Sentry US NC-DS2, NC-DS2-ST, NC-DS2-KP, NC-MON4, NC-DS2-SLIM Operation & Installation Manual

...
Page 1
24
www.SentryUS.com
www.ZRFID.com
Additional Technology Security Inc.
dba: Sentry US
5500 Stewart Avenue
E-mail: info@SentryUS.com
Tel: 1-800-916-8783
International: 510-279-9992
ZRFID is an affiliate of Sentry US
Specialized in Access Control Products
Copyright © 2010~2012. R201205-V02
Copyright © 2010~2012. All rights reserved. www.SentryUS.com R201205-V02
Operation&InstallationManual
Color IR Camera & Video
Intercom System - 24 Series
Color IR Camera Outdoor Stations: Max.
Standard Slim Type With Keypad
NC-DS2
5.91”(W)x9.06”(H)x1.69”(D)
Recessed
NC-DS2-ST
3.54”(Wx5.12”(H)x1.69”(D)
Surface
NC-DS2-SLIM
2.17”(W)x5.12”(H)x1.54”(D)
Surface
NC-DS2-KP
2.95”(W)x7.48”(H)x1.77”(D)
Surface
Color Monitor Inside Stations:
Main Monitor
Sub Monitor
Audio Phone Set
NC-MON4
9.45”(W) x 6.89”(H) x 1.5”(D)
Surface
NC-MON4-SUB
9.45”(W) x 6.89”(H) x 1.5”(D)
Surface
NC-APS
3.0”(W) x 9.06”(H) x 2.31”(D)
Surface
RoHS
Page 2
2
Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with sep arate collection systems).
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
CAUTION
1. Handle this product with care
Avoid any shock or bumping of the product. Improper handling could damage the
product.
2. Requires a proper operating environment The main and sub monitors are designed for indoor use. The allowable temperature
range for operation of this product is between 14°F ~ 131°F / -10°C ~ 55°C. The camera outdoor stations are designed for outdoor use. The allowable temperature range for operation of this product is between -4°F ~ 131°F / -20°C ~ 55°C.
3. Check the power source voltage The power source voltage should be within the specified range. (Product must meet
the specifications).
4. Objects and liquid entry Never push objects of any kind into this product as this may touch dangerous voltage
points of short out parts that could result in a fire or electric shock. Never spill any kind of liquid on the indoor products.
5. Servicing
Do not attempt to service this product by yourself as opening or removing covers
may expose you to dangerous voltage or other hazards. Refer all service to qualified servicing personnel.
Please read the Manual before attempting to use this product.
4
24 SERIES FEATURES
Color IR Camera Outdoor Stations:
NC-DS2
1/3” CCD; 420 TVL; 0.05 Lux
120 sec Communication Duration
Duplex Communication Type
Recessed Mounting
IP55 Rating; 12V~14.5V DC, 200mA
5.91” x 9.06” x 1.69” 175mm x 230mm x 43mm
NC-DS2-ST
1/3” CCD; 420 TVL; 0.05 Lux
3.6mm Lens
Hands-free Talking
120 sec Communication Duration
Duplex Communication Type
Surface Mounting
IP55 Rating; 12V~14.5V DC, 100mA
3.54” x 5.12” x 1.69” 90mm x 130mm x 43mm
NC-DS2-SLIM
1/3” CCD; 420 TVL; 0.05 Lux
3.6mm Lens
Hands-free Talking
120 sec Communication Duration
Duplex Communication Type
Surface Mounting
IP55 Rating; 12V~14.5V DC, 100mA
2.17” x 5.12” x 1.54” 55mm x 130mm x 39mm
NC-DS2-KP (code only)
1/3” CCD; 420 TVL; 0.05 Lux
3.6mm Lens
Hands-free Talking
120 sec Communication Duration
Duplex Communication Type
Personal Password Door Release
Surface Mounting
IP55 Rating; 12V~14.5V DC, 100mA
2.95” x 7.48” x 1.77” 75mm x 190mm x 45mm
Color Monitor Inside Stations:
