Safety instructions for the Lithium-Ion battery pack
A detailed instruction manual for the overall ADN conference system can
www
www.sennheiser.com
Manual
be found
•on the Internet at www.sennheiser.com or
•on the DVD-ROM supplied with the ADN CU1 central unit.
Safety instructions for the Lithium-Ion
battery
If abused or misused, the ADN-W BA battery pack may leak. In extreme
cases, it may even present
Please understand that Sennheiser does not accept liability for damage
arising from abuse or misuse.
pack
•a heat hazard,
•a fire hazard,
Keep away from
children.
Observe correct
polarity.
Do not expose to
moisture.
Only charge the
battery pack with
the appropriate
Sennheiser chargers.
Only charge the
battery pack at ambi
ent temperatures
between 10°C/50°F
and 45°C/113°F.
Immediately remove
the battery pack from
an obviously defec
tive device.
-
•an explosion hazard,
•a smoke or gas hazard.
Do not pack charged battery
packs loose.
Do not short-circuit.
Do not mutilate or dismantle.
When not using the battery
pack for extended periods
of time, charge it regularly
(charge it to approx. 50%
of capacity about every
3 months).
Do not heat above 45°C/
-
113°F, e.g. do not expose to
sunlight or throw into a fire.
Do not continue to use a
defective battery pack.
ADN-W BA | 1
The ADN-W BA Lithium-Ion battery pack
Switch battery packpowered devices off
after use.
Only use the original
Sennheiser battery
packs.
Intended use
Intended use of the product includes
•using the product for professional purposes,
•having read and understood this instruction manual, especially the
chapter “Safety instructions for the Lithium-Ion battery pack” on
page 1,
•using the product within the operating conditions and limitations
described in this instruction manual.
“Improper use” means using the product other than as described in this
instruction manual, or under operating conditions which differ from
those described herein.
When not using the device
for extended periods of time,
remove the battery pack
from the device.
Dispose of the battery pack
at special collection points or
return it to your specialist
dealer.
The ADN-W BA Lithium-Ion battery pack
The ADN-W BA Lithium-Ion battery pack is part of the Sennheiser ADN
conference system.
The ADN-W BA battery pack is designed for powering the ADN-W C1 and
ADN-W D1 wireless conference units. It offers an operating time of
approx. 20 hours.
2 | ADN-W BA
Package contents
1 ADN-W BA Lithium-Ion battery pack
1 instruction manual
To charge the ADN-W BA battery pack, you additionally require
the ADN-W
power supply.
L 10 or ADN-W CASE UNITS chargers or the NT 12-50C
Hollow jack socket for
connection of NT 12-50C
power supply
Button for charge status
indication
Charge status indicator
Contacts for connection to
wireless conference unit and
ADN-W L 10 charger
Battery release clip
Type plate
ADN-W BA | 3
Inserting/removing the ADN-W BA
1
2
1
2
12345
5
6
6
5
6
B
8
Over view of the status LEDs
Status LEDsColorMeaning
Battery status
indicator
RF status
indicator
The charge status display consists of 5 LEDs and can be called up by
pressing the button . During charging, the LEDs show the obtained
capacity.
LED ColorRemaining capacity Remaining operating time
1redapprox. 0 - 19 % approx. 0 - 4 hours
2orange approx. 20 - 39 % approx. 4 - 8 hours
3orange approx. 40 - 59 % approx. 8 - 12 hours
4greenapprox. 60 -79 % approx. 12 - 16 hours
5greenapprox. 80 - 100 %approx. 16 - 20 hours
–Battery capacity 5-100%
orange, flashing slowly Battery capacity < 5%,
battery pack is almost flat
orange, flashing rapidly Battery pack is defective
–Good transmission quality
blue, flashing slowlyTransmission quality is
temporarily reduced
blue, flashing rapidlyTransmission quality is
permanently reduced
4 | ADN-W BA
Inserting/removing the ADN-W BA
To insert theADN-W BA battery pack into the wireless conference unit:
왘 Check the battery pack before using it in order to ensure sufficient
battery capacity and to exclude a defective battery pack (see
8).
page
왘 Charge the battery pack if necessary (see page 5).
왘 Slide the battery pack into the battery guide rails of the wireless
conference unit.
The battery release clip locks into place with an audible click and
secures the battery pack.
Charging the ADN-W BA
8
4
NT 12-50C
EU
UK
US
4
To remove the battery pack from the wireless conference unit:
왘 Press the battery release clip and pull the battery pack out of the
battery guide rails.
