Senci SC4000C, SC6500C, SC8000C Instruction Manual

DIESEL GENERATOR
Brief instruction manual
Air filter
Fuel handle
Recoil starter
Oil level Gauge
Battery
Handle
Key Starting
Earthing terminal
Air heating button
Low oil alert lamp
Single/Three phase switch
Socket
Reducing handle
Fuel cap
3 in 1 meter
Circuit breaker
Main operation parts
1
1815
592X460X500 760X530X615 760X530X615
76 113
117
231 456
499
70X60 88X75
92X75
12
8.3
QR170FBE KA188FE
KD192FE
004/032032
Voltage(AC)(V)
Alternator
1.1 1.65
1.65
Frequancy(Hz) 50 60 50
60 50 60
Max Power(KVA) 3 3. 3 5.5
6 7 8
Rated Power(KVA) 2.8 3 5
5. 5 6.5 7
Force-feed and splash
Recoil or Electric start
Diesel
gnE eni
Generator
1. 1 Main technical parameter
Diesel generator main technical parameter
SC4000C
SC6500C
SC8000C
Type
Single phase Single phase/ Three phases
Rotating speed( rpm) 3000 3600 3000
3600 3000 3600
Voltage(DC)(V )
Currency(DC)(A)
Model No.
Rated Power(KW)
3. 7 4 6.6
7. 5 7. 5 8. 2
Max Power(KW)
4 4. 4 /
/
/
BoreXStroke
Displacement(ml)
Cooling
Air cooling
Lubrication sys.
Oil capacity (L)
Starting sys.
Fuel type
Fuel tank capa.( L)
Weight(Kg
Dimension(mm)
2
1000 -1 5 40 <90%
1. 2 Model number
SC XXXX C
Diesel generator
Model number
Product series
1.3 Operation environment
Altitude(M)
Ambient temperature(℃) relative humidity
WARNING
A running engine gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide could result in death, serious injury, headache, fatigue, dizziness, vomiting, confusion, seizures, nausea or fainting.
• Operate this product ONLY outdoors.• Install a
battery operated carbon monoxide alarm near the bedrooms.
• Keep exhaust gas away from entering a confined area through windows, doors, ventilation intakes, or other openings.• NEVER operate this
product inside any building, carport, porch, mobile equipment, marine applications, or
enclosure, even if windows and doors are open.
3
The national Electrical Code requires that the frame and external electrically conductive part of this generator be properly connected to an approved earth ground. Proper grounding of the generator will help prevent electrical shock in the event of ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.
Earthing terminal
Preparation before starting
4
3.1 Fuel,Air filter and lubrication oil
Use clean and light diesel.
Notice:Forbidden to add diesel mixed with dust or water,otherwise will block the pump and injector
Model
Capacity
SC4000C SC6500C SC8500C
15
18 18
Fuel capacity(L)
Notice: Do not add fuel above the red mark indicated above.
Red mark
Fuel cap
Air filter
Forbidden cleaning of the filter.Displace the filter when it discharge oil in dropwise or abnormal.Forbidden to start the generator without air filter.
Start
Stop
Adjusting handle
Stop
tart
Notice:No smoking when adding
the fuel/engine oil and guarantee there is no fire around.Prevent overflow when
adding and fastening of the
screw.
5
Engine oil Put the generator in flat surface.Add engine oil and make sure its level between the upper limit and the lower limit.
SC4000C SC6500C SC8500C
Capacity( L)
1. 1
1. 65 1. 65
NOTICE:FORBIDDEN TO ADD OIL DURING OPERATION,DISCHARGE OIL ONLY THE
GENERATOR RIGHT AFTER OPERATION,IT IS HARD TO DISCHARGE ALL OIL WHEN
THE GENERATOR IS COLD.
NOTICE: ADD OIL BEFORE FIRST STARTING
Recommanded
Limitation
Suggested SAE 10W30,API CD or above oil
6
picture one
picture two
WARNING:GENERATOR MUST BE STARTED WITHOUT LOADING!
3. 3 FUEL PIPE EXHAUSTING SYSTEM
The generator can not starting when the oil is filled it is
probably the air has mixed in the fuel.The way to solve it is
close the fuel switch anticlockwise and loosen the clamp
between the fuel pipe and injection pump,then unplug the fuel
pipe and open the fuel switch clockwise till
there is no bubble from the fuel.