NC-MON4 - Main
7” Screen
2 min. Talking Time
Dual Transmission Mode
Surface Mounting
12V~14.5V DC, 800mA, 50/60Hz
Stand by 50mA
9.45” x 6.89” x 1.5”
240mm x 175mm x 38mm
NC-MON4-SUB
7” Screen
2 min. Talking Time
Dual Transmission Mode
Surface Mounting
12V~14.5V DC, 700mA, 50/60Hz
Stand by 70mA
9.45” x 6.89” x 1.5” 240mm x 175mm x 38mm
Inside Audio Station:
NC-APS
Surface Mounting
12V~14.5V DC
3.0” x 9.06” x 2.31” 76mm x 230mm x 58mm
Page 3
22
Access Control Readers
Proximity ID Reader Mifare IC Reader ACR-EM26SA ACR-MF26SA
125 kHz, 9V~15V DC 13.56 MHz, 9V~15V DC Wiegand 26, IP-65 Wiegand 26, IP-65 Current: 35mA/avg, 100mA/peak Current: 35mA/avg, 100mA/peak
Proximity ID Reader Mifare IC Reader ACR-EM26STA ACR-MF26STA
125 kHz, 9V~15V DC 13.56 MHz, 9V~15V DC Wiegand 26, IP-65 Wiegand 26, IP-65 Current: 35mA/avg, 100mA/peak Current: 35mA/avg, 100mA/peak
Proximity ID Reader Mifare IC Reader ACR-EM26STB ACR-MF26STB
125 kHz, 9V~15V DC 13.56 MHz, 9V~15V DC Wiegand 26, IP-65 Wiegand 26, IP-65 Current: 35mA/avg, 100mA/peak Current: 35mA/avg, 100mA/peak
Proximity ID Reader Mifare IC Reader ACR-EM26STC ACR-MF26STC
125 kHz, 9V~15V DC 13.56 MHz, 9V~15V DC Wiegand 26, IP-65 Wiegand 26, IP-65 Current: 35mA/avg, 100mA/peak Current: 35mA/avg, 100mA/peak
3
INDEX
FEATURES ………………………………………………………………………………….... 4
PACKAGE CONTENTS ………………………………………………………………….… 5-6
APPLICATION DIAGRAM ………………………………………………..….……….…...… 7
PARTS & FUNCTIONS – COLOR IR CAMERA OUTDOOR STATION ………………. 7-9
PARTS & FUNCTIONS – COLOR MONITOR INSIDE STATION ………………...… 10-11
PARTS & FUNCTIONS – AUDIO PHONE SET ………………………………..………… 11
WIRING CONNECTION SYSTEM DIAGRAM ……...…………………………………..… 12
INSTALLATION ….………………………………………..…….………………..……… 1-14
OPERATION …………………………………………………………………..………… 15-17
CODE ACCESS FOR NC-DS2-KP ……………………………………………….…… 18-19
SPECIFICATIONS ……………………………………………………………………..… 19-20
LIMITED WARRANTY ………………………………………………………………….…… 20
OPTIONS ………………………………………………………………………………..…… 21
RELATED PRODUCTS ………………………………………………………………… 21-23
Page 4
4
24 SERIES FEATURES
Color IR Camera Outdoor Stations:
NC-DS2
1/3” CCD; 420 TVL; 0.05 Lux
120 sec Communication Duration
Duplex Communication Type
Recessed Mounting
IP55 Rating; 12V~14.5V DC, 200mA
5.91” x 9.06” x 1.69” 175mm x 230mm x 43mm
NC-DS2-ST
1/3” CCD; 420 TVL; 0.05 Lux
3.6mm Lens
Hands-free Talking
120 sec Communication Duration
Duplex Communication Type
Surface Mounting
IP55 Rating; 12V~14.5V DC, 100mA
3.54” x 5.12” x 1.69” 90mm x 130mm x 43mm
NC-DS2-SLIM
1/3” CCD; 420 TVL; 0.05 Lux
3.6mm Lens
Hands-free Talking
120 sec Communication Duration
Duplex Communication Type
Surface Mounting
IP55 Rating; 12V~14.5V DC, 100mA
2.17” x 5.12” x 1.54” 55mm x 130mm x 39mm
NC-DS2-KP (code only)
1/3” CCD; 420 TVL; 0.05 Lux
3.6mm Lens
Hands-free Talking
120 sec Communication Duration
Duplex Communication Type
Personal Password Door Release
Surface Mounting
IP55 Rating; 12V~14.5V DC, 100mA
2.95” x 7.48” x 1.77” 75mm x 190mm x 45mm
Color Monitor Inside Stations:
NC-MON4 - Main
7” Screen
2 min. Talking Time
Dual Transmission Mode
Surface Mounting
12V~14.5V DC, 800mA, 50/60Hz
Stand by 50mA
9.45” x 6.89” x 1.5”
240mm x 175mm x 38mm
NC-MON4-SUB
7” Screen
2 min. Talking Time
Dual Transmission Mode
Surface Mounting
