Serbal PHW, FGW Instructions For Use Manual

Instructions for use
HD/SDI-TO-FIBRE
CONVERTER
2
www.lemo.com
12V DC In
PHW.MT.3KC.TPVP10 / S
00010 / Preserie / 1007
HD/SDI-TO-FIBRE CONVERTER
A
SERBAL Model: PHW
TM
(A)
B
SERBAL Model: FGW
BACK PANEL SERBAL SERBAL Model: PHW and FGW
TM
(B)
TM
(A)
TM
(B)
12
3
12V DC In
00010 / Preserie / 1007
PHW.MT.3KC.TPVP10 / S
12
HD / SDI
5
Out 1 Out 2 Out 3 Out 4
4
3
www.lemo.com
1 Power socket
2 HDTV connector
(ARIB, SMPTE, EBU compatible)
3 Part number and model
4 BNC connector
5 LED indicators
Getting to know the SERBAL
TM
Before operating the system please read the User Manual.
Warning
To prevent fire or shock hazard, do not immerse the unit in water.
To avoid electrical shock, do not re­move covers or panels.
To prevent overheating risk, ventilate the units correctly.
Only use the power supply included.
Refer servicing to qualified personnel only.
The SERBALTMprovides a compact con­version unit which allows transmission of HD/SDi video from up to 4 cameras to be transmitted over a single standard LEMO 3K.93C SMPTE cable.
How does it work?
The SERBALTMutilises Wavelength Di­vision Multiplexing (WDM). Each fibre carries two optical signals at different wave lengths. By converting the elec­trical signals into fibre optic signals clearer error free transmission can be obtained over greater distances.
3 different systems to suit your requirements
The system is available in three versions:
- 4 x HD/SDI signals from the cameras to the OB van
- 2 x HD/SDI signals from the cameras to the OB van, 2 signals for monitor feedback
- 3 x HD/SDI signals from the cameras to the OB van, 1 signal for monitor feedback
4 channel coaxial to fibre media converter
4
www.lemo.com
The SERBALS works as a system pair. Place the first SERBALTMat the camera side (identified as part number PHW) and the second SERBALTMat the CCU / OB van side (identified as part number FGW)
HDTV connectors.
Connect the HDTV connector (LEMO 3K.93C Series) to the appropriate HDTV compatible socket or plug. Note: as with HDTV systems ensure that the HDTV (SMPTE) cable is laid in the appropriate direction - socket at the OB van / CCU end and plug at camera end.
BNC connectors.
Connect up to 4 cable leads with BNC connectors from the SERBALTMto the camera or feedback monitor. The connection done on the OB van/ CCU side is similar.
SERBAL Power Supply.
Connect the unit to a suitable power source by using the AC/DC adaptor (12 Volts) supplied.
Operating Instructions
HD/SDI HD/SDI
SERBAL™
CCU SIDECAMERA SIDE
FIBRE
SERBAL™
Local 12V source
COAX COAX
(1.5 A max)
Camera 1
Camera 2
Camera 3
Camera 4
4 x Tx signal
Coaxial HD/SDI Coaxial HD/SDI
SERBAL™
Local 12V source (1.5 A max)
SMPTE cable
Fibre optic
SERBAL™
OB van
4 x Rx signal
Camera 1
Camera 2
Feedback monitor 1
Feedback monitor 2
Camera 1
Camera 2
Camera 3
Feedback monitor 1
2 x Tx signal
2 x Rx signal
2 x Tx signal
1 x Tx signal
1 x Rx signal
Coaxial HD/SDI Coaxial HD/SDI
SERBAL™
Coaxial HD/SDI Coaxial HD/SDI
SERBAL™
SMPTE cable
Fibre optic
SMPTE cable
Fibre optic
SERBAL™
SERBAL™
OB van
2 x Rx signal
2 x Tx signal
OB van
2 x Rx signal
1 x Rx signal
1 x Tx signal
5
www.lemo.com
BNC connector (75 Ohms)
LEMO connector 3K.93C Series, (HDTV)
SMPTE 292M, SMPTE 259M, SMPTE 297M SMPTE 305M, SMPTE 310M,DVB-ASI