STARTING OF GENERATOR
Air heating button
4 STARTING OF GENERATOR Use Air Hearting button when the ambient temperature below 5 degree.Press this button 10 seconds before starting.
twist the fuel plug on the cover of the cylinder
THE COVER OF THE CYLINDER HEAD,OTHERWISE THE
DUST OR
WATER VAPOUR WILL BE SUCTION INTO.
Recoil start refer to the instruction pictures of next page.
Fuel plug
4. 1 Recoil start
NOTICE:When ambient temperature is low,
head and add 2 ml oil,then tighten.
NOTICE:THE FUEL PLUG MUST BE TIGHTEN ON
7
Open fuel switch
Put the speed control rod to the "RUN" position
Hold on to the starter
handle gently
Pull out slowly
Till you feel
resistance
Then release
it slowly
Repeat the above operation if can not start!
Now Start!
Pull it quickly at full
tilt,use both hands
when needed!
Hold on to the
starter tightly
Press reducing
handle and
then release
4. 2 Electrical start
( 1) Disconnect all loading equipment
( 2) Put the starting switch in "OFF" position
( 3) Open the fuel switch in "ON" position
( 4) Put the operation handle to "RUN" position
( 5) Turn the key clockwise to "START" position
NOTICE:The starting motor can not lasting too long time,
otherwise will burnt the motor and cause voltage drop of
the battery.
4. 3 Battery
Starting switch
Battery can be charged during running of the generator.
No need additional charge.
Battery
AVOID SPARK AROUND.
DANGER:FLAMMABLE HYDROGEN
WILL BE PRODUCED WHEN CHARGING,NO
SMOKE AND
8
9
OPERATION
5 OPERATION
5. 1. 1 AVOID OVERLOAD
OVERLOAD WILL DECREASE THE LIFETIME OF THE GENERATOR.USE IT IN
LIGHT LOAD IN THE FIRST 20 HOURS TO ENSURE THE RUN-IN PERIOD.
REPLACE OIL AFTER FIRST 20 HOURS RUNNING OR AT THE END OF THE
FIRST MONTH'S USING,THEN REPLACE EACH 50 HOURS.REPLACE OIL EACH
100 HOURS OR EACH 3 MONTHS AFTER THREE TIMES REPLACEMENT OF OIL.
5. 1. 2 PREHEAT THE GENERATOR 5 MINUTES WHEN DISCONTINUOUS
LOADING.
5.1.3 LOW OIL ALERT LAMP
Because low oil alert lamp fitted, it will light at low oil level or little oil, it keeps lighting if restart
the generator without add the oil. Check the oil level before starting, add the oil if needed.
5.2 CHECK THE GENERATOR DURING OPERATION
a) Excessive speed fluctuation, slow or fast
b) Overheating of the load wires
c) Sparks or electrical arcing within the generator
d) No voltage output
e) Socket damage or GENERATOR fire
f) Abnormal vibration
g) Flame or smoke
If any one of above occurs, please stop it immediately and contact the dealer.
5.3 OPERATING SPEED OF GENERATOR
Generators outputs normal voltage and under rated speed.
Running speed is adjusted well in factory. When connecting load, checking output voltage to
make sure the generator works well.
ADD LOADING
6 ADD LOADING
6.1 DETERMINE THE TOTAL LOADING OF GENERATORS
Determine the total loading which are connected to the generat
or is very important. The total
loading cannot exceed the rated power of the generator. The 2 main factors which affect the
generator’s lifetime is: winding temperature and winding corrosion. If the generator operates
overloaded, winding temperature becomes overheated, short-circuiting may occur after
long term operation.
Before starting the generator, make ensure the consistency between generator’s
nameplate data and electrical equipment’s power, voltage, current and frequency.
Because power is affected by equipment efficiency, power factor and other factors, some
equipments’ starting power is 3-10 times larger than runni
ng power.
REMINDER: IF ELECTRICAL EQUIPMENT’S POWER NOT SHOWN IN NAMEPLATE, IT
CAN BE
CALCULATED APPROXIMATELY BY VOLTAGE PLUS CURRENT(VOLTAGE x CURRENT).
Voltage × current = power Example: 220V × 5A = 1100W
10
NOTE: DO NOT LOSSEN OIL LEVEL LIMIT BOLT AND SPEED LIMIT BOLT, BOTH OF THEM
ARE ADJUSTED WELL IN FACTORY, OTHERWISE GENERATOR’S PERFORMANCE WILL BE
AFFECTED.
