Sensocar SC-A1 Complete User's Manual

SC-A1 Manual
User
SC-A1
Advanced weighing equipment with ABS or INOX finish, high contrast LED or backlit
LCD display and 5-key keyboard.
2017-02-14
COMPLETE USER MANUAL
- 2 -
- 3 -
Features
Weight-Tare-Piece counter with possibility of options and add-ons. Keys exclusively for the classic weighing system, similar to previous units, in the line of
SC1.
Clear, intelligible weighing symbols for improved, more convenient reading of the data
displayed. Printing of weight on the platform with large, notable size. Clock/Calendar fitted as standard. Quicker weighing system optimised for greater fluidity, accuracy and exactness. Intuitive menu system. Enter menu with fully configurable, flexible scale, fraction and decimals. Auto-calibration without having to re-adjust the weight when changing scales. On/off by key. Option to manually set the weight, for optimal, quick calibration. Piece counter function with more than a million internal points. Dedicated animal weighing function as standard. Smart display-repeater function, with possibility of repeating most market protocols. Extended accumulation: millions of accumulations with 64 bit totaliser. Standard manual tare. Accumulation and auto-accumulation of serial weighings. Automatic totalling of serial weighings. Accumulated Grand Total. Configurable number of lines to finish ticket and delays per printed line. Repeat ticket and optional ticket per weighing. Dedicated selectable connection to the most used printers. Label printing function (connection to Godex and Zebra labeller). Possibility of serial communications up to 115200 baud rate, N81, E71 and O71. Self-test of the default serial communication channels. Continuous programmable send time. Optional auto-zero in negative to prevent zero errors of the scales in hostile environments. Energy-saving and optimisation measures: low consumption mode and programmable
power-off due to inactivity. Transfer of external data and configuration from PC of the display parameters. Battery status indicator (in versions with battery). Possibility of independent auto-calibration of each display. Multirange totally programmable, flexible twin scales. Linearisation up to 16 points which can be easily defined by the user. Large selection of compatible printers with optional auto-cutter. Auto-calibration of analogue cell systems Customer-programmable password. 6 languages: Spanish, Portuguese, French, Italian, English and German.
- 4 -
INDEX
1 DISPLAY AND KEYBOARD DESCRIPTION ........................................................................... - 5 -
2 FUNCTIONS MENU .......................................................................................................... - 7 -
3 INSTRUCTIONS AND GENERAL OPERATION MODE ........................................................... - 9 -
3.1 Ordinary weighing (Net/gross tare, tare lock) .................................................................... - 10 -
3.1.1 Quick zero: ......................................................................................................................... - 11 -
3.1.2 Stability .............................................................................................................................. - 11 -
3.1.3 Quick tare .......................................................................................................................... - 12 -
3.1.4 Gross weight/net weight: .................................................................................................. - 13 -
3.1.5 Tare lock ............................................................................................................................ - 13 -
3.2 Manual tare....................................................................................................................... - 14 -
3.3 Extended accumulation and totalisation of weighings ........................................................ - 15 -
3.3.1 Manual accumulation ........................................................................................................ - 15 -
3.3.2 Automatic accumulation ................................................................................................... - 18 -
3.3.3 Totalise .............................................................................................................................. - 18 -
3.4 Piece counter .................................................................................................................... - 19 -
3.4.1 Accumulation and totalisation .......................................................................................... - 22 -
3.5 Units with Battery ............................................................................................................. - 23 -
3.6 Equipments with DSD memory (Aliby) ............................................................................... - 23 -
- 5 -
1 DISPLAY AND KEYBOARD DESCRIPTION
Stability Zero Tare Tare lock Gross
Piece
counter/Non-
metrological
Low
battery
ON / OFF:
On/Off (*)
T: Tare B: Zero/Gross FUN: Function INTRO:
Enter/Print
- 6 -
Environment Key Descriptions (standard functions)
Always ON/OFF
With the equipment power off, pressing the key turns the equipment on. With the equipment power on, long press the key (more than 2 seconds) turns the equipment off.
Entering data
of 3 figures
or less
T
Increase. Keeping it pressed down for a few seconds increases 10 by 10
when the lights
scroll is completed.
B
Decrease. Keeping it pressed down for a few seconds decreases 10 by 10 when t
he lights
scroll is completed.
FUN Leave.
INTRO Save and exit.
Entering
data
digit by
digit
T Increase digit.
B Change the digit to be modified (indicated by the corresponding decimal point).
FUN Leave.
INTRO Save and exit.
Weighing
T Carries out tare / tare lock / tare unlock.
