SZ-ESW02N, SZ-ESW02, SZ-BSW02N Power on/off Switch Installation
15A Resistive / 400W Incandescent
-20° - 70°C (-4° - 158°F)
Over voltage protection & Over current protection
On (Green) - Power On.
Blinking (Green) - The join function is being processed.
This is an electrical power measuring device, which is compatible with ZigBee enabled devices with its embedded radio
frequency (RF) technology. It can also be used with other devices with the ZigBee logo regardless of the manufacturer.
Furthermore, it can work as a signal repeater that will extend the wireless transmission range and increase the reliability of your
network. With a ZigBee compatible gateway and software program, you’ll be able to monitor and inform the energy usage of the
connected appliance.
Specification
Packag
e Contents
SZ-ESW02(N) or SZ-BSW02N
ZigBee Energy Switch Installation & Operation Manual
Guide
Warnings and Cautions
•
Please install and/or use in accordance with appropriate electrical codes and regulations.
•
If you are unsure about any part of these instructions, please consult a qualified electrician.
•
To reduce the risk of overheating, do not install the device near heat sources, such as fires, boilers or heating vents.
•
Do not locate the device facing direct sunlight or humid place.
•
This instruction sheet contains important technical data. Please keep it for future reference.
LED
Installation
NOTE: In order to use SZ-ESW02(N) or SZ-BSW02N in a ZigBee network, the device must be connected to the network via
ZigBee coordinator. Please refer to the instruction sheet for complete information.
1. Put the SZ-ESW02(N) or SZ-BSW02N into a wall receptacle. Make sure the receptacle is working properly. If it is
controlled by a wall switch, please ensure it is set to ON all the time.
2. Attach the appliance to the SZ-ESW02(N) or SZ-BSW02N.
SZ-E(B)SW02(N) V0.4
1. On/Off and Pairing Button
2. On/Off , Pairing and alarm LED (Green)
Operation
MANUAL Operation:
•
ON/OFF: Press this button of the device to turn the appliance on/off.
NOTE: The appliance will be turned Off regardless of its previous setting.
Join / Leave Function
Auto Joining State: A sensor that does not have a network shall search for a network that is open for joining.
1. Illuminate the LED indicator for 2 seconds to indicate a successful boot.
2. The sensor should resume scanning the next time a user-trigger occurs. This allows user interaction to cause the sensor to
resume scanning.
Joined State: A sensor that has joined shall resume the network.
1. Illuminate the LED indicator for 2 seconds to indicate a successful boot.
2. Resume operation with the existing network.
Manual Defaulting: Default a sensor puts it into a state where it is ready to be joined to a coordinator.
The process for manually default a sensor shall be as follows:
1. With the sensor powered down, press the button and hold it.
2. Power it up again. The sensor should illuminate the LED once all boot up/initialization tasks are complete.
3. Release the button while the LED has been illuminated (in 4 seconds).
4. The sensor shall then wipe any knowledge of the previous network and other configuration parameters and begin searching
for a new network(Auto Joining State).
Troubleshooting
If the device appears to be functioning improperly, please follow the suggested steps:
1. Confirm that the device is being supplied from a 120V power source.
2. Confirm that the device is being controlled in a proper way (local switch is ON).
3. Ensure that the appliance does not exceed 15A current.
SZ-E(B)SW02(N) V0.4