If there are any visible signs of product
damage, contact Sentry or your
authorized product distributor
immediately.
Mounting
3.
7 - 9’
2 - 2.75 m
The ideal placement for the unit is at a
height between 7’ and 9’ (2-2.75 m).
Install with the mounting tabs at the top.
Activate the product
2.
To activate the Collision Sentry Corner
Pro, pull out the plastic battery tab
located inside the unit. Remove the door
on the front of the unit, pull the tab and
replace the door. This activates the three
(3) “D” cell batteries that are included
with each unit. The LED lights will begin
blinking as the device becomes oriented
to the environment. During this warm-up
period, the blue low battery indicator
also flashes.
Note* - Always activate the unit prior to installation. Pull the tab, close the door and
the install the unit to the upright.
Installation on racking or metal
4.
corner
Use the integrated magnets on the back
to “snap” the unit to a metallic corner or
rack.
Tether to rack or corner
5.
The included nylon tether provides extra
security when mounting the unit using
the magnets. Using the tether is optional
but recommended.
Installation on non-metallic
6.
corners
Use the integrated mounting tabs to
install the unit directly to non-metallic
surfaces.
Collision Sentry Corner Pro is now ready for use
7.
The product needs about 20 seconds to
acclimate to the new environment and
“learn” its new surroundings. During
this warm-up, the warning lights will
flash. The lights will go solid red for four
seconds at the end of the warm-up
period. This indicates the product is
ready to use.
Form 102019 – 5M – 10/2019
Alarm adjustments
8.
Collision Sentry Corner Pro ships with the audio alarm
activated and set to the highest volume. This alarm can be
adjusted using the switches found inside the unit and located
below the battery compartment. (See illustration). There are
two switches used for adjusting the volume – a high/low
switch and an off/on switch.
1. Remove the door on the front of the unit.
2. Alarm switches are located below the battery compartment.
3. Adjust the switches to the desired setting.
4. Reinstall battery door.
5. Unit is now ready for use.
For further details and trouble-shooting
please refer to online documentation.
Go to: www.sentrypro.com
Normal Operation
When motion is detected on both sides of the corner, the LED
lights flash and the alarm sounds. The flashing and beeping
continue until 1.6 seconds after motion has stopped. Both
alarms – audio and visual – can be individually engaged or
disengaged. (See instruction 8)
Low-Battery
1. Depending on usage, in regard to the battery life of the three
(3) “D” cell batteries, all estimates point to a minimum of
twelve (12) months.
2. When battery voltage drops below a specified threshold, a
blue light on the front of the Collision Sentry flashes and
beeps. Install new batteries.
3. Note – when the low battery light activates, the Collision
Sentry continues to function for a short period of time. The
life cycle of the batteries depends on usage.
4. TO ENSURE FULL PROTECTION, CHANGE BATTERIES AS
SOON AS THE LOW-BATTERY SIGNAL FLASHES AND BEEPS.
Changing Batteries
The Collision Sentry Corner Pro operates on three (3) standard
“D” cell batteries that are easily replaceable.
1. Remove door on front of Collision Sentry Corner Pro unit.
2. Remove old batteries.
3. Insert new batteries in same orientation as the originals.
4. Reinstall door.
5. The unit is now ready to use.
Collision Sentry® Corner Pro Limitation
1. Collision Sentry Corner Pro is a motion sensor device that
works when both sensors detect movement at the same
time. Any factor that limits the sensors’ ability to see or
detect a change in infrared light, limits or prevents the
product from working properly. These factors include:
a. Objects blocking the sensors’ field of vision.
b. If vehicles or pedestrians do not exhibit any infrared
signature (highly unlikely, but possible) the sensors may
have trouble detecting motion. This will limit product
effectiveness.
c. Ambient temperature in the facility can affect the
sensitivity of the sensor.
d. Objects moving very slowly may not be detected.
2. The presence of certain (strong) electrical fields in the
environment could cause the Collision Sentry Corner Pro to
momentarily false alarm. In the (rare) event that interference
occurs, the user can try to mitigate the interference by
re-orienting or relocating the Collision Sentry Corner Pro or
by increasing the separation between the Collision Sentry
Corner Pro and the source of the interference.
3. Collision Sentry Corner Pro is designed for INDOOR USE only.
4. Collision Sentry Corner Pro is a collision warning system
designed to supplement safety procedures already in place.
Its use does not replace or eliminate the need for forklift
operators and pedestrians to use extreme caution when
maneuvering through the facility.
5. Proper training is vitally important when deploying Collision
Sentry Corner Pro. A thorough understanding of how the
product works, what the signals indicate, the features and
limitations is needed to maximize the product’s effectiveness.
We highly recommend testing the Collision Sentry Corner Pro
on-site to determine the fitness of the product for use in your
facility.
Limited Warranty Statement
Limited Warranty:
Sentry Protection LLC warrants that its products will be free of defects in materials or workmanship for one (1) year after delivery of the
product to the initial end-user. Sentry Protection LLC will, at its option, repair or replace without charge the Sentry product determined by
Sentry Protection LLC to be defective in material or workmanship. Any defects in materials or workmanship must be reported immediately to
either Sentry Protection LLC, or the seller of the Sentry product. Failure to provide timely notice so as to permit effective repair or replacement
shall void this limited warranty. This limited warranty covers materials, workmanship, and delivery of the product to the facility. Any damage to
the product due to shipment or delivery must be reported within 24 hours of the delivery of the product. This limited warranty shall only apply if
the product has been installed, maintained and used in accordance with manufacturer guidelines and specifications, and has not been subject
to mishandling, misuse, abuse, neglect, accident, improper maintenance, improper installation, improper use, alteration, fire, water or damage
because of other perils or natural disasters.
