervical vertebra diseases, with which you could give yourself enjoyable and value-added multi-functional systematic health care at home!
SCOPE OF APPLICATION
It could promote local blood circulation, relax local muscles and relieve fatigue, so it is applicable to health care and relief on neck pain, shoulder and arm numbness, headache and dizziness.
PRODUCT FEATURES
• Nice-looking and scientic ergonomic design, tting human neck curve;
• Its adoption of the latest 3D intelligent tting technology could realize easy
adjustment on electrodes according to your neck curve, giving you more
comfortable experience of use;
• Synchronous action in ve modes of thermal moxibustion, low-frequency electric
impulse, magnetic eect, ring traction and red light to form an ecient composite
energy eld;
• The thermal moxibustion could warm and activate meridians, dispel dampness
and dissipate cold, which works in 3 temperature levels of High Medium and Low. You could select the level according to your own demand and the ambient
environment;
• Two automatically combined electric impulse modes and four manual electric
impulse modes to meet dierent demands, thus being applicable to more
people;
• Several built-in magnets to promote the microcirculation;
• Provided with a remote control and LCD menus and backlight display for easy and clear operation, thus being more humanized.
2
3
Page 3
HOW TO OPERATE
How to operate power supply
1. Charging of the built-in rechargeable battery.
The built-in rechargeable battery can serve as the power supply when the external power supply is not used.
2. Power supply with the built-in rechargeable battery (applicable to rechargeable ones) When it is not used as an external power supply, it could be used for power supply.
FUNCTIONS
1. Shift the toggle switch to "ON" position and then apply the massager close to
your neck; if there is some sweat on your neck, please clear them before use.
2. Hold the remote control and press the button " " to boot it; after you hear the
buzzer beeps once, the power supply indicator will be on and the default
program is enabled. The massager will work under Impulse Mode 1, Intensity 01
and Level 2 of thermal moxibustion, with the default time period of 15 minutes;
now you could use the remote control to adjust to the massage mode and
intensity you desire.
3. Press the " " pulse mode button to select 1-6 mode, 0 is the stop mode.
The "+" button is to increase the intensity, with one level increase for each time
of pressing it; the "-" button is to decrease the intensity, with one level decrease
for each time of pressing it. There are 16 levels for adjustment.
The default level is level 1 when booting.
4. The button " " is to select the thermal moxibustion mode. And the "0" means
stopping thermal moxibustion, while the "1" means low temperature and the
"3" high temperature. It defaults to "2" when booting.
5. After the massage is completed, please shift the toggle switch to "OFF" position
to power off the massager; then, stick the electrode slices on the storage board
for storage in a dry, well-ventilated place for next use.
6. When the battery runs low, please charge it with the power adapter provided
for the massager; otherwise, the massager will be off automatically after the
indicator ickers for alarm.
7. When the remote control backlight ickers or becomes insensitive, it is
recommended to replace the button battery (3V, CR2032 type, and others are
not allowed); the normal service life of the battery is more than three months.
Attention: When you use the remote control to operate the massager, the IR
receiving window on the massager and the IR sending window on the remote
controlcannot be shielded; furthermore, please aim the remote controlat the
receiving window as much as possible to get the best sensitivity.
4
5
Page 4
USE OF SILICON ELECTRODE SLICES
1. Insert one end of the 2-core connector wire into the electrode port and connect
the other end to the electrode slices; then use the massager as specied above.
If they are used together with the conductive plates, there will be a little
dierence in intensity due to the parts they are applied are dierent, which is
normal.
2. The electrode slices should be clean on their surfaces without any dust, oily or
sticky substance; otherwise, the viscosity will be reduced. If their surfaces become
dirty, please ush with clean water and then dry them in the air for repeated use.
3. The electrode slices could be used for about 80 times (20 minutes for each time).
If their viscosity still cannot be recovered after several times of cleaning, please
consider to purchase new ones from your local dealer or the manufacturer.
4. Only the electrode slices provided for the massager, each with a size of 55mm
wide, 80mm high and 2.5mm thick, could be used; and others are not allowed.
5. Please dispose the waste electrode slices according to your local environmental
regulations rather than discarding them at will. It is recommended to use the
massager for one to two times a day, 10 to 20 minutes every lime of massage in
electric impulse mode and 15 to 30 minutes every lime of thermal moxibustion.
ATTENTIONS
1. Never use this massager with other electronic medical devices such as heart
pacemaker, articial heart-lung machine used to sustain lives, electro-
cardiograph, etc., or a danger will be led to. If the patient is being treated with
high frequency surgical equipments and this massager, it is likely to give rise to
a bum at this massager's electrode or damage it; if it is used near short-wave or
microwave therapeutic equipments (1 meter), it will be possibly unstable in output.
2. This massager cannot be used for pregnant women and those with sensitive skin, heart disease, abnormal blood pressure, malignant tumor, cerebral vascular disease, acute disease or others under treatment before consultation with the doctor.
3. Prohibit using it in bathing or sleeping.
4. Please don't use it for children or those with expressible consciousness disability.
5. Never use it for those with skin consciousness disability or not sensitive to heat.
6. Don't move this massager during use; in changing the massage area, please power it off rst and then reuse it; otherwise, a serious irritation will be caused.
7. It is suitable to adjust the impulse intensity to an acceptable level.
A higher intensity doesn't always lead to a better result of massage.
8. Please don't make unauthorized disassembly on this massager and please
avoid any collision, water penetration into it, or a trouble will be caused.
