WARNINGS and CAUTIONS: Must be followed carefully to avoid personal
injury, damage or incorrect installation.
TIPS: Contains helpful information to facillitate installation.
WARNING
READ THIS MANUAL CAREFULLY and completely before using your vent hood to reduce the risk of:
1. Fire
2. Electric Shock
3. Personal Injury
4. Unapproved installation
THIS PRODUCT IS DESIGNED FOR OUTDOOR USE ONLY. Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or death.
Read this manual thoroughly before installation, use, or servicing of this product.
WARNING
1. Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact
the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel, lock service panel and lock the service
disconnection means to prevent power from being switch on accidentally. When the service disconnection
means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
This product complies with ANSI/NFPA 70-1990 (or latest revision)
and approved by Underwriters Labratory.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION2
|
To obtain replacement parts or service contact:
Lynx Grills, Inc.
7300 Flores Street
Downey, CA 90242
888-289-5969
BEFORE YOU START
TO REDUCE THE RISK OF A BBQ TOP GREASE FIRE:
a) Never leave surface units unaended at high sengs. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium sengs.
b) Always turn hood ON when cooking at high heat or when ambéing food (i.e. Crepes Suzee, Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean venlang fans frequently. Grease should not be allowed to accumulate on fan or lter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A BBQ TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-ng lid, cookie sheet, or metal tray, then turn o the burner. BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately, shut o the gas, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN—YOU MAY BE BURNED.
c) DO NOT USE WATER, including wet dishclothes or towels - a violent steam explosion will result.
d) Use an exnguisher ONLY if:
1. You know you have a Class ABC exnguisher and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit.
e) Follow the barbeque grill manufacturer’s instrucon when using gas grills, cookers, or any propane appliances.
f) BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
Recommendaons:
1. Consult a licensed venlaon contractor or qualied technician for proper installaon of exhaust ducng. Locate the cooking area for minimum cross dras.
2. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep turning radius as large and as smooth as possible.
3. The ducng must be air ght. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints with high quality duct tape.
4. Do not use this unit with any solid-state speed control device.
5. This unit must be grounded.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
3
|
EXTERIOR DIMENSIONS
INSTALLATION PREPARATION
INSTALLER: Read these instructions carefully before starting installation. Please leave these instructions with
the homeowner.
HOMEOWNER: Please retain these instructions for future use
Exterior Dimensions
Width DHeight EDepth F
36”24”32”
42”24”32”
48”24”32”
3/4”
2 1/2”
32”
E
24”
F
15”
8”
36”, 42”, 48”
10”
2 1/2”
D
Exterior Dimensions
The Sedona by Lynx ™ vent hoods are designed for outdoor use. It is recommended that the vent hood be installed by a
qualified technician in accordance with all local building codes.
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Please be advised that the Sedona by Lynx™ Vent Hood MAY NOT be installed on a Patio or Lanai area that does not
have a roof over the Grill Hood to protect it from direct rain or potential water ingress. This Hood should be installed
with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that are not protected from direct rain by
an adjacent wall.
It is required that all duct work and roof openings be thoroughly sealed with the applicable tape and/or roof sealant to
prevent ingress of water.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION4
|
INSTALLING THE VENT HOOD
WARNING
To Reduce The Risk Of Fire, Electric Shock, Or Injury To Persons, Observe The Following:
To Reduce The Risk Of Fire, Use Only Metal Ductwork. To reduce the risk of fire and to properly exhaust air,be sure to duct air outside – Do not vent exhaust air into spaces with in walls or ceilings or into attics, crawlspaces, or garages.
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and standards.
b) Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety
standards such as those published by the National Fire Protection Association (NFPA) and the American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) For safe and secure wall mounting, the Sedona by Lynx™ Vent Hood should be mounted to a solid vertical surface
of sufficient width to allow for mounting of the Hood. The horizontal surface should extend from a vertical plane
to the point directly in front of the exhaust roof cap (or wall cap).
f) The Hood should be installed with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that
are not protected from direct rain by an adjacent wall.
g) It is also required that all duct work and roof openings be thoroughly sealed with the applicable tape and/or roof
sealant to prevent ingress of water.
