Security Tronix HD-COAXINATORTVI ST-HDC2PTZ, HD-COAXINATORTVI ST-HDC2PTZFM Quick Start Manual

ST-HDC2PTZ
QUICK START GUIDE
www.ŶĂĐĞďƌĂŶĚƐ.com www.securitytronix.com
ST-HDC2PTZ·Quick Start Guide
Quick Start Guide
About this Manual
This Manual is applicable to HD-COAXINATORTVI Speed Dome Cameras.
This Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in this Manual is subject to change, without notice, due to firmware updates or other reasons. Please use this user manual under the guidance of professionals.
03261060707
ST-HDC2PTZ·Quick Start Guide
Regulatory Information
FCC Information
FCC compliance: This equipment has been tested and found to comply with the limits for a digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the Low Voltage Directive 2006/95/EC, the EMC Directive 2004/108/EC, the
RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated
collection point. For more information see: www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.
ST-HDC2PTZ·Quick Start Guide
Safety Instruction
These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss.
The precaution measure is divided into “Warnings” and “Cautions”
Warnings: Serious injury or death may occur if any of the warnings are neglected.
Cautions: Injury or equipment damage may occur if any of the cautions are neglected.
Warnings
All electronic operation should be in strict compliance with the electrical safety regulations, fire
prevention regulations and other related regulations in your local region.
Please use the power adapter, which is provided with the camera. The standard of the power
adapter is 24VAC10% or 12VDC10% (depending on models). The power consumption cannot be less than the required value.
Do not connect several devices to one power adapter as adapter overload may cause over-heat
or fire hazard.
Please make sure that the power has been disconnected before you wire, install or dismantle the
speed dome.
When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power
cable, and contact support for further assistance.
If the product does not work properly, please contact your dealer or the nearest service center.
Never attempt to disassemble the speed dome yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)
Cautions
Do not drop the dome or subject it to physical shock, and do not expose it to high
electromagnetic radiation. Avoid installing the equipment on surfaces subject to shock or vibration (failure to do so can cause equipment damage).
Do not place the dome in extremely hot, cold, dusty or damp locations, otherwise fire or
electrical shock may occur. The operating temperature should be -22°F ~ 149°F(outdoor speed dome) and -14°F ~ 122°F (indoor speed dome).
The indoor dome cover should be protected from rain and moisture. Exposing the equipment to direct sun light, low ventilation or a heat source such as heater or
radiator should be avoided (failure to do so could cause a fire hazzard).
Warnings Follow these safeguards to prevent serious injury or death.
Cautions Follow these precautions to prevent potential injury or material damage.
ST-HDC2PTZ·Quick Start Guide
Do not aim the speed dome at the sun or extremely bright scenes. A blooming or smear may
occur (which is not a malfunction), and affecting the longevity of sensor at the same time.
Please use the provided glove when opening up the dome cover, avoid direct contact with the
dome cover, because the acidic sweat of the fingers may erode the surface coating of the dome cover.
Please use a soft and dry cloth when cleaning inside and outside surfaces of the dome cover, do
not use alkaline detergents.
Please keep all wrappers after unpacking them for future use. In case of any failure, you will need
to return the speed dome to the factory with original packaging to prevent to damage to the camera while in transit.
For further assistance, or if you encounter any issue while using this product, please contact your
distributor or Securitytronix at: 800-688-9282 Press 3 for support, then 2 for CCTV.
