Sensus Metering Systems SONIXIQ User Manual

QUICK GUIDE
SonixIQ
Quick Guide
The SonixIQ is a solid state residential gas meter, providing pinpoint accuracy of ultrasonic measurement and no moving parts to replace or wear out over time. Available
FEATURES

250CFH or 400 CFH meter class options

Live temperature compensation


Alarm notifications

Configurable volume pulse output

Configurable scrolling LCD display

20-year battery life

FlexNet SmartPoint® inside (available with or without)
IDENTIFICATION
The SonixIQ meter with the FlexNet module will have a visible label containing the following information:

Model: SONIXIQ

FCC ID: SDBSONIXIQ

IC: 2220A-SONIXIQ
with or without an integrated FlexNet® radio, the SonixIQ covers both 250 or 400 CFH needs.
The SonixIQ has an LCD display that supports walk up readings and status, an optical port that can be used with the SonixCom tool for configuration, a pulse output, and an optional integrated radio for communication across the Sensus FlexNet system.
Application and Safety
The SonixIQ should be used with clean, dry natural gas or air only. The meter electronics are enclosed in a vented case that provides both weather and EMC protection.
Only suitable non incendive circuits and non incendive field wiring should be connected to the field wiring terminals via the pulse cable.
Meter Specifications
SonixIQ 250 series 400 series
Capacity 250 to 299 cfh at 1/2” differential 400 to 450 c fh at 1/2”
Connections 20LT connections on 6” center to
center
MAOP 10 psig
differential
30LT connec tions on 6” center to center
Dimensions 9.94” L x 4.38” W x 7.89” H (25.25cm L x 11.13cm W x 20.04cm H)
Weight 6.3 lb (2.86 kg)
Operating Temperature
Humidity 0 to 95% relative humidity operating and storage (non-condensing
-40° to +150°F (-40° to +66°C)
and condensing)
GQG-10004-01
SonixIQ
Quick Guide
Basic Installation
Meter options are set at the factory and are determined according to the order specifications.
1. Shut the gas off at the inlet and outlet valves and remove the existing meter if present.
2. Connect the new SonixIQ to the pipe connections using an appropriate wrench.
3. Open the inlet and outlet valves to allow gas to flow through the meter.
4. Read the meter alarm status via the LCD display to confirm there are no active alarms.
5. If an initial reading is required at time of installation, the volume totalizer should be set to initial reading. Connect a handheld tool (HHD) running FieldLogic to the optical port to initiate the meter with a known reading.
Configure the FlexNet SmartPoint Module with FieldLogic
The FlexNet SmartPoint module is embedded in the SonixIQ as an option. If ordered, the SmartPoint module is already configured to the appropriate frequency. Once the SmartPoint module is activated, the SonixIQ can send messages through the FlexNet AMI system.
1. Connect a handheld tool (HHD) running FieldLogic to the optical port of the SonixIQ.
2. Launch FieldLogic Tools.
3. Enter the FlexNet ID of the SmartPoint Module, tap Start Connection, and then Activate and Configure as desired.
Note: e FlexNet ID is on the front cover of the SonixIQ.