C
8
8
Charging the ADN-W BA
The ADN-W BA battery pack can be charged:
•while it is inserted in the wireless conference unit using the
12-50C power supply – even during operation,
NT
•separately using the NT 12-50C power supply,
•separately in the ADN-W L 10 charger,
•while it is inserted in the wireless conference unit using the
ADN-W CASE UNITS charging case
왘 Connect the NT 12-50C power supply to the hollow jack socket or
charge the battery pack using the ADN-W L 10 or ADN-W CASE UNITS
charger (see the instruction manual of the charger).
ADN-W BA | 5
Charging the ADN-W BA
For optimum performance, durability and maintenance of the
ADN-W BA battery pack, please observe the following:
•You can immediately use the ADN-W BA battery pack (bat-
tery capacity of approx. 30 % upon delivery). You only have to
recharge the battery pack when the battery charge is low. An
initialization charge is not necessary.
•You can charge the battery pack at any time and for as
long as you want. A complete charge cycle (100 %) is not
necessary.
•You do not have to regularly deep-discharge the battery pack
to reach an optimum battery life cycle.
•If the displayed remaining operating time of the battery pack
significantly differs from the actual operating time, you can
re-calibrate the operating time display. To do so, completely
discharge the battery pack and then fully recharge it again
(100%).
•After charging, the battery pack can remain in the charger.
The intelligent charging electronics monitors the charging
process and prevents incorrect battery charging.
•When not using the wireless conference unit for extended
periods of time, remove the battery pack from the device.
Cover the contacts to avoid short circuits.
•When storing the battery pack for extended periods of time,
charge it to approx. 50% of capacity.
•Only store the battery pack within the specified storage tem-
perature range (see page 9).
6 | ADN-W BA
Charging the ADN-W BA
1
6
1
6
6
1
Behavior of the ADN-W BA battery pack during charging
When charging the battery pack usingthe NT 12-50C power supply or the
ADN-W L10 or ADN-W CASE UNITS chargers, the battery pack and the
corresponding charger will get warm. The battery status indicator
the charge status display indicate the charging process:
Battery status indicator Charge status displayMeaning
lights up orangelights up (the current
charge status flashes)
offoff
orange, flashing rapidly–
Battery pack is
being charged,
a complete
charging pro
cess takes
approx. 4 hours
Battery pack is
fully charged,
continuous
capacity
monitoring
Battery pack is
defective
and
-
1
Charging may take longer if the temperature of the battery pack is below
10°C or over 45°C. In this case, in order to protect the battery pack, the
charging process is interrupted until the temperature is again within the
admissible range and the battery status indicator
The charging process starts automatically.
lights up orange.
ADN-W BA | 7
Charging the ADN-W BA
5
6
1
1
5
6
12345
Checking the charge status of the battery pack
왘 Press the button .
The charge status display shows the current battery capacity for
approx. 5 seconds. During operation, the battery status indicator
also indicates when the battery pack is almost flat (see table on
page 4).
8 | ADN-W BA
Specifications ADN-W BA
Specifications ADN-W BA
Nominal output voltage
Capacity
Charging voltage
Charging current
Charging time
Temperature rangeoperation: +10°C to +45°C
Relative humidityoperation: 20 to 95%
Dimensions (W x H x D)approx. 143 x 27 x 124 mm
Weightapprox. 404 g
In compliance with
EuropeEMCEN 301489-1/-17
USAUL 1642Standard for
UN transportation testaccording to
7.4 V
7800 mAh
12 V
2.5 A
with a completely discharged battery
pack and at room temperature:
approx. 100% = typ. 4 hours
storage: –25°C to +70°C
Charging: +10 °C to +45 °C
storage: 10 to 90%
SafetyIEC/EN 62133
Lithium Batteries
UL 2054Standard for Household and
Commercial Batteries
UN Manual of Tests and Criteria, Part III,
section 38.3 Lithium-Ion batteries
Certified by
USA/Canada
Japan
ADN-W BA | 9
Manufacturer Declarations
Manufacturer Declarations
Warranty
Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on
this product.
For the current warranty conditions, please visit our website at
www.sennheiser.com or contact your Sennheiser partner.
In compliance with the following requirements
•Battery Direc
The supplied rechargeable batteries or batteries can be recycled.
Please dispose of them as special waste or return them to your
spe-cialist dealer. In order to protect the environment, only
dispose of exhausted batteries.
•China RoHS Directive
CE Declaration of Conformity
•EMC Directive
•RoHS Directive (2011/65/EU)
tive (2013/56/EU)
(2014/30/EU)
10 | ADN-W BA
The declarati
Before putting the product into operation, please observe the respective