INSTALLATION MANUAL
ST-D600DN2812-DSHB
Super WDR, 3D DNR True Day & Night
Dome Camera with Heater & Blower

PACKAGE CONTENTS
This package contains:
One ST-D600DN2812-DSHB Super WDR dome color camera with heater and blower
One installation manual
Mounting hardware and mounting template
One side cap
Video and external OSD control cable
RS485 terminal block
Note: The ST-D600DN2812-DSHB requires a minimum 12VDC 150mA (no heater or blower)
power supply such as the ST-PS12VDC1A or ST-PS12VDC2A. The camera may also operate at
24VAC 360mA (heater and blower on).
PRODUCT DESCRIPTION
The ST-D600DN2812-HB is a professional grade, WDR (Wide Dynamic Range) day and night
color dome camera designed to provide clear images even under intense back light conditions.
The camera uses a 1/3” SONY Color Vertical Double Density CCD, provides 600TV lines of
resolution in color and 700TV lines in B&W. The ST-D600DN2812-DSHB has a 2.8mm – 12mm
lens for wide or narrow viewing. The 3 axis mount, built-in RS485 connection and on-screen
display make this camera very easy to set up. The day and night feature supports low light
illumination down to 0.0008Lux. An integrated heater and blower make this camera perfect for all
weather applications. This is a dual voltage camera that can be powered with either 12VDC or
24VAC, however, 24VAC must be applied to activate the heater function.
SPECIFICATIONS
ST-D600DN2812-DSHB
Specifications (Typical)
1/3” SONY Color Vertical Double Density CCD
600TV Lines Color, 700TV Lines B&W
Internal H/V 15.734/59.94Hz
Line Lock H/V 15.750/60Hz
Sens-Up Off 0.12Lux (15IRE), 0.2Lux (30IRE),
0.4Lux (50IRE) F1.2
Sens-Up On 0.0002Lux (15IRE), 0.0005Lux (30IRE),
0.0008Lux (50IRE) F1.2
7. Auto Electronic Shutter
Automatic Low, Middle, High, Off
Aspherical 2.8 – 12mm DC Auto Iris ICR lens
8 Windows (Polygonal, 8 Colors)

18. Operating Temperature
DC12V 150mA, AC24V 360mA (blower & heater on)
INSTALLATION AND OPERATION
CAUTION: To reduce the risk of electrical shock do not remove the cover or back of this
unit. No user serviceable parts are inside.
CAUTION: To prevent electric shocks and risk of fire hazards, do not use other than
specified power source.
1. UNPACKING and HANDLING
Each unit is shipped assembled and factory tested.
Ensure that all accessories are removed from the container before discarding packing material
2. MECHANICAL INSPECTION
Inspect the front and rear of the equipment for shipping damage. Make sure the equipment is
clean, and no connectors are broken, damaged, or loose. If equipment appears to be
damaged or defective please contact your distributor or SecurityTronix at 1-610-429-1511 for
assistance.
3. SPECIAL ATTENTION
a. The installer must comply with electrical safety standards. There must be sufficient
space between the camera’s power supply and video line and any high voltage
equipment and/or cables.
b. To help ensure the camera’s life and proper operation do not point the camera
towards the sun or strong light.
c. Do not install the camera in an environment where the temperature is above 140° F.
d. Do not install the camera near a magnetic field or a high-power motor.
e. Do not mount the camera near a radiator or heater.
f. Only use a dry cloth to clean the camera. If there is dirt that is difficult to remove wipe
gently with a mild detergent. Never use strong or abrasive detergents.
g. Using a power supply other than specified will damage the camera.
h. Only qualified installers are allowed to install, test and disassemble the camera.
i. The camera is a low voltage product. If installed outdoors proper safety and lightening
grounding are required.
This symbol is intended to alert the user to the presence of important operating and
maintenance (servicing) instructions.
This symbol is intended to alert the user to the presence of uninsulated “dangerous
voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a
risk of electrical shock.