Sercel VIB 0006B User Manual

Unite CANII User Manual
VIB-E-US-389B-1.2
19 September 2008
This document may not in whole or part be copied, reproduced, or reduced to any medium without prior consent, in writing, from Vibration Technology Ltd.
Disclaimer:
Every effort has been made to ensure the accuracy of the material provided herein; however Vibtech assumes no responsibility regarding the use of the material. Additionally, Vibration Technology Ltd. shall not be liable for any misuse of this product.
Contact Information:
Vibration Technology Limited, A Sercel Company
Vibtech House 5 Central Boulevard, Central Park Larbert, FK5 4RU SCOTLAND, UK Tel: +44 (0)1324 556 777 Fax: +44 (0)1324 556 222
Email: support@vibtech.co.uk
Website: http://www.vibtech.co.uk
VIB-E-US-389B-1.2; 19/09/2008 2 of 10
1 INTRODUCTION ........................................................................................................................................ 4
1.1 Related Documents ................................................................................................................................ 4
2 ELECTRICAL INTERFACE AND CONNECTORS .................................................................................... 4
2.1 Power Connector .................................................................................................................................... 4
2.2 Ethernet Connector................................................................................................................................. 4
2.3 RF Connector.......................................................................................................................................... 4
3 ANTENNA INSTALLATION........................................................................................................................ 5
3.1 CANII Hardware...................................................................................................................................... 5
3.2 CAN Network Schematic ........................................................................................................................ 5
3.3 CAN Field Deployment ........................................................................................................................... 6
3.3.1 CAN Placement ............................................................................................................................... 6
3.3.2 CAN Mast Assembly........................................................................................................................ 7
3.3.3 CAN RF Coverage........................................................................................................................... 8
3.3.4 Network Connection ........................................................................................................................ 8
4 LED INDICATORS ..................................................................................................................................... 9
5 AP INFORMATION..................................................................................................................................... 9
6 REGULATORY INFORMATION ................................................................................................................ 9
6.1 FCC Compliance..................................................................................................................................... 9
6.1.1 FCC Statement ................................................................................................................................ 9
6.1.2 Caution ............................................................................................................................................ 9
6.1.3 RF exposure statement ................................................................................................................... 9
7 GUIDELINES FOR SAFE AND EFFICIENT USE.................................................................................... 10
7.1 General ................................................................................................................................................. 10
7.2 Product Care......................................................................................................................................... 10
7.3 Personal Care ....................................................................................................................................... 10
VIB-E-US-389B-1.2; 19/09/2008 3 of 10
1 Introduction
This User Manual contains some important information about the Vibration Technology Ltd seismic cell acquisition node (CAN) Unit. It is important that you read the information contained herein before putting your Unit into operation.
1.1 Related Documents
VIB-E-US-388 Unite System Installation & Network Deployment Manual VIB-E-US-390 Unite System Maintenance Manual VIB-E-PC-146 Unite System Software Update Procedure VIB-E-US-389 Unite System User Manual
2 Electrical Interface and Connectors
2.1 Power Connector
The CANII unit has two 8-way power connectors on the right side of the enclosure wired in parallel to allow for battery hot swapping. The pinout is as follows:
Pin Signal
A +12V B GND
2.2 Ethernet Connector
The CANII unit has four 8-way Ethernet connectors on the front panel of the enclosure to allow for up to 4-off Ethernet connection. The pinout is as follows:
Pin Signal
B GND D +12V E TX+ F TX­G RX+ H RX-
2.3 RF Connector
The CANII unit has three N-type female RF connectors on the left side panel of the enclosure to allow for connection of the 3-sector antenna array. The connector can also be driven with a 5.1V power level on the inner core for future power over coax applications. The pinout is as follows:
Pin Signal
Centre Signal (+5.1V)
Outer GND
VIB-E-US-389B-1.2; 19/09/2008 4 of 10
3 Antenna Installation
14dBi gain
2.6dBi loss
Power budget:
The antenna (and support equipment) is supplied and installed by Vibtech personnel.
3.1 CANII Hardware
The CANII (deployment) hardware is comprised of the following components:
Vibtech CANII (VIB-999-0006B) Vibtech p/n CANII unit VIB-999-0006B CANII battery VIB-400-0005 WLAN base station 2.4GHz sectored antenna, 14dBi, 16deg, N-male VIB-800-0006 LMR400 Ultraflex cable, N-type (male-female), 50Ohm, 10m (3-off) (2.6dB loss) VIB-350-0026BU Shelley Clamp (upto 50mm tubing) VIB-850-0016 Mobile Mast 28' (8.5m) steel inc carry bag and step VIB-850-0056C
3.2 CAN Network Schematic
Point to Multipoint
AP output 18dBm Connector loss 2dBm Cable loss 2.6dBm Antenna gain 14dBi TX eirp 27.4dBm
Battery
CANII
ANTENNA
Antenna N-male to cable N-female
LMR400UF
CAN N-female to cable N-male
VIB-E-US-389B-1.2; 19/09/2008 5 of 10
3.3 CAN Field Deployment
AP0
AP1 AP2
3.3.1 CAN Placement
The CAN should be deployed with the red sector pointing north.
To blue (black) marked panel/cable on antenna
To green marked panel/cable on antenna
To red marked panel/cable on antenna
VIB-E-US-389B-1.2; 19/09/2008 6 of 10
3.3.2 CAN Mast Assembly
Safety First
“The mast deployment is a two-man job. Each member of personnel must have steel capped boots, hard hat, goggles and safety gloves during the mast deployment.”