WARNING
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never exhaust into
a wall, an attic or a concealed area in the building. This can create a potential hazard.
3. Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.
4. Locate the cooking area for minimum cross drafts.
5. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep
turning radius as large and as smooth as possible.
6. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints
with high quality duct tape.
7. Only use ductwork constructed of materials deemed acceptable by state, municipal and local codes.
8. Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide
minimum clearances, unless otherwise specified.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
5
|
INSTALLING THE VENT HOOD
...continued
All dimensions are nominal +/- 1/8”l
3/4”
2 1/2”
Note- Two additional electrical
15”
10”
2 1/2”
holes located on the back of the
unit (not shown). Approximately
3/4" from the top and 2 1/2"
8”
36”, 42”, 48”
DrawingModelSizeCFM3-Speed
32”
Motors
24”
Halogen
Lights
SS Baffle
Filters
from the sides.
Top
Discharge
ASVH3636”1200XXXXX
ASVH4242”1200XXXXX
ASVH4848”1200XXXXX
Variable
Light
Control
10” Discharge out of top only (for Rear Discharge, use a 10” 90° elbow, not provided)
Optional duct
cover extension
for up to 12’
ceilings
15”
24”, 30”, 36”
Included duct
cover for up to
10’ ceilings
15”
13” to 24”
12”
24”, 30”, 36”
SDC1236 Ext Kit for SVH36
SDC1242 Ext Kit for SVH42
SDC1248 Ext Kit for SVH48
25” to 48”
24”
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION6
|
ELECTRICAL CONNECTIONS
WARNING
Hood
House Electrical
Green or bare wire
White
120V Black (L)
• The following are Manufacturer’s Suggestions. Always Observe Local Building Codes.
Hoods installed in custom canopies constructed of combustible materials should be installed with the
combustible material structure a minimum of 36” above the cooking surface. Hoods installed in custom
canopies constructed of non-combustible materials, should be installed with the non-combustible material
structure a minimum of 30” above the cooking surface. Follow all instructions regarding minimum safe clearances
and installation location. Failure to do so may result in a safety hazard or fire. To reduce the risk of fire use only
metal ductwork.
Ensure that the power supply is disconnected before proceeding. Verify that the power supply matches the ratings
found on the appliance data label before proceeding. The complete appliance must be properly grounded at all times
when electrical power is applied. Do not ground the appliance with the neutral (white) house supply wire. A separate
ground wire must be utilized. Failure to complete electrical connections properly may result in damaged or
non-functional systems. Follow instructions carefully to ensure proper installation.
It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this
appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric
Code ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this standard may be
obtained from:
National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471
Important Electrical Requirements: Observe all National and local governing codes and ordinances. Have all
electrical installation done by a qualified electrical installer. This Hood requires a 120 Volt, 60 Hertz electrical supply of
an individual properly grounded branch circuit protected by a 15 or 20 Amp circuit breaker.
The Sedona by Lynx™ Vent Hood is supplied with a 6.0 Amp three speed fan control.
For safety precautions, each Ventilation Hood should be installed in a GFCI protected branch circuit.
WIRE CONNECTIONS
There are 3 wires on the front panel that require
connection.
BLACK 120 VAC from electrical panel (usually black)
WHITE Neutral from electrical panel (white)
GREEN Ground from electrical panel (usually green)
CAUTION: The neutral wire (white) must only be
connected to the white neutral wire coming in
from the electrical panel.
Panel
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
7
|
SECURING THE HOOD
MOUNTING HOLES:
Because the Sedona by Lynx™ Vent Hood was designed for all applications, no mounting holes have been pre-drilled.
