1. DESCRIPTION
1.1. Purpose
The purpose of this document is to provide necessary information for use by field personnel in the installation, operation, and troubleshooting of the 900MHz Cell Tower Gateway Basestation (TGB).
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
2
Page 4
1.2. FCC Class B Statement
“NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications to this device not expressly approved by
AMDS could void the user’s authority to operate the equipment.
1.3. Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
3
Page 5
1.4. Specifications
1.4.1. Input Power
1.4.1.1. Voltage
20-28VDC (nominally 24V)
1.4.1.2. Input Current
8A max Approximately 3A continuous
1.4.1.3. Alarms and Controls
Low-voltage alarm is asserted when output voltage drops below 22VDC.
Low-voltage disconnect is asserted when output voltage drops below 20VDC, re-connects when output voltage exceeds 22VDC.
1.4.2. Environmental
1.4.2.1. Operating temperature
-40˚C to +85˚C
1.4.2.2. Storage temperature
-40˚C to +85˚C
1.4.2.3. Humidity
0% to 95%, non-condensing
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
4
Page 6
General
The TGB Transceiver is a high performance burst data radio system. The RF receiver is configured to receive 3 distinct modulation schemes on 3 adjacent frequencies in the 896 to 940 MHz frequency range.
The TGB RF Transmitter operates on a single configurable channel (12.5kHz,
13.6 KHz, or 25kHz authorized bandwidth depending on the channel and FCC Rule section governing it’s operation) in the 935 to 960 MHz frequency range. The transmitter utilizes yet another type of modulation scheme, different from the three utilized by the receiver.
Transmitted and received data messages are short in nature, meaning that the radio is intended for burst telemetry type of applications. Larger packets may, however, be transmitted by sending successive packets.
The TGB operates as a multi-channel transceiver in a “cellular” type system. The TGB assembles the received messages and forwards them to the TGB
Controller (one per city) via local phone lines. The TGB Controller eliminates redundant messages (i.e., messages from endpoints that were received by more than one TGB) before forwarding them to the NOC via a high-speed connection (ISDN, T1, etc).
The TGB shall also notify the NOC of any alarm indications, such as tamper/intrusion, temperature alarms, or power failure.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
5
Page 7
1.5. Block Diagram
1.5.1. Power System
Hazardous AC voltages capable of producing severe electrical shock are present at various locations in the TGB. Exercise caution when working inside the enclosure, to assure that contact is not made with and electrical termination.
The batteries are a source of energy and can be hazardous if shorted. Exercise caution.
1.5.1.1. AC Power – Indoor
AC Power is supplied to the rectifier through a rack mounted power strip with integral ON/OFF switch and surge protection.
1.5.1.2. AC Power – Outdoor
AC Power enters the outdoor enclosure through the bottom of the cabinet. The rectifier plugs into the surge protected, GFI outlet located in the bottom of the cabinet.
!!! Danger !!!
!!! Warning !!!
1.5.1.3. DC Power
The rectifier converts commercial power (120/220VAC) to 24VDC power to the equipment chassis, heat exchanger, fans, intrusion alarm, and batteries. In the event of commercial power failure, the rectifier provides uninterrupted DC power by switching over to battery backup.
1.5.1.3.1. Fuses and Breakers
The TGB contains one 10A circuit breakers/disconnects—one to protect/control power to the electronics chassis.
1.5.1.4. Grounding
The ground bus bar MUST be connected to the site’s HALO ground using an insulated conductor of sufficient size. All transient voltage protectors (antenna, commercial power, TELCO lines) are grounded to this bus bar. Failure to properly ground the TGB equipment presents a risk to not only the TGB electronics, but other customers’ equipment at the site as well. A qualified electrician should perform connection. Consult a local electrician, or site engineer, for size requirements.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
6
Page 8
1.5.2. Wiring Diagram
A copy of the wiring diagram is included in the assembly drawing located at the end of this document.
