Sentry ST-677 Instruction Manual

Page 1
Infrared Thermometer
T
E
E
R
M
H
D
M
S
R
I
E
N
H
F
T
R
A
D
R
E
ST-677ST-677
HDS Infrared Thermometer
Instruction Manual
Page 2
Page 3
Instruction
Manual
Version-01 07/MAY.
Page 4
1.Product Introduction
1-2 Applications
2.Safety Information
2-2 Safety symbols
3.Specifications
4.Operation Instructions
Unit Diagram
Function
5.Techniques of Infrared Thermometer
6.Maintenance
1-1 Features
2-1 Cautions
4-1 Quick Start
4-2
4-3 Operation
4-4 °C/°F,Laser Switch and Battery Change
5-1 Field of view(FOV) ratio
5-2 Emissivity
Table Content
1
2
3
4
1 1
2 2
4 4
6 8
9 9
10 10
Page 5
1. Product Introduction
Thank you for purchasing this infrared thermometer. The
infrared thermometer is a non-contact infrared
temperature measuring instrument. To measure a
temperature , point the unit at the object until the
temperature is read , pull the measuring trigger and
hold. Make sure the target area is larger than the unit's
spot size. For large target objects assure you are within
target distance.
1-1 Features
Features with board temperature and high DS ratio.
These allow user to monitor the target temperature for a
long distance, far away from the potential risk.
H
igh DS ratio.
Adjustable emissivity from 0.1 to 1.00 in 0.01 steps.
Ultra low power consumption in shutdown mode.
Extended long time measuring reliability.
Laser sighting On/Off is switchable.
Backlit LCD display.
°C or °F selectable.
Electronic trigger lock.
1-2 Applications
Electrical troubleshooting.
Automotive repair and maintenance.
Air conditioner.
Science experiment.
Manufacturing processes of semiconductor technology.
Test terminals on circuits.
Food safety and processing.
Perform HVAC energy audits.
1
Page 6
2
2. Safety Information
Laser Warning Note!
Read the following safety information carefully before attempting to operate or service the meter. Only qualified personnel should perform repairs or servicing not covered in this manual.
EN61326: Electrical equipment for measurement, control and laboratory use. IEC61000-4-2: Electrostatic discharge immunity test. IEC61000-4-3: Radiated ,radio-frequency, electromagnetic
field immunity test.
IEC61000-4-8: Power frequency magnetic field immunity test.
Tests were conducted using a frequency range of 80-1000 M Hz with the instrument in three orientations.The average
o o
error for the three orientations is ±0.5 C (±1.0 F) at 3V/m throughout the spectrum. However, between 781-1000MHz at 3V/m, the instrument may not meet its stated accuracy.
Dangerous, refer to this manual before using the meter.
CE Certification.
D o n o t p o i n t l a s e r d i r e c t l y a t e y e . U s e c a u t i o n a r o u n d r e f l e c t i v e s u r f a c e s . K e e p o u t o f r e a c h o f c h i l d r e n .
The device may not be disposed of with the trash.It promotes the re-use recycling and other forms of recovery of used materials and components, and to improve the environmental performance of all operators ( manu facturers, traders and treatment facilities) involved in the life cycle of products. Dispose of the product appropriately in accordance with the regulations in force in your country.
2-1 Cautions!
DO NOT submerge the unit in water.
This product is not designed for use in medical evaluations. The product can only be used to measure body temperature simply for reference. They are meant for industrial and scientific purposes.