When adding load, all diesel generator’s rotational speed tends to decrease. When appliances are
connected to the generator and loading increased, it will result in engine speed decreasing and
output voltage lower compared with no-loading. If the generator does not reach the rated speed,
there will be no obvious affect for most of the loadings such as motors and lights but the electrical
appliances may be affected. The output voltage must be checked periodically to ensure proper
operation of generators and loadings. A portable voltmeter could be used to measure the voltage
while a tachometer to be used to measure the speed to get the working frequency.
5.4 MAINTENANCE OF GENERATOR
Generators must run every four weeks, keep no loading for 10-15 minutes,which could remove the
moisture and dust adsorbed on the windings. If not, the windings may be rusted and generator will
not operate properly.
When the load is a resistive load such as incandescent, heater or common power tools, using
electrical appliances can refer to rated power. If the load is inductive and resistive mixed loads
such as fluorescent lamps, mercury lamp, transformers, fans, small blowers or inductors,using
electrical appliances can only refer to 60% rated power.
NOTICE: WHEN GENERATOR REACH OPERATING SPEED THEN CAN ADD LOAD .
The following table list shows some household electrical appliances’ power for reference.
Reference table list of electrical appliances
equipment running power(w) equipment running power(w)
air condition(12,000) 170 0(a) lamp bulb 100
charger
20 A mp ) 500 microwave oven 700
chain saw 1200 milk cooler 1100(a)
circular sawφ15 mm ) 900 oil burner 300
coffee pot 1000 Oven 4500
perm machine 700 paint sprayer(1/3HP ) 600(a)
dish-washing machine 1200 paint sprayer 150
flat edge trimmer 500 Radio 200
electric staple gun 1200 Continuous loading
electric stove 1500 refrigerator 600(b)
electric stuffy pot 1250 attemperator 200
reefer 800(b) immersible pump(1-1/2HP) 2800(a)
Hair Dryer 1200 immersible pump(1HP) 2000(a)
electric hand drillφ25mm) 1100 immersible pump(1/2HP) 1500(a)
electric hand drillφ12mm) 875 trash pump(1/2HP) 600(a)
electric hand drillφ10mm) 500 bench saw 2000(a)
electric hand drillφ6mm) 250 television(10”) 500
flat edge trimmer 450 bread maker 1000
home computer 150 dust catcher 250
impact wrench 500 video player 70
household water pump 800(a) water heater 3000
hay mower 1200
(a) Cold to start the motor need 5-7 times rated current.
(b) Because the temperature of the compressor head requirements 15 minutes after restarting
6.2 START ELECTROMOTOR
When start electromotor need large current, some electromotor es
pecially phase motor with low
power is hard to start and needs 5-7 times running current. Capacitor start motor needs 2-4 times
running current. Permanent magnet motor need 1.5-2.5 times running current.
When overloaded, the generator will not run basis on the power characteristic curve, the rotate
speed of diesel engine doesn’t increase, which couldn’t output enough power to drive
electromotor to reach the working speed. The generator could make a response on a large initial
starting current. However, a sharp decline in engine speed, may cause generator stop. If allowed
to run with a very low speed, the motor windings will be abla
ted in a very short time, in this low
speed operation it could lead to the stator and motor windings burn out soon. Because of starting
a large current just a moment, When the generator speed quickly rises to the operating speed,
11
the generator will not damage. If starng the electromotor is difficult in a short me, turn o
other electrical loads and minimize the load of the electromotor.
6.3 CONNECTING WIRE
When supplying power some far from generator, connecng wire will be applied. The dimensions
of the wire used must conform to the requirements of the cross secon and length, in order to
keep the voltage drop within a very small value between electricity terminal and supply terminal.
NOTICE: USE A SMALL SIZE DIMENSION WIRE MAY CAUSE DIVICE DAMAGE.
6.4 AC APPLICATION
(1)Check the three in one meter display to make sure the current and voltage in allowed range,
then loading can be
added.
(2) Each loading must be connected on generator in order:
rst connecng larger loading, then smaller loading; rst connecng inducve loading, then
resisve loading. If order is reversed and cause generator’s speed decline sharply, loading must
be disconnect immediately.
(3) The balance of the three-phase generator load:
When a single phase loading connected on a three phase generator, each phase power can not
exceed 1/3 of the generang total power, each phase’s current D-value must be less than 20% of
the rated current.
