Please make sure to read the “Safety information” supplement included separately
with the product. This supplement contains important information on the safe
operation of the product as well as the manufacturer’s declaration and warranty
notes.
A detailed instruction manual for the overall ADN conference system can be found
•on the Internet at www.sennheiser.com or
•on the DVD-ROM supplied with the ADN CU1 central unit.
The ADN CU1 central unit
The ADN CU1 central unit is part of the Sennheiser ADN conference system.
The central unit controls the operation of the entire conference system. Up to max.
40 ADN D1 delegate units and ADN C1 chairperson units can be directly connected
to the central unit. For larger conference systems with up to max. 400 conference
units, the central unit can also manage up to 15 ADN PS power supplies.
For configuring the conference system, you can either use the central unit’s operating menu or the “Conference Manager” software.
Conferences
with up to a max. of
40 participants
ADN CU1
• REC
Conferences with up to a max. of 400 participants
“Conference Manager”
ADN PSADN PS
software
max. 15 ADN PS
max. 400 ADN D1/
ADN C1
2 | ADN CU1
max. 40
ADN D1/ADN C1
per ADN PS with
standard cabling a
max.of 70 ADN D1/ADN C1
per ADN PS with
redundant ring cabling a
max. of 40 ADN D1/ADN C1
Delivery includes
Delivery includes
1 ADN CU1 central unit
1 mains cable (EU, UK or US version), length 1.8 m
1 quick guide
1 “Safety information” supplement
1 including, among other things, the “Conference Manager” software, the
“ADN Cable Calculator” software and the instruction manual for the overall
conference system as PDF
Components required for operation
Central unit/
Power supplies
Conference units
System cablesThe system cables are black and have two shielded RJ45 modular plugs.
Number DescriptionCat. No. Function
1ADN CU1-EU central unit,
EU version
ADN CU1-UK central unit,
UK version
ADN CU1-US central unit,
US version
1 – 15
(optional)
Number DescriptionCat. No. Function
Max. 400ADN D1 delegate unit502758 Allows to make contributions
1 – 10
(optional)
ADN PS-EU power supply,
EU version
ADN PS-UK power supply,
UK version
ADN PS-US power supply,
US version
ADN C1 chairperson unit502759 Allows to manage the
505553 Controls the conference and
supplies power to max. of
505554
505555
505546 Supplies power to conference
505547
505548
40 conference units
units connected in simple
strings or in redundant ring
topology,
for conferences with up to
400 conference units
to the conference
conference
Number Description, lengthCat. No. Function
DiversSDC CBL RJ45-2, 2 m009842 Allow to interconnect
SDC CBL RJ45-3, 3 m009843
SDC CBL RJ45-5, 5 m 009844
SDC CBL RJ45-10, 10 m 009845
SDC CBL RJ45-20, 20 m 009846
SDC CBL RJ45-50, 50 m 009847
Additional accessories for the ADN conference system can be found at
www.sennheiser.com.
components and conference
units
ADN CU1 | 3
Product overview ADN CU1 central unit
Product overview
ADN CU1 central unit
1
IN –– AUDIO –– OUT
PORT II PORT I
2x 52.8V 1.75A
678 9@A B
2345
ESC
C
E
F
15
100-240V~
50/60Hz 240W
D
A Front view
1 On/off switch
2 Standard display key
3 Display panel
4 Jog dial
5 ESC key (Escape)
B Rear view
6 IN audio input
7 OUT audio output
8 PORT II socket (RJ 45) for connection
of conference units
9 PORT I socket (RJ 45) for connection
of conference units
0 VGA monitor output
A USB socket (2x)
B Network socket (RJ 45)
C Fans
D Mains socket
E Hazard warnings
F Type plate
4 | ADN CU1
Product overview ADN CU1 central unit
Direct Access
30 Units
22
G
M
N
O
P
H
I
L
J
K
GHI
JKLMNOP
Overview of the ADN CU1 display panel
After switch-on, the central unit’s display shows progress bars (for the booting
routine “Booting” and the self test “Selftest”) and then the standard display:
Floor channel volumeCurrent volume setting for the conference units’ built-
in loudspeakers
Number of
conference units
Connection statusThe central unit is not connected to the
Structural change icon Icon appears when, since the last initialization, a
Cable fault iconIcon appears when a conference unit is not correctly
Short-circuit iconIcon appears when there is a short circuit in the
Warning triangleIcon appears when there is a malfunction/change. The
Audio recordingIcon appears when audio recording of the
Lock mode icon
(see page 14)
Number of conference units connected to the
conference system
“Conference Manager” software and/or a media
control unit.
The central unit is connected to the “Conference
Manager” software and/or a media control unit.
malfunction/change has occurred in the cabling of the
conference units.
connected to the ADN CU1 central unit.
cabling of the conference units. The display panel
lights up red.
display panel lights up red or orange.
conference is activated.
Icon flashes when storage space is low.
Icon appears when, after finishing the audio
recording, data is still written to the mass storage
device.
Icon appears when the audio recording failed. The
display panel lights up red.
Lock mode of the central unit is deactivated
Lock mode of the central unit is activated
For information on troubleshooting when error icons K to N are displayed, refer to
the detailed instruction manual “ADN Conference System”.
ADN CU1 | 5
Structuring and controlling the conference system
PORT I
PORT II
ADN CU1
max. 80 m
approx.. 2-5 m
52.8 V
>35 V
20
1
2 3
...
approx.. 2-5 m
max. 40
ADN D1/ADN C1
ADN CU1
Structuring and controlling the
conference system
Structuring the conference system
The ADN conference system is suitable for conferences with up to 400 conference
units. For safe operation of the conference system, make sure that all conference
units are supplied with a voltage of at least 35 V! The voltage supplied depends on
the number of connected conference units and on the cable lengths. The standard
cable length between the central unit or power supply and the first conference unit
is 80 m max. and the standard cable length between the individual conference
units is 2 to 5 m.
If these cable lengths are observed, safe operation of conference systems with the
following number of conference units is ensured:
•small conference systems comprising only an ADN CU1 central unit
– 30-40 conference units connected in simple strings
•large conference systems comprising an ADN CU1 central unit and a max. of
15 ADN PS power supplies
– max. 400 conference units connected in simple strings or in ring topology
per ADN PS power supply
– 60-70 conference units connected in simple strings
– 30-40 conference units connected in ring topology
If cable lengths are shorter, it might be that more conference units can be used.
ADN D1 delegate units and ADN C1 chairperson units can be combined in an arbi-
trary order. The number of chairperson units, however, is limited to 10 max. per
conference system. All components of the conference system are interconnected
using SDC CBL RJ-45 system cables.
Small conference system with simple cabling
For small conference systems with approx. 30-40 conference units, you require one
ADN CU1 central unit for controlling the conference. The conference units are interconnected in two cable strings which are directly connected to the central unit.
6 | ADN CU1
Structuring and controlling the conference system
PORT I/II
PORT I 2
PORT I 1
PORT II
1
PORT II 2
ADN PS
(max. 15)
ADN CU1
max. 80 m
approx. 2-5 m
52.8 V
>35 V
20
1
2 3
...
max. 80 m
ADN CU1
ADN PS
approx. 2-5 m
max. 70
ADN D1/ADN C1
Large conference system with simple cabling
For setting up a large conference system with the maximum number of conference
units (i.e. up to 400), you require one ADN CU1 central unit for controlling the conference and additional ADN PS power supplies for powering the conference units.
The conference units are interconnected in cable strings and up to four cable
strings can be connected to each ADN PS power supply.
ADN CU1 | 7