B Zero is set. If there is a tare, the weight display mode is: net/gross.
FUN
Special key to combine with any of the others:
-T: Enter manual tare / relays menu (if active)
-B: Functions menu
-ENT: Totalise
If the Piece Counter option is active, pressing during scroll
will switch between
weight/pieces.
INTRO
The weighing is accumulated and printed
. If there is an active dosing programme, the
START/STOP function is carried out.
- 7 -
2 FUNCTIONS MENU
To enter: FUN+B
(The optional ones are shaded)
Option Description Actions
-
CODE
-
Code of weighing in progress.
(6 alphanumeric characters).
N.LABEL.
(**)
Label number.
T/B
to modify (0. .255 different labels). The 255 label is the total label. (It appears only when a labelling machine has been selected in the programming menu).
NOTE: See Programming Manual for more information.
TICKET
(***)
Delivery ticket/note number. (6 decimal digits).
If 0, it will not appear in the ticket. Otherwise it will increase automatically. (It does not appear in the equipments with DSD option)
TIK.REP.
Repeat ticket (0. .15 automatic tickets).
Up to 255 weighings. Each time a ticket is closed, proceed in accordance with the values:
-0: Normal operation (it does not repeat ticket).
-1: You will be asked whether to repeat the ticket.
-2. .15: There will be as many tickets as the value.
SUBTOT
Shows the accumulated weight subtotal so far.
INTRO
to show the total accumulated weights and the total weight. This will return to weighing state in a few seconds.
AUTOAC
Auto-accumulation when stability is reached.
Yes/No
AUT
.TAR
Auto Tare when stability is reached after passing through zero.
Yes/No
NU.ACUM
(*)
Number of accumulations before automatic totalling.
(0. .255 accumulations).
W.UNIQ.
(*)
Single weighing mode selection. Yes/No
There will be a complete ticket for each weighing (and also when totalising weighing).
BIG.TOT
Grand Total. Shows the accumulated weight total since the last time its value was reset.
INTRO
to show the accumulated grand total. INTRO during scroll: Prints and deletes the accumulated grand total. INTRO kept pressed during the scroll: Prints and erase the total accumulated.
F.WEIGHT
It displays the maximum weight. When pushing
[INTRO]
the memorized weight is erased and recalculates a new maximum.
Yes/No
HI-RES
High resolution. Shows the weight with another precision digit (Weight x 10)
INTRO for high resolution weighing. B makes a ZERO in the equipment.
PIECES
(*)
Advanced piece counter. Selects Piece counter mode
Yes/No When activated:
-FUN during scroll: Change pieces/weight.
DISCHA. (*)
Accumulation in download. Process (once in weight mode): 1- With full container press T. 2- Empty container and press INTRO. (repeat process until finishing with FUN + INTRO)
Yes/No
GROSS
(*)
Select ticket printing type GROSS­TARE-NET. (There will be a tare automatically after each accumulation)
Yes/No
P.ANIM. (
*)
Dynamic weighing for animals
INTRO
to access submenu.
FUN to exit submenu. T/B to navigate submenu.
--ON--
Yes/No Activate before editing the following values.
- 8 -
At high speed, it will be made an elevated number of weight samples with which the weight is calculated and the average is displayed at the end of the process.
LOW.BOW.
(6 digits). Inferior limit of weight:
-Weight values below this value are rejected. With AUTOMA=YES, waiting time T.INI is initiated when the weight exceeds this value.
HIG.BOW
(6 digits). Superior limit of weight:
- Weight values above this value are rejected.
INIT.T.
(0.. 25,5 seconds). With AUTOMA=YES. Waiting time before initiating the process of sample weight.
AWG.TIM
(0.. 25,5 seconds). Waiting time of the process of sample weight
AUTOMA
Yes/No: Yes -> Weight sample is automatically initiated once INIT.T. time is passed after the weight value defined in LOW.BOW is exceeded. No -> The equipment waits for the pressing of INTRO key to initiate the process of weight sample. (It does not wait for INIT.T. even though the LOW.BOW is exceeded).
IND.BAT.
Battery status indicator. (Only in units with battery)
INTRO
to see the battery status. If there is no battery: NOBAT If there is a battery: -OK- If there is low battery: -BATB-
CLOCK
Shows/Sets the clock and calendar.
INTRO to access submenu.
TIME
Displays the current time. (HH: MM: SS)
INTRO to edit:
T/B to modify (6 decimal digits). INTRO to save.
FUN to leave.
DATE
Displays the current date. (DD. MM. YY)
INTRO to edit:
T/B to modify (6 decimal digits). INTRO to save.
