Sensus Metering Systems GFL Users Manual

Transmitter Certification
Test Report
FCC ID: SDBGFL
Subpart C
ACS Report Number: 06-0194-LD
Applicant: Advanced Metering Data Systems, LLC
Equipment Type: Water Meter Data Transmitter
Trade Name: Sensus AMDS GFL Gas Meter Transmitter
Model(s): GFL
Users Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Product Description
A significant advantage of the module is its powerful one- Watt transmitter. The long range enabled by the strong signal and high receiver sensitivity, minimizes the number of base station receivers an d provides optimal coverage at minimal deployment and ongoing costs. FlexNet transmitters are powered by a replaceable Lithium battery pack, with an expected service life of over 20 years.
The transmitter is enclosed in a durable polycarbonate casing with a clear cover that enables reusing the original meter index. The module consists of a narrow band transmitter, magnetic sensors, and mechanical meter interface that includes a shaft with a magnet. A handheld terminal is used to initialize operation. The module monitors the meter and sends data to the base station receiver network at predefined and programmable intervals. Transmitter messages contain meter reading data, status and relevan t parameters such as index pressure and the number of dials. Messages are routed to a database, where the data gets formatted for export to billing, marketing and customer service systems.
The FlexNet® wireless transmitter for gas AMR applications permits offsite meter reading by way of a fixed base radio network. In addition to solving meter reading problems such as lockouts, entering unsafe meter locations, "curbside" reading estimates, estimated billing, and errors associated with manual meter reading methods, a fixed network provides benefits such as daily reads and status alerts.
Sensus (Rockwell, Equimeter, Invensys)
American/Canadian Meter
Actaris (Sprague, Schlumberger)
RF Output Range
Modulation
Data Rate
Frequencies
Memory
30dBm (1 Watt) Urban area (typical) – over
5 miles (8 km)
Proprietary narrow band
Up to 8 Kbps 896-960 MHz, 10,240
channels x 6.25 kHz steps Non-volatile
Compatible Meters
R175, R200, RT200, RT230, R275, RT275, R315, R250, R310, S110, S200, 175S, S120, T120, T110 (11-tooth gear)
R415, RT100, RT360 (18-tooth gear) MR-8, MR-12 (16-tooth gear) W75AL, AL175, AC175, AT175, ALC175, AT210, AL225, 5B, AL250,
AR250, AC250, AT250, AM250, AL310, AL350, AT350, AL425, AC630 175, 175WC, 210, 240, 250, 250WC, METRIS 250, 400, 400A
(All slant interface, 3 hole index cover)
Specifications
Power Supply Battery Life
(Typical)
Lithium Thionyl Chloride batteries with HLC Over 20 years for daily reads Over 10 years for hourly reads FCC CFR 47 Part 15, Part 24,
Regulatory Compliance
Part 90, and Part 101 Rules Certified Intrinsic Safety Certification Measurement Canada Certification
Environmental
-40C to +80C, up to 95% relative humidity Magnetic tamper Non-reads,
Alerts
High/Low alerts – via MDM software
Warranty
20 years for battery (with daily reads) and electronics
1
Automated Meter Reading (AMR)
Meter Components
FlexNet 100G-FL
FlexNet 200G-FL
FlexNet 300G-FL
FlexNet 700G-FL
Transmitter Cover
Supported
Meters
AC250, AL175, AL250, AL5B (=AL225), AL425 and any other American Meter model with a standard residential index.
S175, S240, S250, Schlumberger Metris MET250 and S400, with slant index interface.
AC250, AL175, AL250, AL5B (=AL225), AL425 and any other American Meter model with a standard residential index.
Transmitter (on the left) is shown with cover and mounting plate
Sensus Sonix 12, 16, 25, volume correcting instruments and any other device with Form-A or ‘dry contact’ pulse output.