If the circuit overload let switch trip for AC circuits, please reduce circuit loading.
If the voltage in
three in one meter shows too high or too low, shut down the generator to check the reason and
sweep the trouble, then restart.
6.5 DC APPLICATION DC binding post provides power source: DC12V 8.3A,red binding post is “+” pole of power source;
black binding post is “-“ pole of power source. The power source can be used in 12V DC load, as
well as can be used in charge baery.
(1)When charge generator baery by DC output which connected to the generator by wire, must
disconnect the wire “-“ pole which connected to the generator.
(2)Connect the baery “+” pole, “-“ pole separately with generator DC “+”
pole and “-“ pole by
charging wire.
REMARK: DC LOAD CURRENT CAN NOT EXCEED 8 A, WHEN CHARGE IN LARGE CAPACITY BATTERY,
THE FUSE OF DC SOURCE CAN BURN OUT EASILY DUE TO BIG CURRENT.
WARNING: DO NOT REVERSE THE CHARGING WIRE’S POSITIVE POLE AND NEGATIVE POLE. ONCE
REVERSED, CAN CAUSE A BAD DAMAGE IN GENERATOR AND STORAGE BATTERY. DO NOT LET THE
POSITIVE POLE CONNECT WITH NEGTIVE POLE, OTHERWISE CAN CAUSE SHORT CIRCUIT IN
BATTERY.
DANGER: THE BATTERY CHARGING CAN PRODUCE FLAMMABLE HYDROGEN GAS, KEEP AWAY
FROM SPARKS, FLAMES AND SMOKE WHEN
CHARGING. IN ORDER TO AVOID SPARKS NEARBY,
CONNECT THE STORAGE BATTERY FIRST, AND THEN CONNECTED TO THE GENERATOR,.WHEN
DISCONNECTED, FIRST DISCONNECTED THE GENERATOR SIDE. CHARGE BATTERY IN A WELL
VENTILATED PLACE.
6.6 SINGLE THREE PHASE OPERATION
Determine the load type before using single phase or three phase. Use the single/three phase
switch on the panel for selecon and judge the voltage and current by three in one meter.
12
WARNING: THE ELECTRICAL LOAD MUST BE DISCONNECTED WHEN USING SINGLE/ THREE PHASE
SWITCH.
STOP
7 STOP
Turn the starng switch to "OFF" posion, disconnect all the loadings in generator, leng the
generator running with no-loading for 3 minutes.
NOTICE: Do not stop generator suddenly because it may cause the generator’s temperature rise
abnormality, which will stuck nozzle and damage the generator.
The following steps should be take when need stop the generator:
(1)Turn the speed handle to “OFF” posion;
(2)Turn starng key to “OFF” posion;
(3)Aer generator stopped, turn the fuel switch to “OFF” posion.
(4)Pull out recoil handle slowly un
l feels resistance, pull back the handle slowly
NOTICE: THE LAST STEP CAN PREVENT IMPURITY INTO THE CYLINDER TO AVOID CYLINDER LINER
RUSTING
NOTICE: WHEN THE SPEED HANDLE LOCATE IN “STOP” POSITION AND THE GENERATOR IS STILL
RUNNING, TURN THE FUEL SWICH TO “OFF” POSITION OR LOOSEN HIGH PRESSURE OIL PIPE
BOLT.NO NEED TO USE REDUCING HANDLE.
GENERATOR MAINTENANCE
8 GENERATOR MAINTENANCE
8.1 REGULAR MAINTENANCE
To ensure the generator in good condion, regular inspecon and maintenance is very important.
Disconnect the storage baery’s wire connected to the generator when maintenance, rstly
disconnect negave pole wire, then posive pole wire. If diesel generator
must keep running
when maintenance, make sure of the venlaon nearby. Aer using generator, wipe clean it’s
surface traces of oil and dirt with cloth to prevent corrosion.
8.1.1 CHANGE OIL REGULARLY
Change oil aer the rst 20 hours or rst month of operaon, then every 50 hours. Change oil
every 100 hours or three month aer 3 mes oil change.
Twist o the oil level Gauge, unscrew the oil drain plug when diesel generator is sll hot to drain
used oil(Drain plug is in the boom of the cylinder block).Tighten the oil drain plug and add oil.
8.1.2 CLEAN THE OIL FILTER
Loosen the lock nut, take o
ut the oil lter and wash it with a clean petrol or kerosene.
