For assistance wit h ass e mbly co ntact :
Southern Enterprises Inc.
Customer Service 1-800-633-5096
service@seidal.com
www.seidal.com
OD964100TX
3-TIER BOWLS FOUNTAIN
Assembly Instructions
Page 1

Quantity
of 1
Fountain Body
of 1
Kit:
AC Adaptor model# GPU481201250WA00
Low voltage Pump model# PT-707(O)MIX-LV
Care and Maintenanc e :
Keep the water clean at all times.
Remove all forms of debris.
Never run the pump dry.
Verify water level frequently to compensate for evaporation. Fill within 1-2 inches below
the rim of the base.
Not for operation below 41° F (5° C). All water must be removed from the unit in freezing
conditions.
This fountain is for outdoor decorative use only.
This fountain is designed to function with water only.
Never leave a running fountain unattended.
The water in the fountain is not safe to drink.
Keep away from small children and pets.
Change the water regularly to prevent the proliferation of mosquitoes
INSTRUCTION FOR STORAGE: THE FOUNTAIN MUST BE STORED INDOORS
DURING WINTER OR WHEN TEMPERATURE IS BELOW 50°F (10°C)
During Winter, this fountain must be stored indoors Please follow the following steps:
-Disconnect power supply
-Carefully empty fountain of all water
-Store Indoor on water resistant surface
For
replacement part s or questio ns,
please
Call Customer Service at
1-800-633-5096
OD964100TX—3-TIER BOWLS FOUNTAIN
Parts List
Carefully c heck all p ackaging m aterials be fore discar ding. Do n ot assemble if there are missi ng
pieces and call Custo mer Ser vice.
Page 2

1- Place the base onto a firm level surface that won’t
be damaged by water.
2- Put the small bowl in place .Thread the hose
through the hole in the top of the fountain as the
upper bowl is lowered into place.
3- Connect the pump to the hose. Make sure the
pump is sitting on the bottom and t he hose is not
kinked.
4- Put the pump cover in place
5- Plug the pump cord into a proper ly grounded
outlet.
6- Fill with clean water.
—3-TIER BOWLS FOUNTAIN
Assembly Instructions
Page 3

To reduce the risk of electrical shock, use pump only on
contained fountains no larger than 5 feet (1.5 m) in any
dimension.
Precautions:
- Excessive weight or pressure
on any of the fountain sections
may cause it to tip or fa ll over. Keep pets and children away fr om
any of the fountain sections. Do not place any items, su ch as
potted plants, on the edge of the bowl.
- If the entire fountain falls into the water accidentally, turn off the
circuit breaker immediate ly before man ipu lati ng.
- Do not operate the founta in if t he pump ha s been dro pped or has
a damaged power cord or plug.
-
If the plug or your wall receptacle gets wet due to water dripping
down the power cord or for any other reason, do not remove the
plug from the wall outlet until the circuit breaker is turned off.
- NOTE: Allow the pump power cord to hang at a lower level than
the wall outlet to form a “drip loop.” This will help prevent water
from dripping down the
power cord and getting into the wall
Periodically change the water. Clean the fountain water basin,
the pump’s outlet nozzle and the water tube for dirt and debris
with a damp cloth if necessary.
- Keep the power cord away from high temperatures or heat
sources.
Use only a CUL or CSA or CETL approved extension
cord of the correct rating to avoid overheating.
Do not use attachments, which are not provided by the manufacturer,
since they may cause an unsafe condition.
- This fountain pump is not intended for commer c ial use .
WARNING! RISK OF ELECTRICAL SHOCK!
This pump is supplied with a grounding conductor and
grounding type plug. To reduce the risk of electric
shock, be certain that it is connected to a properly
grounded, grounding type receptacle.
Always disconnect power supply before manipulating
fountain.
Connect only to a grounded outdoor power outlet of 120V-
60Hz.
Do not attempt to repair a damaged pump/power cord.
Ask for a replacement pump/cord from the
manufacturer.
To avoid possi
ble injuries do not tamper with
Must be used only with the pump AND/OR transformer
Be careful not to spill water onto the plug of the
pump.DO NOT allow the pump to run dry!
—3-TIER BOWLS FOUNTAIN
Warning

Please immediately examine this product carefully. Any request for missing parts or damage replacement must be
received within 90 days of your receipt of the product. Replacement, if available, will be honored within this time
frame. Parts will not be available for items arriving fully assembled. We do not r ecommend modifying product(s)
and we are not responsible for any damages due to product modification(s).
If damages or missing parts are not
reported within 90 days of your receipt, we are under no obligation to provide parts or replacement merchandise.
Please contact Southern Enterprises at 800-633-5096 or in Dallas 972-869-0111/ 9am – 4pm Mon-Fri Central time
if you have product issues or email us at service@seidal.com. Please ask for customer service representative for
issues involving damages or replacement parts. Please ask for technical assistance representative for any issues
with product and assembly/construction.
Please contact the retailer that you purchased from for returns.
Cust omer Information
Name
Address
City/State/Zip Code
Phone Number
Please indicate where you purchased this item: Store/Website/Catalog
Please indicate color/size/style number:
Style No Parts Letter Parts Description Quantity Needed
Customer Service 1-800-633-5096
service@seidal.com
Southern Enterprises, Inc.
600 Freeport Parkway, Suite 200
Coppell, Texas 75019