SZ-PIR04N ZigBee Motion Detector Installation Guide
0 C to 50 C (32° - 122°F)
-20 C to 65 C (-4° - 149°F)
5 Years (Assume 30 events per day @25°C)
Distance: Max. 15M (±1M) w/mounting height 1.8M @25°C
Angle: Max. 90 (±10) Degree
SZ-PIR04N is a PIR (Passive Infrared) sensor, which can detect levels of infrared radiation from objects in its range of view. This
Motion Detector is fully compatible with any ZigBee coordinator that are HA 1.2 certified.
It is also a pet immune motion sensor, which is used to ignore the motion caused by animals and thus reduce the likelihood of false
alarms. The sensitivity of the sensor will disregard the motion caused by animals under 85 pounds, like a full-grown dog or small
cats.
In addition, the SZ-PIR04N has walk test mode and white light immunity, which can be used to reduce false alarms caused by
lights, flashlights or other reflective objects. These outstanding features of the sensor provides the professional security for
protecting any home or business to save time, money and deliver a great surveillance experience as well.
Specification
Package Contents
Intallation
1. Detach the mount bracket from the device.
2. Install the provided batteries correctly.
3. Attach the mount bracket back to the device.
1
Operation
5. Battery Cover (Wall
Mount Bracket)
When the batteries are installed, the PIR LED will be blinking for 30 seconds and then turn off when the Motion Sensor is
ready to be used.
After the tamper switch is pressed, the Motion Detector will be in normal mode. The PIR LED on the device will illuminate
when the Motion Detector is triggered.
The motion sensor needs to be checked and perform walk test annually to make sure the detection function is working
properly.
Adding to a ZigBee Network
Join Function
After installing the batteries, the Join/Leave (Green) LED will start blinking every 5 seconds which indicates SZ-PIR04N
is ready to join a ZigBee network.
The device will attempt to joing a ZigBee network for 20 times (100 seconds). If all attempts fail, SZ-PIR04N will stop
joininig process, and need to press and release the tamper again to start joinging process.
Leave Function
For “Leave” a network, please do the following instruction:
Press and hold the tamper switch while installing the batteries.
Release the tamper switch within 4 seconds and the device will be reset to factory default.
Walk Test
1. Remove the batteries and adjust the “Walk Test Switch” setting to “On” to enable “Walk Test”.
2. Install the batteries and rearm timer will be configured to 5 seconds for installers to test the detection coverage.
3. Remember to adjust the switch setting back to Off (normal mode) after walk test finished to save battery power.