LEMO 0K Series, 2pin in-line transformer
I/O ports
Signal Standards
DC in
Input/outputs Connectors
1310nm /1550 nm
- 6 dB @ 1310 nm
- 4.5 dB @ 1550 nm
- 30 dB @ 1310 nm
- 30 dB @ 1550 nm
up to 300 m @ 270 Mb/s
up to 100 m @ 1.485 Gb/s
> 15 dB @ 1.485 Gb/s
Transm. wavelength
Optical launch power
Optical receive sensitivity
Equalisation (camera side)
Return loss
Signals Values
1
with UK, USA, Europe adaptors
1
AC/DC power supply
User's guide
Supplied accessories Quantity
89/336/EEC
EN 61000-6-1 EN 61000-6-2
EMI/RFI
Electrical
Conformance Standard
172 W x 125 L x 50H mm
2Kg
100 to 120 Vac, 50/60Hz
220 to 240 Vac, 50/60 Hz
12 Vdc / 1.5A max
-30°C to + 70°C
up to +95 %
IP50
Dimensions
Mass (approx.)
Power requirements In North America, Japan and areas of South America
Power requirements In Europe, Africa, Australia, Scandinavia, China
Operating voltage
Operating temperature
Humidity
Index protection
General Values
2SM-9.2-37.5
TV-OM-AMS
TV-OM-HAMS
B-97J501
CT2987300
7804C
M96040
M95421
Furukawa
Furukawa
Furukawa
Fujikura
Draka
Belden
Mohawk
Mohawk
Manufacturer Part Number (camera cable)
Specifications Recommended variants
of SMPTE-311M Cable
Part Number
The SERBALTMsystem always works as a pair. These are identified as PHW (camera side) and FGW (CCU side) in the operating instructions.
The part number of your purchased product is located on the top of the unit (see above).
F
G
W
.
M
S
.
3
C
2
.
T
P
B
C
M
FGW.MS.3C2. TPBCM
0
0007 / 9319453 / 5
0
07
000
07 / 931 9453 / 5007
12V DC in12
V DC in
Camera side
CCU side
SERBAL™
Part number
PHW.MS.3C4.TPBCC
PHW.MS.3C2.TPBCC
PHW.MS.3C3.TPBCC
FGW.MS.3C4.TPBCM
FGW.MS.3C2.TPBCM
FGW.MS.3C3.TPBCM
Broadcast
setup
4 Tx signals (return video)
2 Tx signals + 2 Rx signals
3 Tx signals + 1 Rx signal
4 Rx signals (video feed)
2 Rx signals + 2 Tx signals
3 Rx signals + 1 Tx signal
6
www.lemo.com
Troubleshooting
Why doesn’t it work the way I want?
This section lists some problems you might en ­counter during the use of the SERBALTM. Some problems require that you call your local support, but other problems can easily be solved.
The device doesn’t operate.
Are the LED's lit (see diagram page 2)? If not, check that the power supply is correctly plugged in. If one of the LED’s is not functioning, check that the associated cable is correctly plugged in.
No Power
Power. No Signal
Power and Signal present
Off
Red
Green
LED status Description
CAUTION Class 1 Laser Product
The SERBALTMis classified as a CLASS 1 LASER PRODUCT. Do not stare into the beam or view it directly with optical instruments.
Recommendations
Do not paint your product. Always treat your product with care and keep the fibre optic connectors capped when not in use.
Cleaning Instructions
It is essential that the optical interface (ferrule end faces) of the 3K.93C fibre optic contacts are clean and free from any kind of debris to ensure the correct performance and operation of the contact. It is recommended that the inspection and cleaning instructions provided by LEMO are used on the 3K.93C connector to ensure the connector performs to the specified ratings.
The device gets warm.
This is normal; the units get warm during normal operation. The shell heat exchanger should be kept free of obstructing materials and not covered, in order to dissipate the heat.
