Operating manual Fx9x .
„GDB“ get energy - Energy value –0 to -120dB indicates the amount of receiving
energy
„GNR“ get serial number - „xxxxxxxxxx“ Serial no. is emitted as ASCII test
(max. 24 characters).
„GSI“ get error status - „DDDDDDD“
76543210
Output of error status, with D=“0“:
no error D=“1“:error:
D7: Transmitter faulty
D6: Receiver blinded or faulty
D5: Temperature warning:
T < -10°C or T > +70°C
D4: Target out of range or
transmitter faulty
D3: Temperature error: T > +85°C
D2: Supply voltage too low
D1: PLL unlocked
D0: always “0“
„GTE“ get temperature -
„±DDD“ DDD = internal temperature in °C
„GVE“ get version „Fx9x $Revision X.XX$“ Software version is sent
„GCM“ help command
/
get commands
- All available commands All available commands are sent in
text format
„ICM“ input continuous
mode
„0“ , „1“ ACK Measurement mode setting:
“0“ = continuous measurement
output, “1“ = output of single
measurement values
„IDO“ input offset -12000..+12000 or
-48000..+48000
ACK Setting offset in [mm] or
[INCH * 100]
„IH1“ input hysteresis Q1 „000“.. „254“
or
„000“..“999“ (INCH)
ACK Setting hysteresis around
switching points of Q1 in [mm] or
[INCH * 100]
„IH2“ input hysteresis „000“.. „254“
or
„000“..“999“ (INCH)
ACK Setting hysteresis around switching
points of Q2 in [mm] or [INCH *
100]
„IL1“ input limit
Q1 – 1
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK Setting the first switching point of
Q1 in [mm]
or [INCH*100]
„IL2“ input limit
Q2 – 1
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK Setting the first switching point of
Q2 in [mm]
or [INCH*100]
„IL3“ input limit
Q analog 1
Offset ...
+12000+Offset
ACK
Proximity switch only:
Setting 0% point of characteristic
analog curve
„IL4“ input limit
Q1 – 2
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK Setting second switching point of
Q1 in [mm]
or [INCH*100]
„IL5“ input limit
Q2 – 2
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK Setting second switching point of
Q2 in [mm]
or [INCH*100]
„IL6“ input limit
Q analog 2
Offset ...
+12000+Offset
ACK
Proximity switch only
Setting 100% point of characteristic
analog curve
„IM1“ input mode Q1 “0“, “1“, “2“ ACK “0“ = inactive, “1“= 1 switching
point,
“2“ = 2 switching points
„IM2“ input mode Q2 “0“, “1“, “2“ ACK “0“ = inactive, “1“= 1 switching
point,
“2“ = 2 switching points
„INA“ input norm
Q analog
“0“, “1“, ACK
Proximity switch only
“0“= Q, “1“=Q inverted
„IN1“ input norm Q1 “0“, “1“, ACK “0“= Q, „1“=Q inverted
„IN2“ input norm Q2 “0“, “1“, ACK “0“= Q, „1“=Q inverted
„IVL“ Input visible laser „0“ , „1“ ACK „0“=Pilotlaser off, „1“=Pilotlaser on
SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30 www.sensopart.de Page 11
Status 21.10.2004 Software 1.51 and higher 068-13621