9. Prohibit cleaning this massager with water.
CHARGE THE BATTERY
• When the buzzer beeps for continuous three times during massage, it indicates
the built-in lithium battery runs low and needs charging with the USB charging
cable. Then, shift the toggle switch to "Charge" position, with the power indicator
turning green and ickering. When it is fully charged, the power indicator keeps
green. It will last about 3 to 4 hours to fully charge the battery.
• The battery could be used for about one week (30 minutes a day) after full
charging.
• Under normal use, the rechargeable battery supports 500 times of charging and
discharging at least and could be used for about 2 to 3 years (use twice a day and
30 minutes at most every time). When it is not in use for a long lime, please
charge it once a month at least to prevent reducing its service life.
6
TROUBLESHOOTING AND SOLUTIONS
Fault Possible Cause Solution
The massager
fails to boot.
Check if its toggle switch
is shifted to "ON".
Check if the remote
control display is on.
Check if the built-in
rechargeable
battery runs low.
Low battery
Please shift its toggle
If no display, please replace the
CR2032 button battery in the
remote control with a new one.
If it runs low, please charge it.
Check if the USB charging cable
is plugged in. The massager
charging indicator will ash.
switch to "ON".
7
Page 5
Fault Possible Cause Solution
The massager
cannot be
charged or has
no display in
charging.
It displays
normally but
no response
or stimulation
could fell.
There is a sense
of tingling
Check if the USB charging
cable is properly connected.
Check if the toggle switch
of the massager is shifted
to "Charge" position.
Check if the electrode
slices contact close to your
neck skin.
Check if there are some hairs, cloths, accessories, etc. at the contact area of electrode slices and your skin.
Check if the massage
intensity is adjusted.
Check if the electrode slices
contact close to your neck skin.
Check if the massage lasts too
long.
Check if the massage intensity
is too high.
Check if your skin is allergic to
electrode slices. The cold weather causes your skin dry.
Insert the plug of the power
adapter properly.
Conrm its toggle switch is
shifted to "Charge" position.
The electrode slices must
contact close to your neck skin.
Please remove or separate such objects.
The intensity is defaulted to Level 0 when booting and needs adjusting; or some users are not
sensitive to the intensity in Level 1 to 2 and could increase the intensity properly.
Wet your neck skin with a wet towel rst and then contact the electrode slices close to the skin, and then adjust properly the intensity and massage mode.
It is suitable to massage for 10 to 20 minutes every time and not to
exceed twice a day.
Properly reduce the intensity.
Check if your skin has a history of allergy. If slight, please reduce the massage time; if serious, please
stop using the massager and then seek for desensitization treatment. Wet your skin and the surface of electrode slices with a wet towel.
Fault Possible Cause Solution
Use the massager after
staying up late.
There is no
sense of tingling.
The stimulation
felt is weak.
Check if there are some
hairs or accessories at the contact area of electrode slices and your skin.
Check if your neck skin
contact close to electrode slices.
Check if there is some dirt
or oil stain on electrode slices.
Check if the rechargeable
battery runs low.
Check ifthere is a serious
A red mark is left after use.
sense of tingling or if some other unguent is applied during use of the massager.
Please use it the next day as the electrolyte reduces after staying up late.
Please remove or separate the accessories or hairs.
Contact them close to your
skin and then adjust properly the intensity.
Clean their surfaces.
If it runs low, please use an
external power supply to supply the power.
Please stop using the massager and the red mark will disappear
in 3 to 5 days generally.
CLEANING AND MAINTENANCE
1. Use a wet soft cloth or towel to wipe the massage, with the volatile agents not allowed.
2. Store it in a dry and well-ventilated place.
3. DO NOT store it in a place with direct sunlight, high temperature or moisture.
WARM PROMPTS
1. In using the massager, please shift the toggle switch to "ON" rst and then aim the IR sending window on the remote control at the IR receiving window on the massager. lf the rechargeable battery built in the massage runs low, please charge it with a power adapter. If the remote control cannot work normally, please replace the button battery (CR2032) inside it.
2. In charging, please use a power adapter and then shift the toggle switch to
"Charge".
8
9
Page 6
Features:
Digital Neck Massager System
•
• Matt & Fashionable Wrap-Around Style
• Portable Design, Perfect for Travel
• Relieve Stress, Excess Tension Improve Blood Circulation
• (6) Selectable Preset Massage Modes with Timer Settings
• Simple & Hassle-Free Operation
• Built-in Rechargeable Battery
• Remote Display for Wireless Control
• Includes Wireless Controller, Easy to Operate
• Extended Electric Pads to Massage Any
• Universal Size for All Ages
• Red Light Function, 630-650mm Wavelength to Increase Energy Supply
• Dual-Band Output Electric Massage
• Far Infrared Heating with 3-level
What’s in the Box:
Neck Massager
•
• Remote Control
• Electronic Pads and Cable
• Back-Up Button Battery for Controller
• Power Cable
Technical Specs:
Intensity Level Selectable: Electric Modes (6), 16 Level Intensities,
•
3 level Heat ON/OFF
• Adjustable Time Settings: 15 Minutes
• Massage Impulse Width: 20-400μs
• Electric Pulse Freq.: 1-1000Hz
• Rechargeable Battery: 3.7V Li-ion, 1500mAh
• Charger Type: USB-C (Type C)
• Remote Control Battery: (1) x ‘CR-2032’ Button Cell, Included
• Back-Up Button Battery Type: CR-2032
• Electronic Pads Cable Length: 3.94 ft.
• Power Supply: 5V DC 1000mA
• Massager Controller Dimensions (L x W x H): 4.61’’ x 1.69’’ x 0.47’’ -inches
• Product Dimensions (L x W x H): 6.34’’ x 5.63’’ x 2.17 ’’ - inches
10
11
Loading...