This allows for custom applications for mounting. The hood should be attached to the framing through the top and back,
whenever possible. Remove the filters. Mark and drill screw holes through the hood as required. Secure the hood by
driving screws (provided by others) through the screw holes.
**NOTE: DRILLING THROUGH STAINLESS STEEL REQUIRES TITANIUM DRILL BITS. BE CAREFUL NOT TO DRILL
THROUGH THE UL LABEL OR INTO THE HOOD’S ELECTRICAL COMPONENTS
CARE AND USE
OPERATING CONTROLS:
Always activate the ventilator when using cooking appliances. Activate the ventilator a few minutes before starting to
cook to establish an airflow pattern within the room. Adjust the fan speed as needed. Adjust the dimmable halogen
lights as desired.
WARNING
Do NOT operate the blower / ventilator system without the filters in place, or with dirty, grease laden
filters.
ENERGY SAVING TIPS:
Do not operate the blower at a speed higher than necessary to remove the cooking exhaust. Turn off the unit once the
smoke and cooking odors have been eliminated. Clean filters and grease laden surfaces often to improve efficiency.
CARE AND CLEANING:
Proper cleaning is necessary to maintain performance and appearance, while also ensuring safe operation. The frequency
of cleaning should be adjusted according to the type and amount of cooking. Best results will be achieved by cleaning
soiled components as soon as possible. Filters must be cleaned regularly. Using the aluminum knob, lightly pull the filter
toward the front of the liner while pulling the backside downwards. Replacing the filter is just as easy as taking it out.
The filters may be cleaned by hand washing in hot water using a mild detergent solution, or by placing them in a dishwasher. Locate holes on the sides of the filter. Put filter in dishwasher with holes facing up so detergent can enter filters.
Dry the filters completely before using again. Rinse and dry with a soft lint-free cloth. Always wipe stainless steel surfaces
with the grain. Never wipe across the grain. After cleaning, reinstall the filters carefully.
>> Most common scrubber type pads will scratch the hood, do not use them to clean the hood.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION8
|
CARE AND USE
...continued
If a commercially available stainless steel cleaner is used, it is important to read the labels for chlorine
compounds. Chlorine is a corrosive substance, DO NOT USE. Follow polish manufacturer’s instructions.
HALOGEN LIGHT BULBS:
Hoods are designed for halogen light bulbs (PAR20). They can be purchased at most home improvement and/or grocery
stores.
We endeavor to incorporate the best technology provided to our industry, in manufacturing Sedona by Lynx™
products, therefore, we reserve the right to change models, mode of operation, and specification without prior
notice.
IMPORTANT: Problems caused by improper installations are not covered by the manufacturer’s warranty.
IMPORTANT: Undersized and improperly installed duct pipe and/or other ventilation components will cause
excessive static pressure (air resistance), that may result in rattling, vibration and air buffeting noises, as well as
inadequate ventilation.
1. Building Codes
Vent hoods should be installed by qualified technicians familiar with state and local building codes.
Use round or rectangular rigid metal duct only. Where possible, use round duct as it creates the least amount of
static pressure. DO NOT use flex duct.
All duct sections and fittings (EXCEPT DAMPERS, per Section 4), should overlap and be connected with at least
3 – 4 equally spaced screws and wrapped tightly with 2 – 3 layers of Aluminum Foil Metal Duct Tape. This type
of duct tape is more durable than traditional cloth duct tape. DO NOT use butt joints.
For best air flow, elbows and pipe size transition fittings should not be directly connected to one another. Where
possible, always include at least 15 inches of straight pipe between fittings.
3. Duct Pipe and Fitting Sizes
IMPORTANT: No portion of any length of duct pipe or fitting should be smaller than the discharge port of the
ventilator. This is very important because any type of restriction anywhere in the ventilation system will cause
increased static pressure (air resistance), that may result in rattling, vibration and air buffeting noises, as well as
inadequate ventilation. See Duct Sizing Chart and Area Calculations section for more detail.
Duct Runs – Length
Configure the ventilation duct run to be as short and as direct to the outside as possible.