FUN to leave.
-
CELLS
-
Display points and weight of each load cell. (Only in equipments with communication cartridge for digital load cells)
INTRO
to access submenu.
FUN to exit submenu T/B to increase/decrease the number of load cell.
INTRO to select load cell.
CEL. xx
(load cell selection with T /B)
INTRO
to commute between points and weight.
T to select next load cell. FUN to exit and come back to load cell selection menu.
-DSD
- (*)
Consult and print data saved in DSD memory. (Only in equipments with DSD)
INTRO
to enter the Ticket / Delivery Note selection menu.
nnnnnn
Selection of ticket to consult (by default, it displays the number of the last ticket made)
T/B
to edit number of ticket (6 decimal digits). INTRO to select and initiate the visualization of number of weighings and the total accumulated weight from the selected ticket, or display EMPTY if there is no data.
(*) This option DOES NOT appear if there is an open ticket. (Close ticket by pressing FUN + T in Weight mode) (**) This option DOES NOT appear if any communication PORT of the equipment no has not been configured to connect to the labelling machine. (See option -COM- from Programming menu). (***) This option DOES NOT appear if the equipment has DSD. (With DSD option the equipment does not allow manual modification of the number of Ticket / Delivery Note)
- 9 -
3 INSTRUCTIONS AND GENERAL OPERATION MODE
When starting up the unit, the ON/OFF key can be pressed to carry out an initial test, showing all the display's digits and pilots.
The equipment identifier is then displayed:
Then, if the equipment has dead weight (units with weight module or digital cell communication), the counter value is shown the number of times the unit's metrological (weight) parameters have been modified.
Finally a message (banner type) describing the different functions of the unit is displayed.
- 10 -
Once complete, the unit again shows the measured weight (weight mode).
3.1 Ordinary weighing (Net/gross tare, tare lock)
By defect, the unit will start up showing the weight on the platform:
Both the text of the banner displayed when st
arting up the unit and the
headers and footers of the tickets can be defined by the user using the
SENSODATA program.
- 11 -
3.1.1 Quick zero:
Whenever, without any weight on the platform, the unit shows a weight value other than zero.
The zero should be manually corrected by pressing the B key.
3.1.2 Stability
The display shows the measured weight variations. The speed with which the changes and the degree of weight stability shown are displayed depend on the values set in the filter parameters. (Options STAB.T, FILTER and FIL.DEP in the Programming Menu).
As soon as the weight stabilises, the display activates the stability pilot ( ) to indicate the condition of stable weight.
The machine can automatically reset at start
-up
enabling
the
INIT.Z
option
in the WEI.OPT. programming submenu.
- 12 -
3.1.3 Quick tare
Pressing the T key when the unit shows stable weight other than zero causes the unit to tare the weight on the platform, making the weight value displayed on screen pass to 0 and activating the pilot NET.
As of this moment, the display shows the net weight whenever the platform weight changes. Whenever the net weight displayed is not zero, pressing the T key again causes the unit to
carry out a new Tare.
The Quick Tare function it’s only available when the number of divisions of
gross weight is bigger than the one defined in the minim weight option
(WEI.MIN) in the WE.CTR programming submenu.
Most of the actions carried out by the display (print ticket, start load or
discharge, etc.) are associated with stable platform condition.
Most of the actions carr
ied out by the display (tare, print ticket, start load
or discharge of dose, etc.) are associated with stable platform condition
(stable weight).
- 13 -
3.1.4 Gross weight/net weight:
With the unit tared, pressing the B key allows switching between net weight and gross weight on the display.
To indicate that the weight shown on the display corresponds to gross, enable both the B pilot and the NET pilot:
Tare is automatically disabled when all the weight is removed from the platform, deleting and re-displaying the gross weight:
3.1.5 Tare lock
To prevent tare from being disabled when all the weight is removed from the platform, press the T key a second time when the net weight shown is zero (pressing once tares the weight, and pressing twice locks tare).
Locking the tare activates the unit's >T< pilot in order to indicate locked tare. As of this moment, and always when the net weight shown is zero, the T key can switch between tare and tare locked modes.
- 14 -
3.2 Manual tare
The unit allows a tare value to be defined manually (*). To do this, press the FUN and T keys at the same time without leaving weight mode. The unit will enter manual tare edit mode, with the rightmost digit flashing to indicate the tare at this moment. To change the tare value displayed, use the T key to increase the flashing digit value, the B key to change digit, the FUN key to cancel and leave without validating, and the ENTER key to validate the tare value entered, taring the unit whilst locking the Tare.