ST-HDC2PTZ·Quick Start Guide
Table of Contents
1 Installation ........................................................................................................ 1
1.1 Connecting the Cables .............................................................................................................. 1
1.2 DIP Switch Settings ................................................................................................................... 2
1.2.1 5-inch Speed Dome Settings .............................................................................................. 2
1.2.2 5-inch IR & Mini IR Speed Dome Settings .......................................................................... 4
1.2.3 7-inch IR Speed Dome Settings .......................................................................................... 7
1.2.4 Mini Speed Dome Settings ................................................................................................ 9
1.3 Wiring and Installation ........................................................................................................... 11
1.3.1 Wiring .............................................................................................................................. 11
1.3.2 Installing the Bracket ....................................................................................................... 12
1.3.3 Setting the DIP Switch ..................................................................................................... 13
1.3.4 Installing the Speed Dome ............................................................................................... 13
2 In-door Mounting Applications....................................................................... 14
2.1 5-inch Speed Dome In-ceiling Mounting Applications ............................................................ 14
2.2 5-inch Speed Dome Ceiling Mounting Applications ................................................................ 16
2.2.1 Removing the Mounting Bracket ..................................................................................... 16
2.2.2 Wiring .............................................................................................................................. 17
2.2.3 Ceiling Mounting ............................................................................................................. 18
2.3 Mini Speed Dome In-ceiling Mounting Applications ............................................................... 20
2.4 Mini Speed Dome Ceiling Mounting Applications .................................................................. 22
2.4.1 Wiring .............................................................................................................................. 22
2.4.2 Ceiling Mounting ............................................................................................................. 22
3 Application and Operations ............................................................................ 24
3.1 System Application ................................................................................................................. 24
3.2 Basic Operations ..................................................................................................................... 24
3.2.1 Configuring Patrol ............................................................................................................ 25
3.2.2 Configuring Park Actions ................................................................................................. 28
4 Troubleshooting .............................................................................................. 30
4.1 Device Exceptions ................................................................................................................... 30
4.2 PTZ Control Exceptions ........................................................................................................... 30
4.3 Other Questions ..................................................................................................................... 30
ST-HDC2PTZ·Quick Start Guide
1 Installation
Before you start:
Check the package contents and make sure that the device in the package is in good condition and all the assembly parts are included.
There are several ways to install the HDC-TVI speed dome. The wall mounting is taken as an example below.
1.1 Connecting the Cables
Please turn the power off before connecting the cables.
The cable interfaces of speed dome are shown in following figure. The cables are distinguished by different colors. The labels attached on the cables are for identification.
The cables may vary according to different camera models. Please refer to the actual device.
R
E
D
A
C
2
4
V
Y
E
L
L
O
W
/
G
R
E
E
N
B
L
A
C
K
A
C
2
4
V
Y
E
L
L
O
W
R
4
8
5
-
O
R
A
N
G
E
R
4
8
5
+
VI EOD
Alarm
HD-TVI Video Output
Power Supply
VI EOD
CVBS Video Output
RS485
Figure 1-1 Cables
Table 1-1 Cables Description
Name
Description
Power Supply
24V AC/ 12V DC
HDC-TVI Video Output
HDC-TVI and coaxial video output
CVBS Video Output
SD analog video output
RS485
RS 485 control
Alarm
Alarm input and alarm output
ST-HDC2PTZ·Quick Start Guide
1.2 DIP Switch Settings
1.2.1 5-inch Speed Dome Settings
The DIP switch is used for setting the address and baudrate for the speed dome, with value ON=1 and OFF=0.
The SW1 switches from the first to the eighth are used to set the address. The SW2 switches are used to set the baudrate.
The default dome address is 0. The default baudrate is 2400.
1 2 3 4 5 6 7 8
1
2
DIP Switch
Figure 1-2 DIP Switch Settings for 5-inch Outdoor Speed Dome
1 2 3 4 5 6 7 8
1 2
DIP Switch
Figure 1-3 DIP Switch Settings for 5-inch Indoor Speed Dome
Figure 1-4 Enlarged View of DIP Switch
Address Settings
The SW1 switches from 1 to 5 are used for setting the address of speed dome. You can refer to Table 1-2 for details of setting the speed dome address to a specific number.
ST-HDC2PTZ·Quick Start Guide
Table 1-2 Set the Dome Address
Switch No.
Dome Address
1 2 3 4 5
0
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
… … … … …
31
ON
ON
ON
ON
ON
Protocol Settings
The number 6 and 7 of SW1 switches are for setting the protocol of the speed dome. You can refer to Table 1-3 for details of setting the speed dome protocol.