Minimize the number of elbows and transition fittings used. Complex or long runs should be
reviewed by a qualified installer.
No portion of the ducting should be run so that the exhaust air flows downward. Since exhaust heat rises,
forcing the air to flow downward will cause increased static pressure. As previously mentioned, improperly
installed duct pipe will cause excessive static pressure (air resistance), that may result in rattling, vibration and air
buffeting noises, as well as inadequate ventilation.
Duct runs for 1200CFM ventilator models should not exceed 35 linear feet with two
90-degree elbows and two 45-degree elbows, and a roof or wall cap. Longer runs or additional elbows will
result in decreased ventilation performance. Each 90-degree elbow is the equivalent of 6 linear feet of duct
pipe; each 45-degree elbow is equivalent to 3 linear feet of duct pipe.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
9
|
Always run ventilator ducts to the outdoors. DO NOT terminate a duct into an attic,
CARE AND USE
...continued
basement, garage, crawl space under a house, a chimney, other ducting or an enclosed room.
4. Dampers
IMPORTANT: DO NOT USE ANY TYPE OF DAMPER IN A VENT HOOD APPLICATION.
In ventilation systems utilizing a roof cap or wall cap
with
a built-in damper, remove it. Dampers are unnecessary and will
cause increased static pressure (air resistance), that may result in rattling, vibration and air buffeting noises, as well as
inadequate ventilation.
5. Roof Caps and Wall Caps
The roof cap or wall cap is the termination point of the venting system that allows the exhaust air to exit
to the outdoors. All sections of this fitting must have an equal or greater air path area than the ventilator’s
discharge port. If any section of the roof cap or wall cap is smaller than the ventilator’s discharge port, the
entire ventilation system will lose efficiency and the restriction will cause increased static pressure and decrease
performance.
IMPORTANT: Even though the intake side of the roof cap or wall cap may be properly sized, roof caps or wall caps
with built-in dampers should not be used. The actual open area of the final air path must equal to or greater than
the discharge port of the ventilator. Any undersized portion of a roof cap or wall cap will cause excessive static
pressure that may result in rattling, vibration and air buffeting noises, as well as inadequate ventilation.
Do Not use “goose-neck style” caps as they significantly restrict natural, heated air-flow. Do Not use caps with dampers
for Vent Hoods.
10”
10”
Opening 35”
Opening 100 sq. in.
3.5”
10”
Please see next
page for
24”
drawing of
optimum
performance
roof cap.
The air exit opening on the roof cap used needs to be at or above 78.5 square inches. See illustrations
above. Never use a roof cap like the one shown in Figure 1. Instead use a style similar to the one shown in
Figure 2.
6. Attaching Duct to House Framework
The ventilation system should be attached to the framework in such a manner that the weight of the duct
and fittings is supported with no stress on the duct joints, fittings or on the ventilator. All ducting should be
attached so as to avoid any possible duct vibration from being transferred to the house’s framework.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION10
|
Diameter 9 3/4”
CARE AND USE
...continued
7. Duct Sizing Chart and Area Calculations
Minimum Discharge
Ventilator Discharge
Port Types & Sizes
6” Diameter, Round28.3”6” Round Metal Duct28.3”28.3”
7” Diameter, Round38.5”7” Round Metal Duct38.5”38.5”
Duct Type Required
Duct Size
(in Square Inches)
Size of Roofcap or
Wallcap Outside
Opening
8” Diameter, Round50.25”
10” Diameter, Round78.5”10” Round Metal Duct78.5”78.5”
3.25” x 10” Rectangular32.5”3.25” x 10” Rectangular Metal Duct32.5”32.5”
Formulas for Calculating Square Inches of Various Duct Sizes and Types
Round Duct Rectangular Duct
RadiusxRadiusx3.1416=
The “radius” is one-half the diameter of a round duct, e.g., 1/2”
of a 10” round duct is 5”. 3.1416 is “Pi” the “constant” used
when calculation the area of a circle.