1.5.3. Alarms
1.5.3.1. Intrusion
The enclosures are equipped with pin switches on both the front and rear doors that activate and intrusion alarm when a door is opened. The TGB notifies the TGB controller of the alarm. A feature of the outdoor enclosures intrusion switch is the ability to “pull out” the switch to cancel the alarm. The switch has a 30-minute mechanical delay, after which the intrusion alarm will again be asserted.
1.5.3.2. Temperature
The TGB is equipped with high (120F) and low (41F) temperature alarms. The TGB notifies the TGB controller of the type of alarm.
1.5.3.3. Power System
The rectifier has several alarm outputs to signal different types of faults associated with the power system.
Low Voltage Alarm – Asserted upon loss of AC Commercial Power. Rectifier Failure – Asserted when DC output voltage is out-of-range. Load Fuse Failure – Asserted when one of the load fuses (Fan, Heat
Exchanger, Intrusion Alarm) opens. Battery Failure – Asserted when output voltage drops below threshold, Low voltage disconnect is activated, or Bypass switch is in Bypass position.
1.5.4. RF Subsystem
1.5.4.1. Spark Gap
The antenna bulkhead connector is a Gas Discharge Tube Surge Arrestor designed to shunt lightening induced transients to ground; thereby protecting the TGB electronics from damage. The arrestor contains a replaceable gas tube element that should be inpected regularly are replaced as necessary.
1.5.4.2. Cavity Filter
The cavity filter is a frequency selective device designed to protect the RF front end from overloading by out-of-band signals. The cavity filter assembly is tuned and assembled as a unit. No cables or connectors should be changed/replaced, nor should any adjustments be made to the tuning screws.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
7
Page 9
1.5.4.3. RF Cabling
The RF cabling and connectors inside the TGB are selected due to their low-loss characteristics. No cables or connectors should be changed/replaced.
1.5.5. Electronics Assembly
The Electronics Assembly is the heart of the TGB radio. It contains all of the RF and signal processing electronics housed in a single card cage and provides for an interconnecting Backplane.
1.5.5.1. RF Assembly
The RF Assembly converts (using amplifiers, mixers and filters) the RF signal from the antenna to an IF signal used by the A/D Assembly, provides a high performance 1.25W Transmitter stage, and provides a programmable clock signal for the A/D card . It also provides AGC functions.
1.5.5.2. A/D Assembly
The A/D Assembly digitizes the IF signal from the Receiver Assembly. The digitized information is then delivered to the CPC Assemblies.
1.5.5.3. CPC Assembly
The TGB contains 2 dual channel CPC assemblies, supporting a number of different modulation schemes. The CPC assembly performs filtering and demodulation of inbound messages and delivers them to the fusion processor.
1.5.5.4. Fusion Processor Assembly
The Fusion Processor Assembly collects serial messages from all 4 CPC channels, combines them, and delivers them to the TGB Controller.
1.5.5.5. DC/DC Supply
The plug-in DC/DC Supply converts 24VDC Power to standard operating voltages (+3.3VDC, +5VDC, +/-12VDC).
1.5.6. Breakout Panel Assembly
The purpose of the Breakout Panel is to function as an interface between the Fusion Processor and the “external world”. It provides a termination point, and more importantly Transient Voltage Suppression, of signals coming into the Fusion Processor. TVS devices protect all Alarm Inputs, Modem Lines, and Ethernet Lines.
Signal I/O Function/Comments
POTS1
Bi-directional POTS Modem Connections POTS2 Diagnostic Bi-directional DB9 Female connector wired as a
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
8
Page 10
Port DCE Inputs 1-7 Inputs Contact Closure Alarm Inputs. Ethernet Bi-directional 10/100Base T Ethernet Port
2. Installation
2.1. Ventilation
The outdoor enclosure is completely sealed from the outside environment (NEMA 4). A heat exchanger is used to cool internal electronics. The indoor enclosure is designed to circulate ambient air for cooling. Fans inside the enclosure are designed to circulate air across the electronics and power supply.
