iCon™ Form 2S and Form 12S Meters Physical Description
FCC Compliance
NOTE:
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures;
– Reorient or relocate the receiving antenna
– Increase the separation between the equipment and receiver
– Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected
– Consult the dealer or an experienced radio/TV technician
WARNING:
No party shall make any modifications or changes to the
MXU Model 530E (the equipment) without the express written consent
of Invensys Metering Systems. Doing so could result in the equipment
becoming non-compliant with the requirements of the Federal Communication
Commission Rules CFR47 Part 15 and could void the user’s
authority to operate the equipment.
Note: To comply with FCC RF exposure requirements in
section 1.1307, a minimum separation distance of 20 cm
(8 inches) is required between the antenna and all
persons.
FCC C
OMPLIANCE
Physical Description iCon™ Form 2S and Form 12S Meters
Physical Description
The iCon™ MXU 530-E Meter was designed to be assembled and disassembled
without the use of tools. This modular design allows you to upgrade or repair a unit
quickly and easily. The basic components of the iCon™ meter are depicted below and
detailed following the diagram.
POWER SUPPLY
BOARD
Base Assembly
The meter’s Base Assembly is molded from highly durable thermoplastics that provide
a stable platform for the meter’s Sensor Module, Register display board and up to two
additional option boards. The blades (or blade assembly) from the Sensor Module
extend through the Base Assembly to connect to the service socket of the main power
system.
Sensor Module
Power Supply
The iCon™ meter uses a capacitive tap to provide a regulated voltage to the Sensor
Module and the LCD display portion of the MXU 530-E board. The power supply can
withstand a voltage transient as described in IEEE C62.41, Level C and applied in
accordance with Section 5 of the ANSI C12.20-1998.
MXU 530-E
DISPLAY BOARD