2-2 Safety symbols
This instrument conforms to the following standards:
Page 7
3
3. Specifications
Temperature Range -32~1650 (-25.6~3002ºF)
Accuracy
±3.0ºC(±5ºF) from -32~-20ºC(-25.6~-4ºF)
±2.0ºC(±3ºF) from -20~100ºC(-4~212 ºF),
±2% from 100~1650ºC(212~3002ºF)
Th er mo p il e 8 ~1 4μm
Re pe a t a bi li ty ± 1º C ( ± 2º F)
Re so l u t io n
Re sp o n s e Ti me 500 ms
Em is si v it y Ad ju st ab le 0 .1 ~ 1. 0
Di st an c e/ Sp ot R at io 50 : 1
Su pp l y Vo lt ag e 9 V
at i a l r
m c l pp
Au to P ow er O ff A ut a f t a rox 6s
o
e
y
Op er at i ng Tem p. 0~ 5 0(3 2~ 12 2), 10 ~9 0% R H
°C / °F S w i tc ha bl e
YE S
Ba ck li g ht YE S
Laser S igh t S witchabl e YES
Ma x/ Mi n /Av g/ΔT YE S
10 P oi nt M em or y Y ES
Au di o Al a rm Y E S
Au to M ea su ri ng Y ES
Du al D is pl ay YE S
Tri po d Mo un t Y ES
Di me n s i on s 2 00 x1 6 6x 51 mm
We ig ht 2 8 0 g Ap pr ox .
0.1°C or 0.1°F (Above 2000°F:1°F)
Page 8
Measuring Window
4. Operations of Instrument
4.1 Quick Start
To measure a temperature , point the unit at the target,
pull the trigger and hold. Be sure to consider the
target area inside the angle of vision of this instrument.
The single spot of laser is used for aiming only.
4-2 Unit diagram
4
Measuring Trigger
Display Screen
Laser Sighting
Battery and Cover
Control Panel
Page 9
LCD & Control panel
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SCAN / HOLD / AUTO
°C / °F Indication
Main Temperature Display
Max / Min / Avg
Set / Record Value
Lock Key
Mode Key
Up Button
Laser / Buzzer On / Off
Low Battery
Data Log
ΔT / Emissivity
High / Low Alarm
Memory Key
Down Button
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Page 10
4.3 Operation Functions
To operate more advance functions, it is simply by using
MODE button to change. The sequential operations and
the corresponding explanations are shown in the following
flow-chart.
Operation Mode
6
Mode
SCAN
MIN
AVG
T
HAL
LAL
Par ameter Setup mode
Scan and di splay the temperature during measurement.
The maximum temperature within one shot measuring..
The minimum temperature within one shot measuring.
The average temperature within one shot measuring.
The highe st and lowest temperatur e differenc e within one shot mea suring
Recall th e stored data by using
or button.
Emissivity for more accuracy
on differen t materials.
Highest a larm temperature setti ng.
Lowest al arm temperature settin g.
(* The parame ters are adjusted b y using or buttons .)
.
DATA
MAX
Page 11
Remarks
a. Memory: Activate the record function by push the M button.
To delete all the records, press up or down button to DATA0
and press “M” button.
b. LOCK: Push the button to continuously measure and
display the temperature without pull the measuring trigger.
c. The above functions can be activated always in any step of
operations mode in flow-chart.
d. In SCAN mode, the LCD displays both the current tempera-
ture in Celsius or Fahrenheit. The unit will HOLD the last
reading for 30 seconds after the trigger is released. When
the battery is low, the battery icon is display, but the unit will
continue to function.
e. While DATA# flashes on the left bottom, the value on the
main Temperature Display can be recorded in “#” log. Simply
press “M” button.
7
Page 12
4.4 °C/°F, Laser Switch and
Battery Change
8
The unit is powered by 9V battery and displays temperatures in either C or F. The user has to replace the battery when the battery voltage drops below the voltage for reliable operation and at the same time the low battery symbol will appear.
To change the 9V battery, pull open the unit's handle under the trigger. After replacing the battery push back and snap in place.
