Sennheiser Adn-w BA User Manual

ADN-W BA
Li-Ion Battery Pack
Instruction manual

Safety instructions for the Lithium-Ion battery pack

A detailed instruction manual for the overall ADN conference system can
www
www.sennheiser.com
Manual
on the Internet at www.sennheiser.com or
on the DVD-ROM supplied with the ADN CU1 central unit.
Safety instructions for the Lithium-Ion battery
If abused or misused, the ADN-W BA battery pack may leak. In extreme cases, it may even present
Please understand that Sennheiser does not accept liability for damage arising from abuse or misuse.
pack
a heat hazard,
a fire hazard,
Keep away from children.
Observe correct polarity.
Do not expose to moisture.
Only charge the battery pack with the appropriate Sennheiser chargers.
Only charge the battery pack at ambi ent temperatures between 10°C/50°F and 45°C/113°F.
Immediately remove the battery pack from an obviously defec tive device.
-
•an explosion hazard,
•a smoke or gas hazard.
Do not pack charged battery packs loose.
Do not short-circuit.
Do not mutilate or dismantle.
When not using the battery pack for extended periods of time, charge it regularly (charge it to approx. 50% of capacity about every 3 months).
Do not heat above 45°C/
-
113°F, e.g. do not expose to sunlight or throw into a fire.
Do not continue to use a defective battery pack.
ADN-W BA | 1

The ADN-W BA Lithium-Ion battery pack

Switch battery pack­powered devices off after use.
Only use the original Sennheiser battery packs.

Intended use

Intended use of the product includes
using the product for professional purposes,
having read and understood this instruction manual, especially the chapter “Safety instructions for the Lithium-Ion battery pack” on page 1,
using the product within the operating conditions and limitations described in this instruction manual.
“Improper use” means using the product other than as described in this instruction manual, or under operating conditions which differ from those described herein.
When not using the device for extended periods of time, remove the battery pack from the device.
Dispose of the battery pack at special collection points or return it to your specialist dealer.
The ADN-W BA Lithium-Ion battery pack
The ADN-W BA Lithium-Ion battery pack is part of the Sennheiser ADN conference system.
The ADN-W BA battery pack is designed for powering the ADN-W C1 and ADN-W D1 wireless conference units. It offers an operating time of approx. 20 hours.
2 | ADN-W BA

Package contents

1 ADN-W BA Lithium-Ion battery pack
1 instruction manual
To charge the ADN-W BA battery pack, you additionally require the ADN-W power supply.
L 10 or ADN-W CASE UNITS chargers or the NT 12-50C

Product overview ADN-W BA

1
2
3
4
8
7
7
5
6
9
5
Rechargeable Lithium-Ion Battery Pack
Art.No.: 504744 Ser.-No.:
MADE IN POLAND
Rated Voltage/Capacity/Energy: 7.4V/7.8Ah/57.72Wh Charge Voltage/Current: 12V/2.5A 2ICR19/65-3
ADN-W BA
LI-ION
LISTED
CUS
1
2
3
4
5
6
789
Product overview ADN-W BA
Battery status indicator
RF status indicator
Charging contacts for ADN-W CASE UNITS charging
case
Hollow jack socket for connection of NT 12-50C power supply
Button for charge status indication
Charge status indicator
Contacts for connection to wireless conference unit and ADN-W L 10 charger
Battery release clip
Type plate
ADN-W BA | 3

Inserting/removing the ADN-W BA

1
2
1
2
12345
5
6
6
5
6
B
8

Over view of the status LEDs

Status LEDs Color Meaning
Battery status indicator
RF status indicator
The charge status display consists of 5 LEDs and can be called up by pressing the button . During charging, the LEDs show the obtained capacity.
LED Color Remaining capacity Remaining operating time
1 red approx. 0 - 19 % approx. 0 - 4 hours
2 orange approx. 20 - 39 % approx. 4 - 8 hours
3 orange approx. 40 - 59 % approx. 8 - 12 hours
4 green approx. 60 -79 % approx. 12 - 16 hours
5 green approx. 80 - 100 % approx. 16 - 20 hours
Battery capacity 5-100%
orange, flashing slowly Battery capacity < 5%,
battery pack is almost flat
orange, flashing rapidly Battery pack is defective
Good transmission quality
blue, flashing slowly Transmission quality is
temporarily reduced
blue, flashing rapidly Transmission quality is
permanently reduced
4 | ADN-W BA
Inserting/removing the ADN-W BA
To insert the ADN-W BA battery pack into the wireless conference unit:
Check the battery pack before using it in order to ensure sufficient
battery capacity and to exclude a defective battery pack (see
8).
page
Charge the battery pack if necessary (see page 5).
Slide the battery pack into the battery guide rails of the wireless
conference unit. The battery release clip locks into place with an audible click and secures the battery pack.