12V~14.5V DC, 700mA, 50/60Hz
Stand by 70mA
9.45” x 6.89” x 1.5” 240mm x 175mm x 38mm
Inside Audio Station:
NC-APS
Surface Mounting
12V~14.5V DC
3.0” x 9.06” x 2.31” 76mm x 230mm x 58mm
21
OPTIONS
A. Electric Door Strikes for Metal Door
B. Electric Door Strikes for Wood Door
C. Buzzer
RELATED PRODUCTS from www.ZRFID.com Stand-Alone Access Control Keypads
Stand-Alone Access Control Keypads w/ Built-in EM/125KHz Reader ACSK-EM
Outdoor IP-65 12V~15V DC
Stand-Alone Access Control Slim Type Keypad w/ Built-in EM/125KHz Reader ACS45K-EM
Outdoor IP-65 12V~15V DC
Buzzer Connection:
1. Connect the buzzer positive (+) to lock strike positive (+)
2. Connect the buzzer negative (-) to power negative (-)
5~14V DC
Jaw Strength: 2000 lbs
12V DC
Jaw Strength: 2000 lbs
12V DC
Page 5
20
7” COLOR MONITOR INSIDE STATION
Model NC-MON4 NC-MON4-SUB Type
Main Monitor Sub Monitor
Screen Size
7”
Voltage
12V ~14.5V DC, 50/60Hz
Stand by
50mA
Mode
Dual Transmission
Working Current
800mA
Talk Time
2 min
Working Temperature
14°F ~ 131°F / -10°C ~ 55°C
Mounting Type
Surface
Dimension
9.45” x 6.89” x 1.5” / 240mm x 175mm x 38mm
*Specifications are subject to change without notice
AUDIO PHONE SET
Model NC-APS Voltage
12V~14.5V DC
Stand by
70mA
Working Current
100mA
Mounting Type
Surface
Dimension
3.0” x 9.06” x 2.31” / 76 x 230 x 58 mm
*Specifications are subject to change without notice
LIMITED WARRANTY
LIMITED ONE (1) YEAR WARRANTY AND EXCLUSIONS
Manufacturer warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Manufacturer is free of defects in materials and workmanship under normal and proper use for one (1) year from the purchase date. Manufacturer's only obligation is to correct such defects by repair or replacement, at its option, if within such one (1) year period the product is returned prepaid, with proof of purchase date, and a description of the problem. This warrant excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper
environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other implied warranties of any kind, including merchantability and fitness or a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the
duration of any such implied warrant, including merchantability and fitness of or a particular purpose, is limited to one (1) year. Manufacturer is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to, or loss of use of, any equipment, loss sales or profits or delay or failure to perform this warranty obligation. The
remedies, provided therein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
5
PACKAGE CONTENTS
NC-DS2
NC-DS2-ST
NC-DS2-SLIM
NC-DS2-KP
One (1) NC-DS2
o One (1) Flush Mounting Back
Cover
o Four (4) Long Mounting Screws o One (1) Allen Wrench o One (1) Manual
One (1) NC-DS2 -ST
o Three (3) Short Mounting Screws o Three (3) Wall Anchors o One (1) Allen Wrench o One (1) Manual
One (1) NC-DS2 -SLIM
o Two (2) Short Mounting Screws o Two (2) Wall Anchors o One (1) Manual
One (1) NC-DS2 -KP
o Three (3) Short Mounting Screws o Three (3) Wall Anchors o One (1) Allen Wrench o One (1) Manual
Page 6
6
NC-MON4
NC-MON4-SUB
NC-APS
For any returns, please include all components listed above with original packaging in
Resalable Condition
. Absolutely No Returns will be accepted if any component is
missing/damaged.
