Sercomm SWESW01N Users Manual

SW-ESW01N, SW-BSW01N Z-Wave Binary Switch Installation Guide
SW-ESW01N is a powered Z-Wave Plus electrical power measuring device, which is compatible with Z-Wave Plus enabled devices, regardless of the manufacturer and can also be used with other devices with the Z-Wave logo. If device is not part of Z-Wave network, with auto network add, the device will activate add process as soon as the device is powered on. The user can also manually activate add process by pressing the On/Off button. Once it is included into a Z-Wave network, SW-ESW01N can also act as a repeater in the network.
Specification
Frequency 908-916 MHz Operating Temperature Temperature: 0° - 40°C (32° - 104°F); Humidity: 0% - 80% RH (non-condensing) Storage Temperature Temperature: -20° - 70°C (-4° - 158°F); Humidity: 0% - 90% RH (non-condensing) RF Communication Range Open Air: 80M (Max.) LED Indicator LED x1 Power 120VAC Operating Voltage 120V / 60Hz Max Load 15A Resistive / 400W Incandescent Over Voltage Protection(OVP) 132V (126V resume) Over Current protection(OCP) 15.5A Dimensions (H x W x D) 55mm x 55mm x 37.5mm Compliance FCC, UL ,Z-Wave plus
Package Contents
SW-ESW01N
Z-Wave Binary Switch
Warnings and Cautions
To be installed and/or used in accordance with appropriate electrical codes and regulations. If you are unsure about any part of these instructions, please consult a qualified electrician. To reduce the risk of overheating, do not install near heat sources, such as fires, boilers or heating vents. Do not locate the device facing direct sunlight or humid place.
1 SW-ESW01N QIG V0.5
Save this instruction sheet. It contains important technical data, which will be useful for future reference.
Operation
1. On/Off and Pairing Button 2. On/Off , Pairing and alarm LED (Green)
Installation
1. Put the SW-ESW01N into a wall receptacle. Make sure the receptacle is working properly. If it is controlled by a wall switch,
make sure it is set to ON all the times.
2. Attach the appliance to the SW-ESW01N and make sure the load does not exceed 15A
Device Functions
The table below summarizes Z-Wave related functions supported by the energy switch.
Function Description
1. Put the Z-Wave controller into "Add (Inclusion)" mode.
2. Power on the device.
3. The LED is blinking while scanning the network and. This process may
Add(Inclusion)
Remove(Exclusion)
Reset to Factory Defaults
Meter
*LED will be blinking quickly every 0.1sec, if OCP(Over Current Protection) or OVP(Over Voltage Protection) kick in. Otherwise, the blinking speed will be normal every 0.5sec.
take up to 30 seconds. (In the meanwhile, our device will send its NIF.)
4. If the add process is successful, the LED will turn off and restore to relay state.
If the process failed, press the On/Off button once and the device will be in auto add mode again.
1. Set the Z-Wave controller to "Remove (Exclusion)" mode.
2. Press the On/Off button three times within two seconds.
3. The LED will be blinking for one second.
NIF.)
Note 1: if the Remove process is successful, the node ID will be cleared and the device will be in auto add mode.
Note 2:Relay state default off
1. Press the On/Off button 4 times within two seconds and hold the 4th press until the
LED lights up.
2. The LED will turn off after three seconds. The node ID will be cleared and all
settings will be reset to factory defaults.
3. The device will be in auto add mode. Note :Relay state default off The device support below metering scale.
-0x00 Accumulate power consumption (kWh)
-0x02 Power consumption (W)
-0x04 AC load voltage (V)
-0x05 AC load current (A)
-0x06 Load power factor (PF)
(In the meanwhile, our device will send its
2
SW-ESW01N QIG V0.5
Loading...