SEON SA-MIC Remote Microphone, SA-MIC Setup Manual

Service and Warranty
If your product is to be returned to Seon Design for service, please call toll free 877-630-7366, or 604-524-6437 and ask for a Return Authorization (RA) number. An RA number allows the Service Technicians to better track your product when it comes in for service. Please show the RA number on the outside of the package. ANY PRODUCT SENT TO SEON DESIGN WITHOUT AN RA NUMBER MAY BE REFUSED.
Please refer to the Warranty form provided with your product to review the terms of warranty service, contact and shipping information, as well as other important issues regarding the service and operation of your product.
© 2003 Seon Design Inc. All rights reserved. Document Part Number: 700-0010-01
Features
The SA-MIC is a high quality, impact resistant remote microphone that installs easily into a variety of locations. With the use of the base adapter gasket, the SA-MIC can be installed with the cable concealed or surface-run.
SA-MIC Remote Microphone
Installation
1 The first step in installing the SA-MIC is to decide if the cable
2 Figure 2 below shows the assembly of the SA-MIC. Use the
mounting template shown in Figure 3 to drill pilot holes for the #10 mounting screws included in the hardware kit. Also, if the cable is to be concealed, drill a hole in the mounting surface for the cable connectors to pass through.
3 For easier installation, the cable can be removed from the
microphone by using a small slot screwdriver to undo the connections from the terminal blocks. Refer to Figure 4 for the wiring connections to the terminal blocks on the SA-MIC circuit board.
4 Mount the SA-MIC base using the two #10 rubber washers and
two #10 x 3/4" sheet metal screws provided. Make sure the gasket is properly aligned.
5 Install the SA-MIC cover using the two #6-32 x 1/4" machine
screws provided. Install one side first, but do not tighten the screw. Install the screw in the second side, and then tighten both screws.
Cut Gasket Here To
Figure 1: Base Adapter Gasket
Surface-Run Cable
#10 Sheet Metal Screws and Washers
Figure 2: SA-MIC Installation
Cable Hole
Mounting Holes
Figure 3: Mounting Template
Sensitivity Adjustment
White Wire: Audio Ground
Green Wire: Audio +
Black Wire: Ground
Figure 4: Terminal Block Wiring
Red Wire: +12VDC
Operation
The SA-MIC powers from 12VDC and provides a line-level audio signal for direct interfacing with many devices, including video cassette recorders, digital video recorders, monitors, etc. The only adjustment on the SA-MIC is the sensitivity. The default sensitivity is set in the middle of the control. Turning the control clockwise will increase the sensitivity. Some environments can be very noisy; set the sensitivity to a safe level that will not overload the receiving device under normal operating conditions.
Specifications
Frequency response: 200 Hz – 5 kHz Sensitivity: -45 dB Audio Output: Line level Minimum Load: 600 ohm Operating Voltage Range: 8 VDC – 18 VDC Operating Temperature Range: 14°F to 140°F
-10°C to 60°C Enclosure Size: 2.75” (70 mm) diameter
0.75” (19 mm) height Gasket Size: 2.875” (73 mm) diameter
0.25” (6.5 mm) thick Cable Length: 30 ft (9.1 m) Audio Connector: RCA, red Power Connector: 2.1 mm barrel
- center positive Weight: 4.5 oz (125 g)
- without cable
13.5 oz (375 g)
- with cable
Loading...