Exclusive Warranty:
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR REMEDIES, WHETHER WRITTEN OR ORAL OR
IMPLIED. ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, COURSE OF DEALING OR
USAGE OF TRADE ARE HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED.
UNDER NO CIRCUMSTANCES SHALL SENTRY PROTECTION LLC BE LIABLE FOR ANY DIRECT OR INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL LOSS OR DAMAGES OF ANY KIND, INCLUDING BUT NOT LIMITED TO ANY CLAIMS FOR LOSS OF PROFITS, LOSS OF
REVENUES, LOSS OF OPPORTUNITIES, THE CLAIMS OR COSTS OF THIRD PARTIES, OR INJURY OR DAMAGE TO PROPERTY OTHER THAN TO
ITS OWN PRODUCT. IN NO EVENT WILLTHE END-USER’S RIGHT OF RECOVERY EXCEED THE PURCHASE PRICE OF THE PRODUCT.
Because of the nature of this product, its inherent use in abusive environments, and the unpredictability of the hazards it may face, Sentry
Protection LLC, does not warrant the ability of the Sentry products to perform in any way. All decisions regarding the fitness for use or
performance of the products are the responsibility of the buyer of the product. Sentry Protection does offer a 30-day trial program so those
prospective buyers of its products have a method to determine for themselves this fitness for use. If you have questions about the details of
this 30-day trial program, please contact your distributor or your Sentry Protection Products representative.
EU Declaration of Conformity
Declaration: The listed product is in conformity with the following Directives:
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of
the Member States relating to electromagnetic compatibility (recast).
Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain
hazardous substances in electrical and electronic equipment (recast).
This declaration of conformity is issued under the sole responsibility of the manufacturer.
Manufacturer: Sentry Protection LLC, 16927 Detroit Avenue #3 Lakewood, OH 44107 USA
Model Name: Collision Sentry®
Model Number: CLN-200
Serial Number(s): various
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation,
using the following harmonised standards:
EN 61000-6-2:2005 Electromagnetic compatibility - Part 6-2: Generic standards - Immunity for industrial environments
EN 61000-6-4:2007 Electromagnetic compatibility - Part 6-4: Generic standards - Emission standard for industrial environments
+Al: 2011
EN 55011:2009 Limits and methods of measurement of radio disturbance characteristics of industrial, scientific and medical
+Al:2010 (ISM) radio-frequency equipment - Group 1 Class A
The product is in conformity with Directive 2014/30/EU based on test results referencing harmonised standards and the use of a Technical File as
detailed in Module A of Annex 11, and fulfilment of the essential requirements set out in Annex I in accordance with Article 14 of the Directive.
Signed for and on behalf of Sentry Protection LLC by:
Signature:
_______________________ James P. Ryan, President April 29, 2019
Place: Sentry Protection LLC, 16927 Detroit Avenue, Suite 3, Lakewood, Ohio 44107 USA
Instrucciones de instalación y uso
Dispositivo de advertencia de colisión
Collision Sentry® Corner Pro
Retirar del paquete
1.
Si hay signos visibles de daños en el
producto, comuníquese inmediatamente
con Sentry o con su distribuidor de
productos autorizado.
Montaje
3.
7 - 9’
2 - 2.75 m
La ubicación ideal para la unidad es a
una altura entre 7’ y 9’ (2-2, 75 m). Se
debe instalar con las pestañas de
montaje en la parte superior.
Activar el producto
2.
Para activar el Collision Sentry Corner Pro,
extraiga la pestaña de plástico de las pilas
que encontrará en el interior de la unidad.
Retire la tapa de la parte frontal de la unidad,
extraiga la pestaña y vuelva a colocar la
tapa. Esto activa las tres pilas de celda (3)
“D” que se incluyen con cada unidad. Las
luces LED empezarán a parpadear a medida
que el dispositivo esté orientado hacia el
entorno. Durante este periodo de
calentamiento, el indicador de batería baja, de color azul, también parpadea.
Nota* Siempre debe activar la unidad antes de la instalación. Extraiga la pestaña,
cierre la tapa e instale la unidad recta.
Instalación en estanterías o
4.
esquinas metálicas
Use los imanes integrados en la parte
posterior para ‘ajustar’ la unidad a una
esquina metálica o estantería.
Fijar a estantería o a esquina
5.
La fijación de nailon incluida proporciona seguridad adicional cuando se monta
la unidad con los imanes. El uso de la
fijación es opcional, pero recomendada.
Instalación en esquinas no
6.
metálicas
Use las lengüetas de montaje integradas
para instalar la unidad directamente en
superficies no metálicas.
El Collision Sentry Corner Pro ya está listo para su uso
7.
El producto necesita aproximadamente
20 segundos para aclimatarse al nuevo
ambiente y “aprender” sobre su nuevo
entorno. Durante este calentamiento, las
luces de advertencia parpadearán. Las
luces se encenderán durante cuatro
segundos en un color rojo sólido al final
del periodo de calentamiento. Esto indica
que el producto ya está listo para usar.