° °
°C / °F
Switch
Laser on/off
9V Battery
Battery cover release button
Page 13
5. Techniques of Infrared rmometer
The
9
5.1 Field of View (FOV) ratio = Distance to Diameter (DS) ratio
The field of view is the angle of vision at which the
instrument operates , and is determined by the optics
of the unit. The FOV is the ratio of the distance from the
target to the target diameter. The smaller the target , the
i
m e
closer you should be to it . When the target dia et r s
small, it is important to bring the thermome ter closer to the
t
targe to insur t hat on y the target i s measured,e xcluding
l
e
the surroundings.
Page 14
5.2 Emissivity
10
6. Maintenance
Cleaning the lens: Blow off loose particles using clean
compressed air. Gently brush remaining debris away
with a camel's hair brush. Carefully wipe the surface
with a moist cotton swab. The swab may be moistened
with water.
NOTE:
DO NOT use solvents to clean the lens.
Cleaning the housing:
Use soap and water on a damp sponge or soft cloth.
Non-contact temperature sensors measure IR energy emitted by the target, have fast response, and are commonly use to measure moving and intermittent targets, targets in a vacuum, and targets that inaccessible due to hostile environments, geometry limitations, or safety hazard. The cost is relatively high, although in some cases is comparable to contact devices.
Emissivity is the ability of an object to emit or absorb energy. Perfect emitters have an emi ssi vi ty of 1 , emitting 100% of incident energy. An object with an
emissivity of 0.8 will absorb 80% and reflect 20% of
ra
the incident energy. Emissivi y is defined as t he tio
t of the energy radiated by an object at given temperature to the energy emitted by a perfect radiator at the same temperature. All values of emissivity fall between 0.0 and 1.0.
Page 15
Emissivity Table
Material
Temp C/ F ° ° Emissivity
Gold(pure highly polished) 227/440 0.02 Aluminum foil
27/81 0.04 Aluminum disc 27/81 0.18 Aluminum household(flat) 23/73
0.01
577/1070
0.06
Aluminum(rough plate) 26/78
0.06
Aluminum(oxidized @599 C)° 199/390
0.11
599/1110
0.19
Aluminum surfaced roofing 38/100
0.22
Tin(bright tinned iron sheet) 25/77
0.04
Nickel wire 187/368
0.1
Lead(pure 99.95-unoxidized) 127/260
0.06
Copper 199/390
0.18
599/1110
0.19
Steel 199/390
0.52
599/1110
0.57
Zinc galvanized sheet iron(bright)
28/82
0.23
Brass(highly polished): 247/476
0.03
Brass(hard rolled-polished w/lines): 21/70
0.04
Iron galvanized(bright) -
0.13
Iron plate(completely) 20/68
0.69
Rolled sheet steel 21/71
0.66
Oxidized iron 100/212
0.74
Wrought iron 21/70
0.94
Molten iron 1299-1399/3270-2550
0.29
Copper(polished) 21-117/70-242
0.02
Copper(scraped shiny not mirrored) 22/72
0.07
Copper(Plate heavily oxidized) 25/77
0.78
Enamel(white fused on iron) 19/66
0.9
Formica 27/81
0.94
Frozen soil -
0.93
Brick(red-rough) 21/70
0.93
Brick(silica-unglazed rough) 1000/1832
0.8
Carbon(T-carbon 0.9% ash) 127/260
0.81
Concrete -
0.94
Glass(smooth) 22/72
0.94
Granite(polished) 21/70
0.85
Ice 0/32
0.97
Marble(light gray polished) 22/72
0.93
Asbestos board 23/74
0.96
Asbestos paper 38/100
0.93
371/700
0.95
Asphalt(paving) 4/39
0.97
Aluminum (polisned prate 98.3%) 227/400
0.04
11
Page 16
Page 17
Page 18
ST 677 Version-01 07/MAY.
3F, No.122, Sec.1, Sanmin Road,
Ban-Ciao, Taipei 220, Taiwan, R.O.C. TEL:886-2-2956-8198 FAX:886-2-2956-7662 http://www.sentrytek.com.tw
PA05-0000677-01
Loading...