2.2. Electrical Connections
2.2.1. Grounding
Ensure that all connections to the Ground bus bar are secure. The bus bar must also be connected to the site’s Halo Ground using the 8AWG Green/Yellow cable provided with the TGB System.
2.2.2. Power/Battery !!! Warning
!!!
Do not make any connections with power applied to the system. The batteries are a source of energy and can be hazardous if shorted. Exercise caution.
Prior to connecting batteries, disconnect the battery cable from the right hand side of the rectifier cabinet. Install batteries and connect jumpers to battery terminals. Before reconnecting battery cable to right hand side of rectifier cabinet, measure open circuit voltage between pins 1 & 2. The voltage should be above 24VDC. If the voltage is below 22VDC, do
not proceed with connection—batteries must first be charged before installation.
2.2.3. Antenna
The antenna connection is a Type-N female located on the top of the indoor cabinet (bottom of the outdoor cabinet). The connector is a bulkhead mounted surge arrestor rated at 90V.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
9
Page 11
2.2.4. Data Link
The TGB supports several different communications backbones—a single/dual modem (56K) connection or a 10/100BaseT Ethernet connection. The modems and Ethernet connections are made through the modular connectors on the breakout panel.
2.3. Initial Startup
Prior to applying power, ensure that all fuses are in place, the antenna is connected and the data line (POTS or Ethernet) is connected.
After approximately 30 seconds, the Fusion Processor will complete its boot up procedure, and the TGB will connect to the TGB Controller.
3. Operation
3.1. General
The TGB is designed to operate with minimal user intervention—even in the event of commercial AC power interruption. Software in all programmable devices can be uploaded, temperature and alarm status can be monitored, and control parameters modified—all from a remote site via the internet.
3.2. Starting and Stopping
Prior to powering down the TGB Electronics, the Halt command should be issued to the Fusion Processor. After the Fusion Processor has completed shutdown, the TGB Electronics can then be powered-down by switching the Chassis breaker/disconnect to the OFF position. To start the TGB Electronics simply switch the Chassis breaker/disconnect to the ON position.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
10
Page 12
3.3. Indicators Indicator Location Description
INPUT OK Power Supply GRN – Input voltage within normal
operating limits
FAULT Power Supply RED – Output Voltage Fault
GRN – Fusion Processor Power OKPOWER Fusion Processor OFF – Fusion Processor Power Fail RED – Alarm Input Active IN1 thru IN7 Fusion Processor OFF – Alarm Input not Active
TRIP CPC Flash RED – Trip Detected MSG CPC Flash AMBER – Valid Message
Received GRN – CPC Power OK OK CPC OFF – CPC Power Fail
RED – System RESET Asserted RESET A/D OFF – System OK GRN – A/D Power OK POWER A/D OFF – A/D Power Fail
OTR A/D Flash AMBER – Input Over-range
GRN – Receiver Power OK POWER Receiver OFF – Receiver Power Fail AMBER – Synthesizer Locked LOCK Receiver RED – Synthesizer Unlocked
GRN – AC Power OK AC POWER OFF – AC Power Fail RED – DC Output Voltage Out of Range
OK RECTIFIER
FAILURE
Rectifier Rectifier
OFF – Normal Operation RED – Load Fuse Failed LOAD FUSE OFF – Normal Operation RED – Output Voltage Low, or
Low Voltage Disconnect
FAILURE BATTERY
FAILURE
Rectifier Rectifier
Activated, or Switch in BYPASS
OFF – Normal Operation
Shaded areas indicate Normal Operation.