When a manual tare is active, printing the tare on a ticket will be accompanied by the symbol "*", indicating that weighing was carried out with a manual tare.
(*)
The manual tare function is NOT available if the limit, traffic light or
any
dose option is enabled (options available through the APPLIC programming
submenu).
======================================== N.WEIGH. CODE TARE kg NET kg ======================================== 1 100350 * 21.57 0.216
T
The tare lock function is on
ly available if initial zero option (
INIT.Z
) has
been enabled in the WE.CTR programming submenu.
- 15 -
3.3 Extended accumulation and totalisation of weighings
The unit can account for weight (accumulate weighings), using the data to print a ticket per printer and/or label and/or send the weighing data through the serial communication ports (PORTS).
The unit allows individual weighings (printing a ticket for each weighing) or multiple weighings (with several weighings in the same ticket and finalised with a total) to be done automatically (when detecting stable weight on the platform) or manually (by pressing the INTRO key when the unit displays stable weight).
Three conditions must be met in order for the unit to account for a weight (carry out weighing): there must be stable weight, which exceeds the value defined as minimum weighing (*), with the weight dropping below the minimum weight necessary to carry out weighing at some point since last weighing (i.e. the last weighing has been discharged).
Pressing the key
3.3.1 Manual accumulation
In order to carry out manual accumulation, press the ENT key when the unit shows a stable weight value above the value defined as minimum weighing.
The following example assumes a stable weight of 1,754 kg, which we have previously tared manually at 1,538 kg. (1754-1538 = 0.216).
Single weighing is selected using the
W.UNIQ.
option in the Functions
menu.
Automatic weighing mode is selected using the AUTOAC option in the Functions menu.
(*) The minimum weight value for a weighing is determined using the WEI.MIN option in the unit's Programming menu.
- 16 -
Start manual weighing by pressing the ENT key to display the message:
The unit then briefly displays the number of weighings accumulated so far (in our case, the first):
And the accumulated weight subtotal (which, in our case, since it is the first weighing, coincides with the weighing made)
- 17 -
Once weighing is complete, the unit returns to weight mode and displays the weight on the platform.
If the unit is connected to a printer, and, for example, the code "100350" has been entered (using the -CODE- option in the functions menu), the following ticket will have been printed:
At the same time, if a PC connection has been configured in any of the serial communication PORTS with MANUAL send, pressing the T key causes a frame to be sent with the weight on the platform at this moment.
In order to carry out a new weighing and continue accumulating, remove the weight from the platform and place the new weight to accumulate on it; wait for the weight to be stable and then press the ENT key again.
======================================== N.WEIGH. CODE TARE kg NET kg ======================================== 1 100350 * 1.538 0.216
If the code
introduced
is 0 (default value when starting up the unit
), nothing
appears in the CODE field of the ticket.
All the unit's serial communication
PORTS can be configured (from the
-COM-programming submenu) to connect to a printer, a labeller, a repeater or a PC in order to send weights.
- 18 -
3.3.2 Automatic accumulation
Automatic accumulations do not require the INTRO key to be pressed for weighing; the unit simply has to detect a stable weight value greater than the value defined as minimum weighing (*) after the last weighing has been discharged.
3.3.3 Totalise
To complete and totalise all weighings in progress, keep the FUN and ENT keys pressed down at the same time. When doing this, the screen display switches between the total number of weighings made and the total weight accumulated, returning to weight mode by pressing any key.
For example, if 4 weighings are carried out with a total weight of 0.632 kg, the unit switches between the number of weighings
and the total accumulated weight
until any key is pressed and the unit returns to weight mode.
Automatic weighing mode is selected using the AUTOAC option in the
Functions menu.
(*) The minimum weight value for a weighing is determined using the
WEI.MIN option in the unit's WE.CTR. programming submenu.
- 19 -
If the unit is connected to a printer, the ticket will finish, as in the following example:
In this example, the following operations have been carried out in the ticket:
-Code 100350 has been entered.
-A container of 1.538 kg has been tared.
-A weight of 0.216 kg has been entered and accumulated.
- The weight and the container have been removed.
-A weight of 0.252 kg has been entered and accumulated.
-A weight of 0.083 kg has been entered and accumulated.
-A container of 0.252 kg has been tared.
-A weight of 0.081 kg has been entered and accumulated.
-Totalised by pressing FUN+ENT.
3.4 Piece counter
In piece counter mode the unit calculates and displays at all times the number of pieces resulting from dividing the measured weight and the weight of each piece.
Piece counter mode is enabled by entering the PIECES option in the unit's functions menu.