Charging the ADN-W BA

8
4
NT 12-50C
EU UK US
4
To remove the battery pack from the wireless conference unit:
Press the battery release clip and pull the battery pack out of the
battery guide rails.
C
8
8
Charging the ADN-W BA
The ADN-W BA battery pack can be charged:
while it is inserted in the wireless conference unit using the 12-50C power supply – even during operation,
NT
separately using the NT 12-50C power supply,
separately in the ADN-W L 10 charger,
while it is inserted in the wireless conference unit using the
ADN-W CASE UNITS charging case
Connect the NT 12-50C power supply to the hollow jack socket or
charge the battery pack using the ADN-W L 10 or ADN-W CASE UNITS charger (see the instruction manual of the charger).
ADN-W BA | 5
Charging the ADN-W BA
For optimum performance, durability and maintenance of the ADN-W BA battery pack, please observe the following:
You can immediately use the ADN-W BA battery pack (bat-
tery capacity of approx. 30 % upon delivery). You only have to recharge the battery pack when the battery charge is low. An initialization charge is not necessary.
You can charge the battery pack at any time and for as
long as you want. A complete charge cycle (100 %) is not necessary.
You do not have to regularly deep-discharge the battery pack
to reach an optimum battery life cycle.
If the displayed remaining operating time of the battery pack
significantly differs from the actual operating time, you can re-calibrate the operating time display. To do so, completely discharge the battery pack and then fully recharge it again (100%).
After charging, the battery pack can remain in the charger.
The intelligent charging electronics monitors the charging process and prevents incorrect battery charging.
When not using the wireless conference unit for extended
periods of time, remove the battery pack from the device. Cover the contacts to avoid short circuits.
When storing the battery pack for extended periods of time,
charge it to approx. 50% of capacity.
Only store the battery pack within the specified storage tem-
perature range (see page 9).
6 | ADN-W BA
Charging the ADN-W BA
1
6
1
6
6
1

Behavior of the ADN-W BA battery pack during charging

When charging the battery pack usingthe NT 12-50C power supply or the ADN-W L10 or ADN-W CASE UNITS chargers, the battery pack and the corresponding charger will get warm. The battery status indicator the charge status display indicate the charging process:
Battery status indicator Charge status display Meaning
lights up orange lights up (the current
charge status flashes)
off off
orange, flashing rapidly
Battery pack is being charged, a complete charging pro cess takes approx. 4 hours
Battery pack is fully charged, continuous capacity monitoring
Battery pack is defective
and
-
1
Charging may take longer if the temperature of the battery pack is below 10°C or over 45°C. In this case, in order to protect the battery pack, the charging process is interrupted until the temperature is again within the admissible range and the battery status indicator The charging process starts automatically.
lights up orange.
ADN-W BA | 7
Charging the ADN-W BA
5
6
1
1
5
6
12345

Checking the charge status of the battery pack

Press the button .
The charge status display shows the current battery capacity for approx. 5 seconds. During operation, the battery status indicator also indicates when the battery pack is almost flat (see table on page 4).
8 | ADN-W BA

Specifications ADN-W BA

Specifications ADN-W BA
Nominal output voltage
Capacity
Charging voltage
Charging current
Charging time
Temperature range operation: +10°C to +45°C
Relative humidity operation: 20 to 95%
Dimensions (W x H x D) approx. 143 x 27 x 124 mm
Weight approx. 404 g

In compliance with

Europe EMC EN 301489-1/-17
USA UL 1642 Standard for
UN transportation test according to
7.4 V
7800 mAh
12 V
2.5 A
with a completely discharged battery pack and at room temperature:
approx. 100% = typ. 4 hours
storage: –25°C to +70°C Charging: +10 °C to +45 °C
storage: 10 to 90%
Safety IEC/EN 62133
Lithium Batteries
UL 2054 Standard for Household and
Commercial Batteries
UN Manual of Tests and Criteria, Part III, section 38.3 Lithium-Ion batteries

Certified by

USA/Canada
Japan
ADN-W BA | 9

Manufacturer Declarations

Manufacturer Declarations

Warranty

Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this product.
For the current warranty conditions, please visit our website at www.sennheiser.com or contact your Sennheiser partner.

In compliance with the following requirements

Battery Direc The supplied rechargeable batteries or batteries can be recycled. Please dispose of them as special waste or return them to your spe-cialist dealer. In order to protect the environment, only dispose of exhausted batteries.
China RoHS Directive

CE Declaration of Conformity

EMC Directive
RoHS Directive (2011/65/EU)
tive (2013/56/EU)
(2014/30/EU)
10 | ADN-W BA
The declarati
Before putting the product into operation, please observe the respective country-specific regulations.
on is available at www.sennheiser.com/download
Sennheiser electronic GmbH & Co. KSennheiser electronic GmbH & Co. KGG
Am Labor 1, 30900 Wedemark, Germany www.sennheiser.com
Printed in Germany, Publ. 08/16, 549137/A03
Loading...