Sennetech SCT-1034 Quick Start Manual

SCT-1034
CAMERA CONTROL CODE TRANSLATOR
ERNITEC RS-485 TO BOSCH BIPHASE V er. 1.0
www.sennetech.net
Sennetech, Inc. 6455 W. Bath Rd. Perry, MI 48872 U.S.A. Ph (517) 675-1150 Fax (517) 675-1151
1 SCT-1034 Ver. 1.0
PRODUCT DESCRIPTION
The biphase output can be limited to fixed-speed-only commands for compatibility with older Burle receivers.
Input and output connections are made with mating screw terminal connectors. Front panel LEDs indicate status of power, receive, and transmit.
There is an optional 19" rack mount panel (one rack unit high).
SPECIFICA TIONS
SIZ E : 5.57"W x 1.52H x 5.45D WEIGHT : 1.5 lbs. POWER: 9Volt to 15V olt AC or DC at 75ma INDICAT ORS: Front panel LEDs: Power, Rx, & Tx RS-485 INPUT (2400 baud): (1) mating 3-pin screw terminal connector BIPHASE OUTPUT : (4) mating 3-pin screw terminal connectors
2
SETTING THE SWITCHES
T o set the configuration switches, remove the back panel, which is secured by two screws. Then slide the cover back to expose the switches. The switches can be changed while the code translator is powered up and the new settings will take effect immediately.
ON
CONFIGURATION
SWITCH
2345
1
OFF
SW1-1
BIPHASE CODE TYPE ON: VARIABLE SPEED OFF: FIXED SPEED
Set to ON if the receivers can accept variable speed biphase code Set to OFF for older receivers that only recognize fixed speed commands
67
8
3 SCT-1034 Ver. 1.0
INSTALLATION
REAR PANEL
RS-485 IN
S
Ernitec
BIPHASE DAT A OUTPUTSERNITEC
Bosch biphase
RS-485 input
Connect to the + and - lines
from the Ernitec controller
S = shield (optional)
(Data input is 2400 baud)
The four outputs are identical. Connect to the Bosch receiver
FRONT P ANEL
Power TxRx
CODE TRANSLATOR
outputs
biphase + and - lines
S = shield (optional)
S S S S
POWER
12V to 15V
AC or DC
Power
input
Power
indicator
Ernitec
receive
indicator
Flashes when
receiving RS-485
data
Bosch
transmit
indicator
Flashes continu­ously while sending biphase data
The Rx indicator will flash whenever there is data from the Ernitec controller. If the input lines have reversed polarity , the Rx indicator will be on solidly . Biphase code is repeating, so the Tx indicator will continue to flash while the camera is moving.
If you have Rx but no Tx, possible causes are:
The Ernitec code coming into the translator is not camera control code. The Ernitec data out is not set at 2400 baud.
If the code translator is sending data and does not get a follow-up Ernitec command in about 12 seconds, it will time out and quit sending that stream of data.
4
OPERATION
Pan, Tilt, Zoom, Focus, and Iris commands are converted directly. Ernitec Store and Recall pre-position commands are converted to Bosch Set and Shot com-
mands. Aux 1 is converted to Aux ON 1, which is interpreted by the Bosch domes as Autoscan (without
limits). Aux 2 is converted to Aux ON 2, which is interpreted by the Bosch domes as Autopan (within limits).
P AN & TIL T SPEEDS If the code translator is configured for fixed speed Bosch receivers, the Pan and Tilt commands have no speed value associated with them.
The Ernitec controller does not send speed values for Pan and Tilt commands. If the code translator is configured for variable speed Bosch receivers, the code translator will give
a speed value to Pan and Tilt commands. On power-up, the default is a medium speed. Aux 3 and Aux 4 are used to change the Tilt speed value. Aux 5 and Aux 6 change the Pan speed. Each time one of those Aux buttons is pressed, a small change is made to the associated speed.
Aux 3 Decrease tilt speed Aux 4 Increase tilt speed Aux 5 Decrease pan speed Aux 6 Increase pan speed
5 SCT-1034 Ver. 1.0
March 2003 SCT-1034 Ver. 1.0
6