SW-PIR03N Z-Wave Motion Sensor Installation Guide
0 C to 50 C (32° - 122°F)
-20 C to 65 C (-4° - 149°F)
2 Years (Assume 30 trigger events per day @25°C)
Distance: Max. 15M (±1M) w/mounting height 1.8M @25°C
Angle: Max. 90 (±10) Degree @25°C
SW-PIR03N is a PIR (Passive Infrared) sensor, which can detect levels of infrared radiation from objects in its range of view. This
Motion Detector is fully compatible with any Z-Wave controller and can be operated in any Z-Wave network with other Z-Wave
certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of
vendor to increase reliability of the network."
It is also a pet immune motion sensor, which is used to ignore the motion caused by animals and thus reduce the likelihood of false
alarms. The sensitivity of the sensor will disregard the motion caused by animals under 85 pounds, like a full-grown dog or small
cats.
In addition, the SW-PIR03N has walk test mode and white light immunity, which can be used to reduce false alarms caused by
lights, flashlights or other reflective objects. These outstanding features of the sensor provides the professional security for
protecting any home or business to save time, money and deliver a great surveillance experience as well.
Specification
Package Contents
Installation
1. Detach the mount bracket from the device.
2. Install the provided battery correctly.
3. Attach the mount bracket back to the device.
1
Operation
6. Battery Cover (Wall
Mount Bracket)
Remove the protection film on front panel before installation.
When the battery is installed, the PIR LED will be blinking for 30 seconds and then turn off when the Motion Sensor is ready
to be used.
After the tamper switch is pressed, the Motion Detector will be in normal mode. The PIR LED on the device will illuminate
when the Motion Detector is triggered.
When the Motion Detector is triggered, it will send Basic Set ON (0xFF).
If no movement detected in three minutes, it will send Basic Set OFF (0x00).
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTED TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
Add (Inclusion) Sensor
For adding in (Inclusion) a network: Put the Z-Wave controller into "Add (Inclusion)" mode, and follow its instruction to add
SW-PIR03N to your controller. This sensor needs to be included before installation.
1. Install the battery and the Pairing LED indicator will be lit for one second to indicate a successful booting.
2. It will blink one time every second while scanning the network.
3. If the network is not found after 30 seconds, the sensor will go into sleep mode. To wake the sensor again, you need to use the
tamper switch to trigger the adding (Inclusion) process, and then the sensor will repeat steps from 2 to 3.
Remove (Exclusion) Sensor
1. Set the Z-Wave controller to "Exclusion" mode.
2. Press the tamper button 3 times within 2 seconds.
3. The PIR LED will light up for 1 second if success.
4. The device will begin to search for a new network.
Association
Associations (Association Command Class Version 2)
This Sensor supports 2 association groups. This has the effect that when the sensor is triggered, all devices associated with the
sensor will receive the relevant reports. Through an association the sensor may control another Z-Wave network device, e.g. a
alarm device, wall plug, lamp etc.
Every group can be support to associated 5 devices max.
GROUP 1 is lifeline service that assigned to Sensor (Motion detector) status – Open/Close. It enables the sensor to send reports
and readings to a Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered. This Group Support:
NOTIFICATION_REPORT_V4
DEVICE_RESET_LOCALLY_NOTIFICATION
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
BATTERY_REPORT
GROUP 2 allows for Sending Basic to associated devices in this group. This Group Support:
BASIC_SET
Reset to Factory Defaults
1. Press the tamper switch 4 times within 2 seconds and hold the 4th press until the PIR LED lights up.
2. The PIR LED will be off after 3 seconds and all settings will be reset to factory defaults.
Walk Test
1. The PIR will be in “Walk Test” mode for 3 minutes after install the battery. After 3 minutes, the PIR will return to normal
operation mode if the “Walk Test” jumper is not installed.
2. If the installer needs longer time to perform walk test, install the “Walk Test” jumper and the PIR will NOT return to normal
operation mode.
3. Rearm timer is configured to 2 seconds for walk test and 3 minutes for normal operation mode.
4. To save the battery, remember to remove the jumper after walk test finished.