TeamConnect Ceiling 2
Instruction manual
Sennheiser electronic GmbH & Co. KG
Am Labor 1, 30900 Wedemark, Germany, www.sennheiser.com
Publ. 12/18
Inhaltsverzeichnis
Important safety instructions....................................................2
Intended use .............................................................. 2
Safety instructions for installation ............................................ 2
TeamConnect Ceiling 2 .........................................................2
Package contents ..............................................................3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Product overview ..............................................................3
Connectors and controls........................................................4
Connecting the SL Ceiling Mic 2 .................................................4
Connecting to the network
(power supply and configuration)............................................. 4
Outputting analog audio signals.............................................. 5
Outputting digital audio signals .............................................. 6
Planning the installation ........................................................7
Possible installation variants..................................................7
Adapting the installation height ...............................................7
Installing the SL Ceiling Mic 2 ...................................................8
Variant 1: installed flush in a dropped/coffered ceiling........................... 8
Variant 2: mounted directly below the ceiling...................................10
Variant 3: suspended from the ceiling .........................................11
Mounting the SL Ceiling Mic 2 on a VESA mount................................13
Configuring the TeamConnect Ceiling 2..........................................14
Downloading Sennheiser Control Cockpit......................................14
Configuring the TeamConnect Ceiling 2 with the Sennheiser Control Cockpit .......14
Configuring the TeamConnect Ceiling 2 with a media control system ..............15
Specifications ................................................................16
TeamConnect Ceiling 2 | 1
Important safety instructions
Important safety instructions
1. Read these safety instructions and the instruction manual of the product.
2. Keep these safety instructions and the instruction manual of the product. Always include all instructions when
passing the product on to third parties.
3. Always include this instruction manual and the safety guide when passing the product on to third parties.
4. Only use attachments, accessories and spare parts specified by the manufacturer.
5. Do not attempt to open the product housing on your own. The warranty is voided for products opened by the customer.
6. Refer all servicing to qualified service personnel. Servicing is required when the product has been damaged in any
way, liquid has been spilled or objects have fallen into the product, when the product has been exposed to rain or
moisture, does not operate normally, or has been dropped.
7. Use the product only under the conditions of use listed in the specifications.
8. Do not operate the product if it was damaged during transportation.
9. Always run cables so that no one can trip over them.
10. Keep the product and its connections away from liquids and electrically conductive objects that are not necessary for
operating the product.
11. Do not use any solvents or aggressive cleaning agents to clean the product.
12. Caution: Very high signal levels can damage your hearing and your loudspeakers. Reduce the volume on the connected
audio devices before switching on the product; this will also help prevent acoustic feedback.
Intended use
The product is designed for indoor use, such as in conference rooms or presentation halls.
The product can be used for commercial purposes.
It is considered improper use when the product is used for any application not named in the corresponding instruction
manual.
Sennheiser does not accept liability for damage arising from improper use or misuse of this product and its attachments/
accessories.
Before putting the products into operation, please observe the respective country-specific regulations!
Safety instructions for installation
Observe the following safety instructions when installing the product.
The physical mounting and all electrical installations must be performed by a specialist.
The specialist must have sufficient professional training, experience and knowledge of applicable provisions,
regulations and standards to be able to properly assess the work assigned to them, identify possible hazards and take
appropriate safety measures.
When mounting the product, observe and follow all local, national and international regulations and standards.
TeamConnect Ceiling 2
The TeamConnect Ceiling 2 consists of the SL Ceiling Mic 2 and the Sennheiser Control Cockpit configuration software.
This manual contains all the information you need to install and mount the ceiling microphone as well as instructions for
configuring the product using the Sennheiser Control Cockpit.
This instruction manual is available in other languages on the Sennheiser website:
www.sennheiser.com/tcc2
2 | TeamConnect Ceiling 2
Package contents
• SL Ceiling Mic 2
• 3-pin Phoenix connector (3.81)
• 8 self-adhesive rubber feet
• Instruction manual
• Supplement sheet with manufacturer declarations
Accessories
Package contents
SL CM FB
Ceiling mounting frame
M4x8
M4x126.4 mm
Art. no. 506846
SL CM SK
Ceiling suspension set
M3x6
Art. no. 508291
Product overview
SL CM EB US
Angle brackets
(for 2 ft ceiling grid)
Art. no. 508528
SL CM VB
VESA adapter
M6x16
Art. no. 508620
SL CM EB 625
Angle brackets
(for 625 mm ceiling grid)
Art. no. 508290
Bottom Top
1
1 Status LEDs Multi-colored, can be configured with software
2 Microphone capsules 28 x KE 10-237
3 Connection sockets See next page
1
2
11
3
TeamConnect Ceiling 2 | 3
Connectors and controls
Connectors and controls
Primary ResetSecondary
4 5 6 7
Analog Out
+ -
Ethernet
PoE/Ctrl
4 Digital audio output Dante™ interface with two RJ-45 sockets, Primary and Secondary
• Supports redundancy and switched mode
5 Reset button To restore the factory settings
• Hold for 5 seconds
6 Analog audio output 3-pin socket
• Suitable for Phoenix Contact MCVW 1.5-3-ST-3.81
7 PoE/Ctrl socket RJ-45 socket
• PoE supply (Power over Ethernet)
• Configuration via the software or a media control system
Connecting the SL Ceiling Mic 2
Connecting to the network
(power supply and configuration)
The Ethernet PoE/Ctrl RJ-45 socket is used to both power the SL Ceiling Mic 2 via Power over Ethernet and configure it
using the Sennheiser Control Cockpit software (see „Configuring the TeamConnect Ceiling 2“ on page 14).
In your network you can either use a switch that provides PoE or a PoE injector.
Use only shielded STP network cables that do not exceed an AWG value of 24.
SL Ceiling Mic 2
-
LAN
LAN
optional
Optional
PoE
LAN oder WiFi
LAN or WiFi
Control Cockpit Host PC
Control Cockpit host PC
(opt.Client)
(opt. client)
Media Control Client
Media control client
Media Control Server
Media control server
4 | TeamConnect Ceiling 2
optional
Optional
LAN or WiFi
LAN oder WiFi
Control Cockpit Clients
Control Cockpit clients