8” Round Metal Duct or
6” x 9” Rectangular Metal Duct
Area (Sq.
Inches)
WidthxDepth=Area (Sq. Inches)
50.25”
54”
50.25”
54”
8. Best Smoke Capture Recommendations
Smoke and hot air from an Outdoor BBQ Grill rises quickly, especially as the BBQ lid is opened. Not only does
the smoke rise fast, but it is usually deflected forward (toward the cook) beyond the BBQ hood’s capture area by
the shape and position of the BBQ lid itself. Heavy, fast rising smoke is a challenge even for high-performance
vent hoods, but there are some things you can do to enhance your outdoor vent hood’s performance.
a. Install the hood at least 30”, but no more than 44”
above the cooking surface. If the hood is installed more than
44” above the cooking surface, its’ smoke capture ability
declines rapidly. See Drawing A.
b.Since smoke also expands as it rises, the hood’s sides
and front edge should extend 3” – 6” beyond the front and
sides of the cooking surface—see Drawing B. In this example,
the hood is attached to a built-out section of the wall or to a
chase.
It is unlikely that smoke rising past the bottom of the vent hood
will be captured by the hood. Smoke escaping the hood’s
capture area will typically remain against the ceiling until it is
blown out by natural air currents or until it dissipates.
c.Turn the hood on high 2 -3 minutes prior to placing
food on the grill. If there is no wind or wind drafts, an upward
flowing air “curtain” will be created by the hood’s suction that
moves air up the sides and front of the cooking surface. This
upward moving air curtain will help capture much of the smoke.
d.Wind and wind drafts will also negatively affect the
capture ability of high-performance outdoor vent hoods. If
the BBQ grill is located in a consistently windy area, e.g., near
oceans, large lakes or on hillside properties, for best vent hood
performance, a wind-break may be required.
30”- 44”
6”
A
B
30”- 44”
6”
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
11
|
ROOF CAP DRAWING
*Required dimensions for roof cap - Minimizes static pressure and maximizes air flow to ensure optimum
performance of your Sedona by Lynx™ product.
12”
11”
A
16”
12” Open
10”
24”
DETAIL A
SCALE 1:6
24” x 24” flashing
9 7/8” x 2” collar
8”-12”
10”
10”-14”
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION12
|
LYNX LIMITED WARRANTY
I. Limited Three-Year Warranty
The stainless steel housing is warranted to be free from defects in material and workmanship when subjected to normal domesc
use and service for three years from the date of purchase for the original purchaser. This warranty excludes surface corrosion,
scratches, and discoloraon which may occur during regular use. This warranty is limited to the replacement of the defecve parts,
with the owner paying all other cost including labor.
II. Limited ONE-Year Warranty
All other components are warranted to be free from defects in material and workmanship for a period of one year from the original
date of purchase. Lynx will replace or repair parts found to be defecve at no cost to the original purchaser.
III. Limitaons & Exclusions
1. This Warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the
country where service is requested.
2. Warranty applies only to the original purchaser and may not be transferred.
3. Warranty is in lieu of all other warranes expressed or implied and all other obligaons or liabilies related to the sale or use of
its products.
4. Warranty shall not apply and Lynx is not responsible for damage resulng from misuse, abuse, alteraon of or tampering with the
appliance, accident, hosle environment, improper installaon, or installaon not in accordance with the instrucons contained
in this manual, or the local codes.
5. Lynx shall not be liable for incidental, consequenal, special or conngent damages resulng from its breach of this wrien
warranty or any implied warranty.
6. Some states do not allow limitaons on how long an implied warranty lasts, or the exclusions of or limitaons on consequenal
damages. This warranty gives you specic legal rights and you may have other rights which vary from state to state.
7. No one has the authority to add to or vary Lynx’s warranty, or to create for Lynx any other obligaon or liability in connecon with
the sale or use of its products.