IMPORTANT NOTE!
The Main monitor (NC-MON4) and Sub monitor (NC-MON4-SUB) must be used
with Sentry US’s 14.5V DC power supply (AC-POWERDC) and each monitor
requires its own power supply.
One (1) NC-MON4
o One (1) Metal Mounting Bracket o Two (2) Short Mounting Screws o Two (2) Wall Anchors o One (1) Power Connector Cable o Two (2) 4-wire Connector Cables o One (1) Manual
One (1) NC-MON4-SUB
o One (1) Metal Mounting Bracket o Two (2) Short Mounting Screws o Two (2) Wall Anchors o One (1) Power Connector Cable o Two (2) 4-wire Connector Cables o One (1) Manual
One (1) NC-APS
o One (1) Mounting Plate o Two (2) Short Mounting Screws o Two (2) Wall Anchors o One (1) 4-wire Connector Cables o One (1) Manual
19
Delete All Settings
1. Enter programming mode.
2. Press the # button and the unit will beep two “Di Di” sounds as a reminder.
3. Press the # button again and two additional beeps will sound.
4. Continuously press the # button seven times to delete all settings. Unlocking time turns to one second. The Admin Codes are same as before. After 5 seconds, all settings will set back to default.
5. Press the
button to quit.
* NC-DS2-KP works with code only. No EM Card.
SPECIFICATIONS
COLOR IR CAMERA OUTDOOR STATION
Model NC-DS2 NC-DS2-ST NC-DS2-SLIM NC-DS2-KP Unit Type Standard Standard Slim With Keypad Power
12V ~ 14.5V DC
Electric Current
Working 200mA
Image
1/3” CCD; 420 TV Lines
Camera Lens
72° ken; 3.6mm Lens
Illumination
0.05 Lux
Communicatio n Duration
120 sec
Communicatio n Method
Duplex communication type
Working Temperature
-4°F ~ 131°F / -20°C ~ 55°C
IP Rating
IP55
Mounting Type
Recessed Surface Surface Surface
Dimension
9.06x5.91x1.69 in 230x150x43 mm
3.54x5.12x1.69 in 90x130x43 mm
2.17x5.12x1.54 in 55x130x39 mm
2.95x7.48x1.77 in 75x190x45 mm
*Specifications are subject to change without notice
Page 7
18
CODE ACCESS FOR NC-DS2-KP
The original factory defaulted Programming / Master Code is 1234. Input a 4 digit password to have the door strike or the lock unlocked.
Change the Master Code
1. Shut down the power of the unit by pressing down and holding the
button.
2. Press the
button again to turn on the unit; a long continuous tone will sound.
3. When the tone stops, another tone will beep. Enter the new 4 digit Master Code.
Entering Programming Mode
1. Press the
button plus enter your 4 digit Master Code.
2. You have successfully entered the programming mode when the unit beeps three sounds and the LED is flashing.
3. Press the
button to quit.
Set the Unlocking Time
Factory default setting is 5 seconds.