The unit can carry out and memorise up to
255 weighings before totalising, and
can accumulate a weight total of over 18 trillion weight units (g, kg, tn, lb) and a
Grand Total of over 60,000 weighings.
======================================== N.WEIGH. CODE TARE kg NET kg ======================================== 1 100350 1.538 0.216 2 100350 0.000 0.252 3 100350 0.000 0.083 4 100350 0.252 0.081 ======================================== TOTAL WEIGHINGS TOTAL WEIGHT kg ======================================== 4 0.632 ========================================
- 20 -
When leaving the functions menu, the unit returns to weight mode, displaying the measured weight.
From this moment on, the unit can switch between weight and piece counter modes by pressing the FUN key.
The unit enables the pilot to indicate that the value shown on screen corresponds to a number of pieces and not to a weight value.
A sample of the pieces to count is weighed in order for the unit to determine the unit weight value of each piece;
FUN
- 21 -
this is done by pressing the FUN key until the unit enters edit mode and the display flashes
0.
At this point the number of pieces corresponding to the weighed pieces sample is entered. To do this, use the T key to increase the value of the flashing digit, the B key to change digit, the FUN key to cancel editing and leave without saving, and the INTRO key to validate and save the piece value entered. The unit will very briefly display the calculated unit weight value.
It will then return to piece counter mode, displaying as of this moment the number of pieces corresponding to the weight measured in accordance with the unit weight calculated.
- 22 -
3.4.1 Accumulation and totalisation
Accumulation and totalisation in piece counter mode is carried out in the same way as in ordinary weighing: accumulate by pressing INTRO and totalise using FUN+INT. The ticket resulting from the operations with pieces has the following format:
This indicates the unit weight of the pieces, the weight and number of the pieces of each weighing and the total totalised pieces.
Switchi
ng between weight/pieces
(
pressing the
FUN
key
),
will cause the ticket to
close automatically.
======================================== P.Unit: 0.0013 ======================================== N.WEIGH. CODE NET kg PIECES ======================================== 1 0.251 195 2 0.123 95 ======================================== TOTAL WEIGHINGS PIECES ======================================== 2 290 ========================================
- 23 -
3.5 Units with Battery
Whenever the unit is battery-operated and this is below the correct threshold value, the corresponding LED will come on and the screen will show:
Automatically, the display illumination will be reduced to the minimum and configured to go off after 5 minutes of non-activity.
As a precaution, if low battery is detected when starting up, the display will not come on, showing first the aforementioned literals.
3.6 Equipments with DSD memory (Aliby)
DSD equipments with DSD memory record all weighings made in the equipment. This memory cannot be erased and it can store up to 500,000 weighings thanks to its capacity. In case the memory is fully occupied, the equipment rewrites the information of the oldest weighings so that the information relative to the latest 500,000 weighings can always be recovered.
The information of the memory is organized depending on the number of Ticket to which the weighing belongs to. Every ticket is made up with the weighings made from the Ticket opening until its finishing. In the equipments with DSD memory (Aliby), the number of Ticket is auto-increased with each new finalized ticket, not being able to be modified by the user. The -DSD- option from the functions menu allows consulting and printing a copy of each ticket made on the equipment. It displays the number of weighings, the total accumulated weight and the net weight of any of the ticket weighings. At the same time, it allows making a copy per printer of the ticket we are consulting. When accessing the -DSD- option from the functions menu, the equipment requests the number of ticket displaying by default the last finished ticket, for example:
- 24 -
This ticket number can be modified by pressing T key to increase the value of the flashing digit, B key to change digit, FUN key to abort and exit the option without validating, and INTRO key to validate the number displayed. Once the ticket number has been introduced, the equipment searches on the DSD memory the relative data to this ticket.
In case it does not find any associated weighing, the following message is displayed:
To exit right after and come back to -DSD- submenu
In case any associated weighing to the ticket is found, the equipment displays the “WAIT” message to indicate right after the number of weighings made on the ticket.
- 25 -
and the total accumulated weight.
By pressing T and B keys we will be able to move through the various weighings. First of all the number of weighing is displayed
and afterwards the recorded net weight:
- 26 -
While the total or various recorded values are displayed, by pressing INTRO key the printing of the ticket copy is initiated at the same time that the flashing message “Print” is displayed to indicate that a printing is being made.
Finally, FUN key exits the data visualization mode and enables to edit a new Ticket number.
- 27 -
*Electromagnetic susceptibility has been certified in tests conducted with field strength of 10 V/m, in accordance with new regulations.
Loading...