Sensus Metering Systems IDTB005, IDTB006 User Manual

QUICK GUIDE
StratusIQ™
Quick Guide
The Sensus StratusIQ™ meter is a FlexNet™ integrated residential meter that includes multiple advanced features. The StratusIQ™ meter comes in a standard, transformer, or remote disconnect version and is available in a variety of forms.
SPECIFICATIONS
The StratusIQ meter with the integrated
FlexNet module will have a visible label stating
the model, FCC, and IC identifications.

Contains Model: IDTB005

Contains FCC ID: SDBIDTB005

Contains IC: 2220A-IDTB005
StratusIQ with FlexNet + Zigbee:

Contains Model: IDTB006

Contains FCC ID: SDBIDTB006

Contains IC: 2220A-IDTB006
Technical Overview
The StratusIQ meter is a technologically advanced meter with integrated
Sensus FlexNet capability. The FlexNet communications network offers
a simple, reliable, and secure system that is economical for mass
meter deployments, strategic deployments, and rural applications while
providing a multi-application solution for all AMI end points.
The StratusIQ meter incorporates several hardware modules on a single
assembly, including the FlexNet module, a power supply, an antenna,
an optical port interface, metering, and LCD display. The FlexNet radio
module enables the meter to transmit meter consumption and status
information at regular intervals.
The FlexNet module communicates via the FlexNet fixed wireless
telemetry network to provide electric meter readings and diagnostic data
from the meter to the utility provider via radio. The module contains both
a receiver and transmitter to allow for two-way communications over the
FlexNet network.
LCD
Register Reset
Optical Port
EQG-10008-01
StratusIQ™
Warnings & Hazards
WARNING
Sensus devices are for professional installation only. ey are to be serviced by professional personnel only. is product is NOT for consumer installation or servicing.
ATTENTION
Any modications made to this device that are not approved by Sensus may void the authority granted to the user by the FCC to operate equipment.
ATTENTION
is equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. ese limits are designed to provide reasonable protection against harmful interference in a residential installation. is equipment generates, uses, and can radiate radio frequency en­ergy and, if not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit dierent form that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
WARNING
If you are not sure of the rated power of your radio, contact your Sensus representative or dealer and supply the product model number found on the product label. If you cannot determine the rated power out, then assure 3-feet separation from the body to the device.
WARNING
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT RE­MOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO QUALIFIED SERVICE PERSONNEL.
RADIATION HAZARD
In order to satisfy the FCC RF exposure limit for transmitting devices, a separation distance of 20cm (7.87 inches) or more should be maintained while operating the Sensus IDTB005 and Sensus IDTB006. To ensure compliance, operation at closer than this distance is not recommended. is minimum safe distance is required between personnel and the antenna of this device.
RADIATION HAZARD
In order to satisfy the ISED RF exposure limit for transmitting devices, a separation distance of 22cm (8.66 inches) or more should be maintained while operating the Sensus IDTB005 and Sensus IDTB006. To ensure compliance, operation at closer than this distance is not recommended. is minimum safe distance is required between personnel and the antenna of this device. An de satisfaire à la limite d’exposition RF pour les appareils de transmission, une distance de séparation de 22cm (8.66 pouces) ou plus doit être maintenu pendant le fonctionnement du Sensus IDTB005 et Sensus IDTB006. Pour la conformité, un fonc­tionnement à distance inférieure à celle est pas recommandée. Cette distance minimale de sécurité est nécessaire entre le person­nel et l’antenne de cet appareil.
ATTENTION
is device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit ac­cepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
ATTENTION
is radio transmitter the Sensus IDTB005 and Sensus IDTB006 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (Sensus IDTB005 et Sensus IDTB006) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Integrated printed monopole with +2dBi
WARNING
e antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
EQG-10008-01