SELTEC Danfoss VLT 2800 How To Use Manual

How to use the Danfoss VLT 2800 Keypad

Press + or – Button to view different operating data
Press Quick Menu Button and then + Button to locate the required parameter in the Quick
Set-up Menu (Parameter number will ‘Flash’ when in this mode)
Press Change Data Button to open options (NOTE: When Data is a large figure, it will be shown as a row of dashes until Change Data Button is pressed).
Press + or Button to raise or lower data. (NOTE: the longer you hold the Button in the faster data will change).

Press Change Data Button to store data

Press + or – Button to move to next parameter or Press Quick Menu Button to go back to
Display Mode
To gain access to all other parameters in the Extended Menu, Press Quick Menu and + Button together this takes you into the first parameter 001
To get to the required Parameter, Press + Button, (remember the longer you hold in the button the quicker it will run through the parameters).
Press Change Data Button, Data for that parameter will now flash

Press + or – Button to raise or lower Data

Press Change Data Button to store

Press + or – Button to move to next Parameter or Quick Menu Button to go back to
Display Mode
Sick (Photocells, Barcode readers & Safety), ifm efector, Red Lion Controls, Hohner,
Danfoss (Drives, Pressure & Flowmeters), British Encoder Products, MTE Turck Banner,
Phoenix Contact, Rechner industries, Foxtam Controls, Di-ell industries, Contrinex,
Specialist Distributors for:
Allen-Bradley Multiswitch, Adam DAC Modules
Partners: J Dunnington, P Dunnington, M Dunnington
29 Partnership No: OC305579
CHANGING FROM AUTO TO HAND
From the ‘Display Mode’ Press Change Data Button and ‘Auto’ will appear in the display. Pressing the + Button will change the display to ‘Hand’
Display will then show ‘HA 00.0 then Press + or Button to raise or lower Frequency.
Parameter 020 could block the choice of mode
Terminal 27 needs to be on unless Parameter 013 has been changed.
MANUAL INITIALISATION
Disconnect mains, wait for Drive to discharge, Hold in Quick Menu and + and Change Data Buttons together then reapply mains and release the Buttons.
The Frequency Converter should now be back at factory settings.
Sick (Photocells, Barcode readers & Safety), ifm efector, Red Lion Controls, Hohner,
Danfoss (Drives, Pressure & Flowmeters), British Encoder Products, MTE Turck Banner,
Phoenix Contact, Rechner industries, Foxtam Controls, Di-ell industries, Contrinex,
Specialist Distributors for:
Allen-Bradley Multiswitch, Adam DAC Modules
Partners: J Dunnington, P Dunnington, M Dunnington
29 Partnership No: OC305579
Loading...