SEDONA by LYNX™ VENT HOOD
CARE & USE/INSTALLATION
1
![](/html/f1/f1d3/f1d3da9b3412e18ea4c474e970ad1eadb19b7f71349f08eef6a4ed4fbad29862/bg2.png)
WARNINGS
WARNINGS and CAUTIONS: Must be followed carefully to avoid personal
injury, damage or incorrect installation.
TIPS: Contains helpful information to facillitate installation.
WARNING
READ THIS MANUAL CAREFULLY and completely before using your vent hood to reduce the risk of:
1. Fire
2. Electric Shock
3. Personal Injury
4. Unapproved installation
THIS PRODUCT IS DESIGNED FOR OUTDOOR USE ONLY. Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or death.
Read this manual thoroughly before installation, use, or servicing of this product.
WARNING
1. Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact
the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel, lock service panel and lock the service
disconnection means to prevent power from being switch on accidentally. When the service disconnection
means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
This product complies with ANSI/NFPA 70-1990 (or latest revision)
and approved by Underwriters Labratory.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION2
|
To obtain replacement parts or service contact:
Lynx Grills, Inc.
7300 Flores Street
Downey, CA 90242
888-289-5969
![](/html/f1/f1d3/f1d3da9b3412e18ea4c474e970ad1eadb19b7f71349f08eef6a4ed4fbad29862/bg3.png)
TO REDUCE THE RISK OF A BBQ TOP GREASE FIRE:
a) Never leave surface units unaended at high sengs. Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium sengs.
b) Always turn hood ON when cooking at high heat or when ambéing food (i.e. Crepes Suzee, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean venlang fans frequently. Grease should not be allowed to accumulate on fan or lter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A BBQ TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-ng lid, cookie sheet, or metal tray, then turn o the burner. BE CAREFUL TO
PREVENT BURNS. If the ames do not go out immediately, shut o the gas, EVACUATE AND CALL THE FIRE
DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN—YOU MAY BE BURNED.
c) DO NOT USE WATER, including wet dishclothes or towels - a violent steam explosion will result.
d) Use an exnguisher ONLY if:
1. You know you have a Class ABC exnguisher and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit.
e) Follow the barbeque grill manufacturer’s instrucon when using gas grills, cookers, or any propane appliances.
f) BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
Recommendaons:
1. Consult a licensed venlaon contractor or qualied technician for proper installaon of exhaust ducng.
Locate the cooking area for minimum cross dras.
2. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep
turning radius as large and as smooth as possible.
3. The ducng must be air ght. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct
joints with high quality duct tape.
4. Do not use this unit with any solid-state speed control device.
5. This unit must be grounded.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
3
|
![](/html/f1/f1d3/f1d3da9b3412e18ea4c474e970ad1eadb19b7f71349f08eef6a4ed4fbad29862/bg4.png)
INSTALLER: Read these instructions carefully before starting installation. Please leave these instructions with
the homeowner.
HOMEOWNER: Please retain these instructions for future use
Exterior Dimensions
Width D Height E Depth F
36” 24” 32”
42” 24” 32”
48” 24” 32”
3/4”
2 1/2”
32”
E
24”
F
15”
8”
36”, 42”, 48”
10”
2 1/2”
D
Exterior Dimensions
The Sedona by Lynx ™ vent hoods are designed for outdoor use. It is recommended that the vent hood be installed by a
qualified technician in accordance with all local building codes.
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Please be advised that the Sedona by Lynx™ Vent Hood MAY NOT be installed on a Patio or Lanai area that does not
have a roof over the Grill Hood to protect it from direct rain or potential water ingress. This Hood should be installed
with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that are not protected from direct rain by
an adjacent wall.
It is required that all duct work and roof openings be thoroughly sealed with the applicable tape and/or roof sealant to
prevent ingress of water.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION4
|
![](/html/f1/f1d3/f1d3da9b3412e18ea4c474e970ad1eadb19b7f71349f08eef6a4ed4fbad29862/bg5.png)
WARNING
To Reduce The Risk Of Fire, Electric Shock, Or Injury To Persons, Observe The Following:
To Reduce The Risk Of Fire, Use Only Metal Ductwork. To reduce the risk of fire and to properly exhaust air,
be sure to duct air outside – Do not vent exhaust air into spaces with in walls or ceilings or into attics, crawl
spaces, or garages.
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and standards.
b) Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety
standards such as those published by the National Fire Protection Association (NFPA) and the American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) For safe and secure wall mounting, the Sedona by Lynx™ Vent Hood should be mounted to a solid vertical surface
of sufficient width to allow for mounting of the Hood. The horizontal surface should extend from a vertical plane
to the point directly in front of the exhaust roof cap (or wall cap).
f) The Hood should be installed with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that
are not protected from direct rain by an adjacent wall.
g) It is also required that all duct work and roof openings be thoroughly sealed with the applicable tape and/or roof
sealant to prevent ingress of water.
WARNING
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never exhaust into
a wall, an attic or a concealed area in the building. This can create a potential hazard.
3. Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.
4. Locate the cooking area for minimum cross drafts.
5. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep
turning radius as large and as smooth as possible.
6. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints
with high quality duct tape.
7. Only use ductwork constructed of materials deemed acceptable by state, municipal and local codes.
8. Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide
minimum clearances, unless otherwise specified.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
5
|
![](/html/f1/f1d3/f1d3da9b3412e18ea4c474e970ad1eadb19b7f71349f08eef6a4ed4fbad29862/bg6.png)
INSTALLING THE VENT HOOD
...continued
All dimensions are nominal +/- 1/8”l
3/4”
2 1/2”
Note- Two additional electrical
15”
10”
2 1/2”
holes located on the back of the
unit (not shown). Approximately
3/4" from the top and 2 1/2"
8”
36”, 42”, 48”
Drawing Model Size CFM 3-Speed
32”
Motors
24”
Halogen
Lights
SS Baffle
Filters
from the sides.
Top
Discharge
A SVH36 36” 1200 X X X X X
A SVH42 42” 1200 X X X X X
A SVH48 48” 1200 X X X X X
Variable
Light
Control
10” Discharge out of top only (for Rear Discharge, use a 10” 90° elbow, not provided)
Optional duct
cover extension
for up to 12’
ceilings
15”
24”, 30”, 36”
Included duct
cover for up to
10’ ceilings
15”
13” to 24”
12”
24”, 30”, 36”
SDC1236 Ext Kit for SVH36
SDC1242 Ext Kit for SVH42
SDC1248 Ext Kit for SVH48
25” to 48”
24”
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION6
|