Sensus Metering Systems FLEXKV2C User Manual

SPECIFICATIONS

The kV2c meter with the FlexNet module will have a visible label containing the fol­lowing information:

Contains Model: FLEXKV2C

Contains FCC ID: SDBFLEXKV2C

Contains IC: 2220A-FLEXKV2C
QUICK GUIDE
FlexNet® SmartPoint® Module for Aclara kV2c
Quick Guide
The Sensus FlexNet™ SmartPoint® module provides wireless communication capability to electric utility meters. The Aclara kV2c commercial and industrial meter provides reliable and accurate revenue metering combined with advanced real-time instrumentation, true power quality monitoring and real cost of service measurements.
Technical Overview
The FlexNet communications network offers a simple, reliable, and secure system that is economical for mass meter deployments, strategic deployments, and rural applications while providing a multi-application solution for all AMI end points. The FlexNet network enhances the kV2c meter by providing AMI capability.
The FlexNet SmartPoint module is a printed circuit board which provides wireless communication capability to the Aclara kV2c electric meter. The SmartPoint module interrogates the meter registers on a programmable interval from five minutes to daily readings. The SmartPoint module then transmits the meter consumption and status information at regular intervals.
The module mounts into the existing kV2c meter and acts as a “third party AMR board.” It is designed to mount mechanically into the meter with no additional mechanical modification required.
The module communicates via the FlexNet fixed wireless telemetry network to provide electric meter readings and diagnostic data from the meter to the utility provider via radio.
The module contains both a receiver and transmitter to allow for two-way communications over the FlexNet network.
EQG-10010-01
FlexNet® SmartPoint® Module for Aclara kV2c
Warnings & Hazards
Warning
Sensus devices are for professional installation only. They are to be serviced by professional personnel only. This product is NOT for consumer installation or servicing.
Warning
The antenna used for this transmitter must not be co­located in conjunction with any other antenna or trans­mitter.
ATTENTION
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursu­ant to Part 15 of the FCC Rules. These limits are de­signed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encour­aged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different form that to which the receiver is connected
Consult the dealer or an experienced radio/TV tech­nician for help
RADIATION HAZARD
In order to satisfy the FCC RF exposure limit for transmit­ting devices, a separation distance of 20cm (7.9 inches) or more should be maintained while operating the Sensus FLEXKV2C. To ensure compliance, operation at closer than this distance is not recommended. This mini­mum safe distance is required between personnel and the antenna of this device.
RADIATION HAZARD
In order to satisfy the ISED RF exposure limit for trans­mitting devices, a separation distance of 20cm (7.9 inches) or more should be maintained while operating the Sensus FLEXKV2C. To ensure compliance, operation at closer than this distance is not recommended. This minimum safe distance is required between personnel and the antenna of this device.
An de satisfaire à la limite d’exposition RF pour les ap­pareils de transmission, une distance de séparation de 20cm (7.9 pouces) ou plus doit être maintenu pendant le fonctionnement du Sensus FLEXKV2C. Pour assurer
la conformité, un fonctionnement à distance inférieure à
celle est pas recommandée. Cette distance minimale de
sécurité est nécessaire entre le personnel et l’antenne de
cet appareil.
ATTENTION
Any modications made to this device that are not ap­proved by Sensus may void the authority granted to the user by the FCC to operate equipment.
Warning
If you are not sure of the rated power of your radio, contact your Sensus representative or dealer and supply the product model number found on the product label. If you cannot determine the rated power out, then assure 3-feet separation from the body to the device.
Warning
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO QUALIFIED SERVICE PER­SONNEL.
ATTENTION
This device complies with Industry Canada license­exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interfer­ence, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie
Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouil­lage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.