Certifications and warranty
CE marking
CE marking means that the appliance or equipment bearing it complies with the protection requirements of one or several European safety directives.
RoHS statement
LEMO products are in compliance with the RoHS directives (2002/95/EC) of the European Parliament. This directive specifies the restrictions of the use of hazardous substances in electrical and electronic equipment marketed in Europe.
LEMO guarantees that its connectors and media converters are free of mercury, cadmium, lead, hexavalent chromium and polybromide biphenyl (PBB) or polybromide diphenyl ether (PBDE).
Technical support
We understand you may have ques tions regarding your new product. Should you require any assistance, our technical support and customer service is available to you. Whenever calling your LEMO support, you will need to refer to the part numbers located on the top the SERBALTMunit.
Europe email: mc_europe@lemo.com
Europe telephone:
0044 (0) 1903 222411
USA email:
mc_usa@lemo.com
USA telephone:
(+1 707) 578 88 11
Asia/Pacific email: mc_asia@lemo.com
Japan telephone:
+81-3-5446-5510
China telephone:
(86 21) 5899 7721
Warranty - 5 years
LEMO warrants this product to be free from defects in design, material and workmanship under normal use for the period of five (5) years from purchase date.
If during the warranty period, this product should fail under normal operation, LEMO will, at its option, replace or repair the defective part.
This warranty does not include failure caused by improper installation, ope ration, accident, improper connec tion to peripherals, software or hardware modifications outside of LEMO’s control.
www.lemo.com
Design and specifications are subject to change without notice.
7
LEMO HEADQUARTERS
SWITZERLAND LEMO SA
Chemin des Champs-Courbes 28 P.O. Box 194 - CH-1024 Ecublens Tel. (+41 21) 695 16 00 - Fax (+41 21) 695 16 02 e-mail: info@lemo.com
LEMO
AUSTRIA LEMO Elektronik GesmbH
Tel: (+43 1) 914 23 20 0
CANADA LEMO CANADA Inc
Tel: (+1 905) 477 77 22
CHINA LEMO Trading (Shanghai) Co., Ltd.
Tel: (+86 21) 5899 7721
DENMARK LEMO Denmark A/S
Tel: (+45) 45 20 44 00
FRANCE LEMO France Sàrl
Tel: (+33 1) 60 94 60 94
GERMANY LEMO Elektronik GmbH
Tel: (+49 89) 42 77 03
HONG KONG LEMO Hong Kong Ltd.
Tel: (+852) 21 74 04 68
HUNGARY REDEL Elektronika Kft
Tel: (+36 1) 421 47 10
ITALY LEMO Italia srl
Tel: (+39 02) 66 71 10 46
SUBSIDIAIRIES
JAPAN LEMO Japan Ltd
Tel: (+81 3) 54 46 55 10
NETHERLANDS / BELGIUM LEMO Connectors Nederland B.V.
Tel: (+31) 251 25 78 20
NORWAY / ICELAND LEMO Norway A/S
Tel: (+47) 22 91 70 40
SINGAPORE LEMO Asia Pte Ltd
Tel: (+65) 6476 0672
SPAIN / PORTUGAL IBERLEMO S.A.
Tel: (+34 93) 860 44 20
SWEDEN / FINLAND LEMO Nordic AB
Tel: (+46 8) 635 60 60
SWITZERLAND LEMO Verkauf AG
Tel: (+41 41) 790 49 40
UNITED KINGDOM LEMO UK Ltd
Tel: (+44 1903) 23 45 43
USA LEMO USA Inc
Tel: (+1 707) 578 88 11
© DOC.MS.W3C0.000 - Printed in Switzerland, November 2012
LEMO DISTRIBUTORS
AUSTRALIA, BRAZIL, CZECH REPUBLIC, GREECE, INDIA, ISRAEL, NEW ZEALAND, PAKISTAN, POLAND, RUSSIA, SOUTH AFRICA, SOUTH KOREA, TAIWAN, TURKEY, UKRAINE
www.lemo.com
www.lemo.com
Loading...