Table 1-3 Set the Protocol of the Dome
Switch No.
Protocol
6
7
Self-adaptive
OFF
OFF
PELCO_D
ON
OFF
MAN_BOSCH
OFF
ON
MAN_AD
ON
ON
TVI Mode Settings
The number 8 of SW1 switches is for setting the TVI mode of the speed dome. You can refer to Table 1-4 for details of TVI mode settings.
Table 1-4 Set the TVI Mode
Switch No.
TVI Mode
8
V2.0
OFF
V1.0
ON
Baudrate Settings
The number 1 and 2 SW2 switches are used for setting the baudrate of the speed dome. The baudrate can be 2400bps, 4800bps, 9600bps and 19200bps. The baudrate will be set as 2400bps by default if it is out of this range. Refer to the following table:
ST-HDC2PTZ·Quick Start Guide
Table 1-5 Set the Baudrate of the Dome
Switch No.
Baudrate
1
2
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
1.2.2 5-inch IR & Mini IR Speed Dome Settings
The DIP switch is for setting the speed dome address, baudrate, protocol, etc., with value ON=1 and OFF=0. The switch label of the 5-inch IR speed dome is on the back of the SWITCH cover as shown in Figure 1-5. The DIP switch of mini IR speed dome is shown in Figure 1-6.
DIP Switch
Screws
Switch Cover
Figure 1-5 Position of DIP Switch for 5-inch IR Speed Dome
DIP Switch Location of Mini IR Speed Dome
Screws
DIP Switch
Figure 1-6 DIP Switch of Mini IR Speed Dome
Setting DIP Switch
ST-HDC2PTZ·Quick Start Guide
1 75 6432 8 9 10
ON DIP
1 2
ON
Figure 1-7 Enlarged View of DIP Switch
For some certain models, the two individual DIP switches at the left side of the Figure 1-7 are
supported for turning on/off the terminator; while other models are not supported.
The default dome address is 0; the default baudrate is 2400; and the default value of the 120Ω
terminator is OFF.
Table 1-6 Switch Functions
Switch
Function
1 to 5
Set the address for the speed dome
6, 7
Set the baudrate for the speed dome
8
Set the protocol for the speed dome
9
Set the TVI mode for the speed dome
10
Set the terminal resistor for the speed dome
The DIP switch is designed according to binary system. When the switch is ON, it stands for the number 1. When the switch is OFF, it stands for the number 0.
Example:
The switches from No. 1 to 5 are used to set the speed dome address. No. 1 is the lowest digit and No. 5 is the highest. Turning on all these 5 switches stands for the binary number 11111. Converting the 11111 to a decimal number is 31. So the speed dome address will be 31.
Address List
For convenient settings, refer to the following list to set the address for the speed domes.
Table 1-7 Dome Address
Switch No.
Dome Address
1 2 3 4 5
0
OFF
OFF
OFF
OFF
OFF 1 ON
OFF
OFF
OFF
OFF 2 OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF … … … … … …
31
ON
ON
ON
ON
ON
ST-HDC2PTZ·Quick Start Guide
Baudrate List
For convenient settings, refer to the following list to set the baudrate for the speed dome. The baudrate will be set as 2400bps by default.
Table 1-8 Baudrate
Switch
Baudrate
6
7
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
Protocol List
For convenient settings, refer to the following list to set the protocol for the speed dome.
Table 1-9 Protocol
Protocol
8
Self-adaptive
OFF
MAN_AD
ON
TVI Mode
Table 1-10 TVI Mode
TVI Mode
9
V2.0
OFF
V1.0
ON
The speed dome is self-adaptive to private protocol when the No.8 and 9 switches are both OFF.
Terminal Resistor
Table 1-11 Terminal Resistor
Terminal Matching Resistance
10
Turn on the Resistor
ON
Turn off the Resistor
OFF
Loading...