8. Limited to the replacement of defecve parts with the owner paying all other costs including labor.
IV. What is not covered: Lynx shall not be responsible for and shall not pay for the following
1. Damages or problems caused by improper installaon or use;
2. Service by an unauthorized service provider;
3. Damage or repair due to service by an unauthorized service provider or use of unauthorized parts;
4. Warranty does not apply to products installed in any commercial or non-residenal applicaon. Examples of excluded applicaons
include, but are not limited to day care centers, schools, bed and breakfast centers, churches, private clubs, re staons, club
houses, common areas in mul-family dwellings, restaurants, hotels, nursing homes, food service locaons and instuonal food
service locaons.
5. To correct normal adjustments or sengs, due to improper installaon, commissioning or local supply properes;
6. Shipping and handling costs, export dues, installaon, removal, or re-installaon cost.
7. Display models are generally sold “as is.” If you have purchased a display model, please be advised that it is sold “as is” and that
it is subject to the following warranty exclusions: any exterior or cosmec damage is non warrantable; any missing components
will be re-placed at consumers expense; major handling damage will be serviced at consumer’s expense; all other warranty’s
(standard warranty) will remain in eect.
8. The cost of a service call to diagnose trouble.
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
13
|
• TGI Fridays
• Applebee’s
• Houston’s
• Red Lobster
• Hard Rock Café
• Wolfgang Puck’s
• Cheesecake Factory
• Red Robin
• Planet Hollywood
• Hilton
• Hyatt
• Four Seasons Marriott Le Meridian
• Sheraton
• Conrad International
• Bellagio
• New York New York
• MGM Grand
• Treasure Island
• Mirage
• Paris
• Venetian
• Excalibur
• Mandalay Bay
• Riviera
• Desert Inn
• Hard Rock Hotel
• Disney World
CONTACTING LYNX CUSTOMER CARE
Before calling Lynx Customer Care, please make sure you have the following information:
• Model number
• Date of purchase
• Proof of purchase by the original owner
• Serial number
The serial number can be located interior right hand wall of the vent hood, below the wiring diagram.
For warranty service, contact the Lynx Customer Care Department for an authorized service agent near you at:
(888) 289-5969
www.lynxgrills.com
Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfaction, please write, fax
or email us:
Lynx Professional Grills
7300 Flores Street
Downey, CA 90242
Service: (888) 289-5969
Tel: (562) 299-6900
Fax: (562) 299-6978
email: service@lynxgrills.com
THE LYNX STORY
Lynx began with a vision.
A small group of manufacturing engineers with over a
century of collective experience had a dream. They dared
to take their extensive commercial manufacturing know-how
and create a line of outdoor cooking products that offer
commercial elegance and performance to the consumer
market.
Lynx has taken the quality, workmanship, service
and innovation of the commercial market and
incorporated it into the Lynx Professional Grills line of
consumer and commercial products. The combination of
creative design, superior materials and exceptional
craftsmanship elevates Lynx products to a class of their
own.
Lynx original commercial products are used every day in
restaurants, hotels and theme parks across the USA:
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION14
|
LYNX SATISFIED CUSTOMERS
EXPLODED VIEW/PARTS
1
2
3
8
7
6
5
ITEM
PART NO. DESCRIP TIONQTY.
36446
1Light Bulb Socket2
2Variable Switch1
36447
33-Speed Swi tch1
36448
4Light Bar Knob2
36449
5Light Bulb 2
36450
36453
6Filte r Knob4
712" x 14" Baffle Filte r2
36452
8600 CFM Blower Module2
36451
4
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
15
|
PRODUCT DIMENSIONS
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION16
|
PRODUCT DIMENSIONS
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
17
|
PRODUCT DIMENSIONS
SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION18
|
P/N 35320
The best outdoor kitchen products come from:
Lynx Grills, Inc. 7300 Flores Street Downey, CA 90242
Service: (888)-289-5969 Fax: (562) 299-6978
www.lynxgrills.com