SEEED GRV PIR MOTION Datasheet

BISS0001
Micro Power PIR Motion Detector IC
===========================================
Features
Low power CMOS technology (ideal for battery operated PIR devices) CMOS high input impedance operational amplifiers Bi-directional level detector / Excellent noise immunity Built-in Power up disable & output pulse control logic Dual mode : retriggerable & non-retriggerable
Pin description

Pin Number Symbol Description

1
2 3 4 5 6 7 8
9
10 11 12 13 14
15 16
* Tx = The time duration during which the output pin (Vo) remains high after triggering. Ti = During this time period, triggering is inhibited. See timing charts for details.
A Retriggerable & non-retriggerable mode select
(A=1 : re-triggerable)
VO Detector output pin (active high) RR1 Output pulse width control (Tx) * See definition below RC1 Output pulse width control (Tx) * RC2 Trigger inhibit control (Ti) * RR2 Trigger inhibit control (Ti) *
Vss Ground
VRF RESET & voltage reference input
(Normally high. Low=reset)
VC Trigger disable input
(VC >0.2Vdd=enable; Vc<0.2Vdd =disabled)
IB Op-amp input bias current setting
Vdd
2OUT
2IN
+
1IN
1IN
1OUT
Supply voltage 2nd stage Op-amp output 2nd stage Op-amp inverting input
­1 st stage Op-amp non-inverting input
1 st stage Op-amp inverting input
­1 st stage Op-amp output
Tx 24576 xR10 x C6 Ti 24 x R9 x C7 (ref to schematic)
Absolute max. ratings
Description Condition Range Unit
Supply voltage -- 3 ~ 5 V
Input voltage -- Vss-0.3~ Vdd+0.3 V
Output current Vdd=5V 10 mA
Operating
temperature
Storage
temperature
-- -20 ~ +70
-- -40 ~ +125
Retrigerrable waveform
(NOTE : VH=0.7Vdd, VL=0.3Vdd)
°C
°C
Non-retriggerable waveform
(NOTE : VH=0.7Vdd, VL=0.3Vdd)
Internal Block Diagram
Tx – Output pulse width control Ti - Trigger inhibit timing control
Application Example
-- Passive Infrared Detector for alarm system
Tx 24576 x R10 x C6 Ti 24 x R9 x C7。 (ref to schematic)
R3
is a light dependent resistor which has low resistance under strong ambient light. This causes the detector to be operational only when the detection area is sufficiently dark.