1. Enter programming mode.
2. Enter 00 (this is a special code group); the unit will beep two “Di Di” sounds as a reminder.
3. Enter a 2 digit desired lock/delay operation time (01 to 99 seconds).
4. Press the button to exit.
Add User Codes
1. Enter programming mode.
2. There are 40 group codes to choose from: 01 to 40. It should be inputted in front of the 4 digit codes from 31 to 40 group codes. Input once 4 digit codes to open the door for a long time until twice the same code to have it closed.
3. Input the 4 digit code. If the unit beeps two sounds, it is unsuccessful. If it beeps three sounds, then the User Code is successfully set.
4. Press the
button to quit.
Delete User Codes
1. Enter programming mode.
2. Enter one of the code groups from 01 to 40.
3. Press the # button to delete the codes of which position you just inputted. E.g. input 01, means delete the codes on the position 01
4. The code is successfully deleted when the unit beeps three “Di Di” sounds as a reminder.
5. Press the
button to quit.
Delete a Code Directly
1. Enter programming mode.
2. Press the # button; the unit will beep two “Di Di” sounds as a reminder.
3. Input the 4 digit code that you want to delete.
4. It is successfully deleted after the unit beeps three sounds.
5. Press the
button to quit.
7
APPLICATION DIAGRAM
NOTE: Power supply (AC-POWERDC) sold separately.
PARTS & FUNCTIONS – COLOR IR CAMERA OUTDOOR STATION
No. Name Description
1 Water Cover Protect the camera from outside water
2 LED Assistant
Provide lighting during night time for better visibility
3 CCD Camera Capture the image to send to the monitor
4 Speaker Sound from the monitor is delivered
5 Calling Button Call the indoor phone to communicate
6 Microphone
Delivers and sound voice when communication with the indoor phone
7 Screw Hole Install the screws
8 Name Plate Show residential name
9 Connection Wiring Connection with the monitor
Page 8
8
NC-DS2
NC-DS2-ST
NC-DS2-SLIM
17
3. Communication Among The Optional Monitors & Audio
* Dialogue among the monitors, outdoor stations, and audio is possible only when the image of the visitor is displayed on the monitor screen.
Page 9
16
2. Monitor
9
NC-DS2-KP
c Requires a separate power supply
Additional: A. Light Sensor B. LED Indicator C. Keypad Access
* Pass Code
Door Lock
Page 10
10
PARTS & FUNCTIONS - COLOR MONITOR INSIDE STATION
NC-MON4 & NC-MON4-SUB
No. Icon Description No. Icon Description
1 Microphone 7 Speaker
2
Monitor 8
Talking Volume
3
Hang Off 9
Brightness
4
Door Lock Releasing 10
Chrome/Contrast
5
Talking 11 System Terminal
6 TFT Display/CRT 12
Calling
NC-MON4 - Main
15
OPERATION
1. Visitor Call
Page 11
14
NC-DS2-KP
NC-MON4 & NC-MON4-SUB
Instructions:
1. System Cable: Non-STP core cable, wire >
0.5mm2, from Outdoor Station to
the farthest monitor <
200ft / 70m.
2. Each monitor should be paralleled. One Main monitor can extend up to 3 Sub monitors. One Main monitor can connect to a maximum of 2 Outdoor Stations.
3. The handset monitor only has 2 function buttons.
4. Each Video Door Phone is 12V DC~14.5V DC / 1.3A.
11
NC-MON4-SUB
AUDIO PHONE SET PARTS & FUNCTIONS
NC-APS
Page 12
12
WIRING CONNECTION SYSTEM DIAGRAM
c Requires a separate power supply Note: Socket CN1 is just retained for outdoor station in alone system (like as an outdoor
unit is matched with an indoor unit). Please recheck the polarity of CN1 and have the 4­wire connected as per the enclosed label
1. Red: Voice
2. Blue: Ground
3. Yellow: Power (12V DC)
4. White: Video
Door Lock
13
INSTALLATION
NC-DS2
NC-DS2-ST
NC-DS2-SLIM
Loading...