8.1.3 CLEAN AND CHANGE THE AIR FILTER ELEMENT
Do not clean the air lter element with cleaner.Brush o the outer dirt of the air lter element
with a so brush.
NOTICE: DO NOT START THE DIESEL GENERATOR WITHOUT FILTER ELEMENT OR BREAKAGE.
8.1.4 Wash and change the fuel lter. Fuel lter must wash frequently to ensure a maximum
output power of diesel engine.
(1)Discharge the fuel from fuel tank;
(2)Loosen the small screw of fuel switch,take out the lter and clean the lter thoroughly with
diesel oil.
8.1.5 Tighten the cylinder head bolt
15
NOTICE: SPECIAL TOOLS WILL BE USED WHEN TIGHTEN THE CYLINDER HEAD SCREWS
8.1.6 Check the nozzle, high pressure pumps, etc.
8.1.7 Adjust the inlet and exhaust valve clearance.
8.1.8 Replace piston rings
NOTICE: DO NOT EXPOSE SKIN IN FUEL SPRAY WHEN OPERATION. FUEL CAN PENETRATE SKIN
AND CAUSE BODY HARM.KEEP AWAY FROM THE NOZZLE WHEN MEASUREING FUEL INJECTOR
ATOMIZATION SITUATION.
8.1.9 The GENERATOR use 12V storage ba
ery. Check ba ery before start. Replace it if it is
damaged.
8.2 THE MAINTENANCE OF THE LONG TERM STORAGE
If the generator will be stored for long
the following opera must be conducted.
8.2.1 Run genera
tor for 15 minutes, then stop it.
8.2.2 Discharge the oil when the generator is s
ll hot, then add new oil to specified height.
8.2.3 Unscrew out the oil plug on the cylinder head cover, and add 2ml lubrica oil, then ht
the oil plug.
8.2.4 Maintenance of start part
(1) Recoil start
Keep the fuel switch in the "OFF"
, press the reducing handle and don't loosen, pull the
st handle 2-3 es (not start diesel generator).
(2) Electrical start
Keep the fuel switch in the “OFF”
press the reducing handle and turn star ng key for 2-3
seconds, but don’t start the generator.
8.2.5 Pull out the reducing handle, pull out the recoil start slo
wly when feel resistance.
8.2.6 Remove the storage ba
ery from the generator in order to maintain monthly. To keep the
ba
ery voltage between 12-14V when storage, do not store the ba ery when the ba ery voltage
is lower than 10.8V to avoid damage.
8.2.7 Clean the generator and store it in a dry place.
CHECKING AND TROUBLESSHOOTING
9.1 CHECKING AND TROUBLESSHOOTING
Failure cause troubleshoo
ng
diesel fuel shortage add diesel
fuel
Fuel handle is not in the “ON”
turn the fuel handle to the “ON” po
High pressure pump, spray nozzle do not Overhaul of high-pressure pump, spray nozzle
spray or spray too li
le and to adjust in injector testbed
Governor is not in the “RUN”
turn the governor to the “RUN”
Check the oil level of the lubrica
oil the oil amount is between the “higher limit” and
“lower limit”
14
Recoil starter is not enough fast and strong to start the diesel GENERATOR according to
“operaon program”
Spray nozzle has dirt clean the spray nozzle
The storage baery has no electricity charging or changing
main switch is not closing turn it to the “ON” posion
Socket is band connecng adjust the socket feet
The engine didn’t reach the rated speed according to the requirement to achieve the
rated spe
ed
Blown fuse changing
Load electric leakage replace the load, reclosed
The engine didn’t reach to the rated speed 1.turn the governor arm to the limit posion
(apply to E type)
2.adjust the idle spring posion ll to the rated
speed (apply to XE, Q type)
Voltmeter is broken, pointer is ineffecve use another voltmeter to confirm GENERATOR’s
voltmeter is broken and changing
Voltmeter is broken, pointer is in
effecve use another voltmeter to confirm GENERATOR’s
voltmeter is broken and changing
AVR is broken or it’s wire isn’t connect change the AVR or reconnect
Lubricang oil is too lile, to protect add oil, the oil amount is between the “higher X,
XE,Q type limit” and “lower limit”
XXEQ
X’s, XE’s, Q’s governor arm are easy to escape repair simply, adjust the hook
According to the above method aer overhaul generators, if sll unable to start generator, please
contact the de
aler directly.
15