user name: admin
password: ******
new password:
1: Administrator Login
2: Configure Regulatory Domain
3: Configure Access Point
ConnectStation CS1-C
CinemaConnect
AC Power
supply
Briefly press
the button
< 1s on
Quick Guide
2 Connecting audio devices 1 Connecting the product to the mains
1 AUDIO BREAKOUT
1 2 3
4
4 Connecting the access point3 Switching the product ON
Zoneflex 7372
access point
The ConnectStation provides DHCP
Power supply
access point
service to the access point and clients.
Connect the access point directly
to the ConnectStation.
2x RCA unbalanced
2 ADAT/SPDIF
Toslink input
8 channels, 24 bit
3 SPDIF/AES
1x RCA
4 ANALOG IN
4x 1/4" (6.3 mm)
TRS jack
servo balanced
boot up
orange
5.1 Connecting a laptop
LAN cable to
5.3 Logging in to the system
system running
green green
Enter user name and
password for login.
5.2 Configuring the laptop
Configure the laptop with the
static IP address 192.168.0.2
Open your browser and
navigate to: 192.168.0.10
5.4 Performing the initial setup
Follow the instructions in the Web
Interface to perform the initial setup
of your ConnectStation.
Default user name: “admin”
password: “sennheiser”
The configuration ist done. The system is ready to connect to a mobile
device containing the CinemaConnect App.
ConnectStation CS1-C
CinemaConnect
Specifications
Dimensions W x D x H
Weight
Power supply
Power
Operating temperature
Storage temperature
Operating humidity
Storage humidity
AUDIO BREAKOUT
Input
Input impedance
Input sensitivity
Resolution AD
Frequency response AD
@ 44.1 kHz, -0.5 dB
ADAT/SPDIF
Input
Standard
Lock range
SPDIF/AES
Input
SPDIF compatible
Impedance
Lock range
ANALOG IN
Input
Input impedance
Input sensitivity
Resolution AD
Frequency response AD
@ 44.1 kHz, -0.5 dB
Sample rate
For more detailed specifications please refer to the product
specification sheet in the download area of the product page
at www.sennheiser-connect.com.
48.3 cm x 24.0 cm x 4.4 cm
(19.0" x 9.5" x 1.7")
2.9 kg (6.39 lbs)
100 - 240 V AC, 50/60 Hz,
max. 600 mA
60 W nominal
+5 °C to +45 °C (41°F to 113 °F)
-20 °C to +75 °C (-4°F to 167 °F)
10 % to 90 % @ 25 °C non-condensing
5 % to 95 % @ 25 °C non-condensing
2x RCA unbalanced
10 kΩ
Low gain, +4 dBu, -10 dBV
24 bit
5 Hz to 21.5 kHz
TOSLINK
8 channels, 24 bit, up to 48 kHz
31.5 to 50 kHz
1x RCA
IEC 60958
75 Ω
27 to 200 kHz
4x 1/4" (6.3 mm) TRS jack,
servo balanced
10 kΩ
Low gain, +4 dBu, -10 dBV
24 bit
5 Hz to 21.5 kHz
48 kHz
6 Switching the product OFF
Briefly press
the button
shut down
orange
< 1s off
system off
Delivery includes
1x ConnectStation CS1-C
1x Power Supply Cable 1.8 m (EU/UK/US)
1x Ruckus ZoneFlex 7372 Access Point (worldwide/US)
1x Ruckus Power Supply Adapter for Access Point (EU/UK/US)
INPUT: 100 – 240 V AC, 50/60 Hz, 0.4 A
OUTPUT: 12 V DC, 1.0 A
Audio Cables
1x 15-pin D-sub to 4 x RCA Analog, 2 x MIDI, 1 x Phones
1x 9-pin D-sub to 2 x RCA Digital (SPDIF)
1x Toslink Cable 2 mm, 2m
Specifications
List of Audio Channels
Analog In 4 Channels
SPDIF
Analog I/O 2 Channels
ADAT Input
ADAT Output
Active
Active
Active
Active
N.A.
Quick Guide
Safety Guide
DE
EN
FR
IT
ES
NL
SV
Checking for errors – Troubleshooting
Warning
Alert: Fatal error
orange orange
Sennheiser electronic GmbH & Co. KG
Am Labor 1, 30900 Wedemark, Germany
www.sennheiser.com
Publ. 06/15, 560070/A02
red
DHCP enabled,
ports 1194 +1195,
UDP open
Sennheiser Service:
Please send an email with the serial number of the ConnectStation CS1-C to
service@sennheiser-connect.com for remote service .
For monitoring and remote diagnostics connect the device to the internet.