The CAN mast should be installed as follows:
Position mast at desired location
Attach Antenna (p/n: VIB-800-0006) to mast (p/n: VIB-850-0056C) top section through mast tripod
base section using clamp (p/n: VIB-850-0016)
Connect RF cables (p/n: VIB-350-0026BU) to each of the antenna sectors (3-off) and tape off.
Attach safety guys lines to clamp and stake in ground pegs 5m from mast base at 120degree
separation
Push antenna upwards (through tripod base) inserting a new pole section piece at a time until the desired height has been obtained
Attach the guys lines to the pegs and tighten, All three guy lines should be tight with the antenna and mast vertically straight
VIB-E-US-389B-1.2; 19/09/2008 7 of 10
3.3.3 CAN RF Coverage
AP0
AP1 AP2
Issue Examination / Action Antenna, Height & Tilt
Ensure that the CAN antenna cables are damage free and that all three cables are correctly and securely connected. All damaged or faulty components should be replaced.
Check the sequence of the RF cable assembly connections, the RED,
GREEN, BLUE (black) sequence must be observed as per below.
The CAN panel antenna has an azimuth beamwidth (radiation pattern or signal path) of 120° and an elevation beamwidth of 16°. These radiation patterns must be observed in order to assess RAU-CAN coverage.
16°
15° mechanical uptilt
120°
16°
15° mechanical downtilt
16°
The CAN sectorised antenna can be mechanically adjusted up to 15° of uptilt or downtilt per sector. This allows the flexibility to adjust the antenna radiation pattern to the surrounding terrain thereby maximising the pattern performance for optimal RAU coverage.
On flat terrain a 0°, 1° or 2° of downtilt will be best. On slopes, gorges and hilly areas the mechanical tilt must be adjusted to alter the elevation beam width in order to maximise RAU coverage.
The height of the CAN antenna should be at least 5m, higher if possible, unless forest canopy would restrict RF propagation.
3.3.4 Network Connection
Power up the CAN using the battery cable assembly pigtail (p/n: VIB-400-0005). There are LEDs on the outside of the CAN to show power up status and connectivity/activity on all the external port connectors.
Check the CAN has powered up by viewing the LEDs next to battery port# 1.
CANII with battery connected
The main CAN power LED should be lit and indicate red.
VIB-E-US-389B-1.2; 19/09/2008 8 of 10
If the CAN has failed to power up, check the battery connection and voltage level, replace the battery if required. If the battery is okay (>12V) swap out the CAN. The CAN should be examined as per maintenance procedure (VIB-E-US-389, Unite System Manual).
When successfully connected, the first CAN should appear on the NIPGUI CAN list.
4 LED Indicators
The CANII incorporates an array of LEDs to indicate status as defined in the following table:-
LED Colour Status
Side panel bottom Red On – power good
Off – no power
Side panel top Green On (flashing) – power up test
On (constant) – Status good
Off – status bad Ethernet Port front panel connectors
The status LED is placed in an off state during sleep mode.
Green On - LAN Port connection LINK OK,
Off - no or bad connection
Table 1 : LED Indicators
5 AP Information
The table below contains the AP properties
Parameter Data RF output power (max) 18dBm (software selectable) Receiver sensitivity (802.11b) -95dBm (1Mbps), -90dBm (11Mbps) Operating frequency 2.402 – 2.480 GHz, ISM band Power 12V
6 Regulatory Information
6.1 FCC Compliance
6.1.1 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
6.1.2 Caution
No modification to the radio or antenna is permitted, and any modification could cause the device to cease to comply with FCC rules part 15, and thus void the user’s authority to operate the equipment.
6.1.3 RF exposure statement
This modular transmitter MUST have a separation distance of at least 20cm between the antenna and the body of the user or nearby persons, excluding hands, wrists, feet, and ankles.
VIB-E-US-389B-1.2; 19/09/2008 9 of 10
7 Guidelines for Safe and Efficient Use
7.1 General
Read this information before using your CANII. For any exceptions, due to national requirements or limitations, when using your CANII, please contact Vibration Technology Ltd.
Note: Changes or modifications to the product not expressly approved in writing by Vibration Technology Ltd will void the user’s authority to operate the equipment.
7.2 Product Care
Do not open or disassemble your CANII. Doing so will void any warranty. The CANII does not contain any user serviceable or replaceable components. Service may only be performed by Vibration Technology Ltd or an authorised service agent.
Do not expose your CANII housing to solvents or any substance containing solvents such as paints or lacquers.
Do not expose your CANII to hot or cold temperatures outside of those specified in the data sheet.
Do not expose your CANII lit candles, cigarettes, cigars, naked flames etc.
Do not drop or throw your CANII as it could sustain damage
If your CANII is to be stored, store it in a place that is dry and protected from extreme heat or cold.
7.3 Personal Care
The CANII contains radio transmitter and receiver devices. During communication with Unite Infrastructure or Data Harvesters, the Unit receives and transmits radio frequency (RF) electromagnetic fields (microwaves) in the frequency range 2400 to 2500 MHz. The output power of the radio transmitter is very low.
If you are in proximity to a CANII whilst it is powered on, you will be exposed to some of the transmitted RF energy. This exposure is well below the prescribed limits in all national and international RF safety standards and regulations.
VIB-E-US-389B-1.2; 19/09/2008 10 of 10
Loading...