3.4. Low Voltage Alarm and Disconnect
Upon Commercial AC Power Failure, the TGB will immediately notify the network via the AC POWER Alarm; at which time the system will begin operating on battery backup. After duration determined by capacity of batteries, charge state, temperature, and current draw, the output voltage of the batteries will decrease.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
11
Page 13
The system provides for local visual (BATTERY FAILURE) and remote indication the system output voltage has fallen below a preset level. This level is set at the factory at 24V. The alarm clears automatically when the system output voltage increases above this level. The Low Voltage Alarm is the final indication that the TGB system is about to shut down. Once asserted the TGB will shutdown in approximately 8 hours unless commercial AC power is restored..
4. Maintenance
4.1. General
The TGB is designed to require minimal maintenance. Care should be taken to observe the appropriate precautions when working inside the TGB enclosure.
!!! The circuit cards used in this equipment contain static sensitive devices. Observe precautions for handling ESD sensitive items. A, ESD wrist strap is located inside the front door of the TGB enclosure.
4.2. Preventative or Routine Maintenance
4.2.1. Surge arrestor
The antenna surge arrestor is of the gas discharge tube type. A gas tube element may not always show outward signs of failure or degradation, therefore routine maintenance and inspection is recommended. The gas tube element can be replaced by simply removing the nut and replacing the element. If the number of thunderstorms in an area is high, gas tubes should be inspected more frequently. Gas tube degradation is dependant on the number of strikes as well as the intensity of the strikes. As obvious as it may seem, gas tube elements should never be inspected, or replaced, when a thunderstorm is approaching or occurring.
4.2.2. Airflow
Without adequate airflow, TGB performance may degrade due to increased temperature. At least once per year, the TGB enclosures should be checked for proper airflow. This includes verifying operation of all fans and ensuring that any air filters are free of dust and dirt.
4.3. Circuit Card Installation/Replacement
!!! The circuit cards used in this equipment contain static sensitive devices. Observe precautions for handling ESD sensitive items. A, ESD wrist strap is located inside the front door of the TGB enclosure.
Before replacing any circuit cards in the TGB Electronics Assembly (Chassis), first halt the Fusion Processor, then after it has successfully shutdown, switch the circuit breaker/ disconnect to the OFF position. Once the circuit cards
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
12
Page 14
are replaced, switch the circuit breaker/disconnect to the ON position to restart.
4.4. Battery Replacement
!!! Warning !!!
The batteries are a source of energy and can be hazardous if shorted.
Exercise caution.
The batteries are rated for a 5-yr life at 25˚C and 27.5VDC float voltage. Extended periods of operation above 25˚C will reduce battery life (rule of thumb: 50% life reduction per every 10˚C increase. After this time it is appropriate to have a change-out program. In the event of frequent deep discharges it is possible that the batteries may require earlier replacement.
Prior to disconnecting batteries, disconnect the battery cable from the right hand side of the rectifier cabinet. Remove jumpers from the battery terminals and remove old batteries. Install new batteries and reconnect jumpers. Before reconnecting battery cable to right hand side of rectifier cabinet, measure open circuit voltage between pins 1 & 2. The voltage should be above 22VDC. If the voltage is below 22VDC, do not proceed with connection—batteries must first be charged before installation.
4.5. Battery Recharging
!!! Warning !!!
The batteries are a source of energy and can be hazardous if shorted.
Exercise caution.
The shelf life of the batteries is 6 months from the date of charge. If the battery has been stored for more than 6 months, it should be recharged prior to installation.
To be used only for the purpose for which it is submitted. All rights reserved to AMDS LLC. Reproduction without written
consent is prohibited.
13
Page 15
5. Ordering Information and Parts List
5.1. Spares Kit
Description Manufacturer Part Number
Antenna Surge Arrestor Andrews APG-BNFNF-090 Gas Tube Andrews GASTUBE-090 Generator Plug Hubbell 2713
Bussmann GMT - 1 1/3 A 1 1/3A GMT Fuse Littlefuse HB481001.33 Bussmann GMT - 2 A 2A GMT Fuse Littlefuse HB481002 Bussmann GMT - 5 A 5A GMT Fuse Littlefuse H481005