Security Centres 808 User Manual

Page 1
808
Installation and User Guide
Compatible Equipment
927 8 character LCD keypad new style case 929 8 character LCD keypad 947 Portable printer ( Battery powered ) and power supply unit 949 Wall Mounted Printer Bracket 951 Printer lead 9040 16 Ohm internal sounder 9056 Plug-on Digital Communicator
Plug-on RedCare STU (manufactured by others)
9076-01/2 Signalling Interfaces
496336 Issue 1 1 of 22
Page 2
808
Introduction
The 808 is a programmable Alarm System suitable for domestic or small commercial premises.
The system comprises an end station in a shielded case, and up to four separate keypads. The end station provides:
Connections for up to eight Fully Supervised Loop (FSL) or Closed Circuit zones (selectable during programming).
Three outputs, two fully programmable.
Pins for fitting a plug-on communication device. Any device that complies with the Scantronic plug-on footprint can be fitted.
The installer can program the system from the keypad, which provides an eight character Liquid Crystal Display (LCD). The programming interface is arranged into a set of numbered menus that lead the installer through the installation process.
The 808 software provides a flexible installation that can meet many different needs. The system can provide for up to 8 identified users. The 808 allows users to set the system to four different security Levels (for example full set and three part sets) which can be programmed by the installer. Individual zones can be programmed as Flexi-Zones™, which change behaviour depending on which security Level is set.
The 927 LCD Keypad
Levels A to D LEDs (Set or Unset)
Power
Scroll and Level setting keys
Edit Keys
Keyboard with backlit soft rubber keys
Figure 1. 927 Operator Controls and Displays
The 927 LCD keypad provides an eight character super twist LCD display, a green Power LED, and four red Level status LEDs. The 927 also provides terminals for one zone, in addition to those supplied by the end station.
2 of 22 496336 Issue 1
8 Character Liquid Crystal Display
Optional programmable panic alarm keys. Press keys 1 and 3 together
Optional programmable control function keys. Press keys 7 and 9 together.
Menu and Enter keys
Page 3
808
Technical Specification
General
Operating temperature = -10º - +40ºC. Humidity = 80% RH. Dimensions (end station) = h x w x d 300 x 300 x 80mm. Weight (end station) = Approximately. 5Kg.
Power Supply
System Power Supply (Ambient Temp. 20 º. C) = 900 mA. With the system quiescent, this supply is used as follows: 808 end station = 90 mA. Each Remote Keypad = 60 mA. The remaining current is available for recharging the battery, and supply attached devices through the 12V Aux terminals on the main connector.
With the system in alarm the battery can supply current additional to the maximum available from the system power supply.
Output Protection
Self resetting thermal Polyswitches protect outputs at the following levels: 12V Aux =1,350mA.
Keypad 12V = 500mA. Siren = 750mA. Batt (reverse connection) = 2,500mA. Bell, Strobe and OP1 are open collector outputs rated at 500mA.
Battery
Standby Battery = 12 Volt, 6.5AH rechargeable lead-acid, Gel
Type battery.
Battery Space = h x w x d 150 x 110 x 75 mm.
Keypad Wiring
Recommended maximum distances for the remote keypads from the end station, using standard alarm cable is 100 metres per branch for the star configuration.
For a daisy chain configuration the maximum length must take account of the number of keypads sharing the cable. In general, a single keypad can be connected at the end of a maximum of 300m of standard cable. If you wish to connect more keypads the cable must be shorter, or the 0V wire must be thicker. The criterion is that at the last keypad the voltage between 0V and 12V wires must be no less than 10.5V.
496336 Issue 1 3 of 22
Page 4
Zone Wiring 808
Zone Wiring
The recommended maximum distance for FSL zones using standard alarm cable is 200m - 300m.
Software Limits
The 808 can support:
One to four Levels.
Four Areas in total.
Eight zones provided by the end station PCB plus one zone pro­vided by each keypad.
Three outputs provided by the end station PCB.
Four Flexi-Zones per Level.
8 User codes, including one Supervisor.
Keypads
Before connecting the keypad(s) to the system, the engineer must program an identification number into the NVM chip on each keypad. Each keypad in a system must have a different address number to ensure that the end station can correctly identify them. The keypad sounder, back-light and LCD display can also be tested and setup at this stage.
927 Keypad Address
1. Set the ‘Prog’ switch on the keypad PCB to ‘On’ and the ‘Test’ switch to ‘Off’.
2. Connect the 0V and +12V terminals to a 12 V DC supply, for example a charged battery.
The display shows the software number of the keypad. Take note for future reference.
3. Press ‘Enter’ twice. LED 1 lights and the display shows the current keypad address, for
example: 1- 1
4. If the display does not show the correct keypad address, enter the new address by entering a 1-digit number between 1 and 4, for example 2 for the second keypad.
The display shows the new keypad address.
4 of 22 496336 Issue 1
Page 5
808 Enabling/Disabling Keys, Display and Sounder
Enabling/Disabling Keys, Display and Sounder
5. Press ‘Enter’. LED 2 lights and the display shows the status of the keypad sounder: 0
for sounder ‘ON’ or 1 for sounder ‘OFF’, for example: 2- 0
6. Change the keypad sounder status as required by entering 0 or 1. (The keypad sounder is normally left at ON = ‘ZERO”).
7. Press ‘Enter’. LED 3 lights and the display shows the current status of the keypad
back-light: 0 for timed or 1 for back-light always ‘ON’, for example: 3- 1
8. Change the back light status as required by entering 0 or 1.
9. Press ‘Enter’. LED 4 lights and the display shows current keypad keys status: 0 for
Active or 1 for Inactive, for example: 4- 0
10. Change the keypad status as required by entering 0 or 1. (The keypad keys are normally left active = ‘ZERO’.)
11. Repeat 1 to 10 for any other keypads connected.
12. Set the ‘Prog’ switch to OFF and remove power to the keypads to lock the address and options into the keypad(s).
496336 Issue 1 5 of 22
Page 6
Wiring
The 808 main PCB has facilities for connecting:
Four keypads. Eight 2-wire FSL detector zones or eight 4-wire closed circuit zones. Siren (Loudspeakers). Three outputs.
Figure 2 shows the control unit connector.
CCT 1
Zone 1
A/T 1
A/T 2
Zone 2
CCT 2
CCT 3
Zone 3
A/T 3
A/T 4
Zone 4
CCT 4
CCT 5
Zone 5
A/T 5
A/T 6
Zone 6
CCT 6
808
CCT 7
Zone 7
A/T 7
A/T 8
Zone 8
CCT 8
0V
Keypads
Siren
Outputs
12V Aux
SRQ
Tamper return
Bell (OP1)
OP2 OP3
Sig
12V
+ve
-ve
0V
12V
+ve
-ve
Figure 2. 808 Main Connector
Wiring 927 Keypads
All keypads must be connected to Keypad terminals on the main PCB or "daisy chained" to other keypads. Figure 3 shows the connections for each keypad.
6 of 22 496336 Issue 1
Page 7
808 Wiring Detector Zones
Vol
Display
Test
SIG
SRQ
+VE
0V
Prog
FEZ
1 2
To detector
Extension Piezo 12VDC
E.E. Sounder 25mA Max.
End Station Connections
Rear of keypad pcb
N/O Exit Terminate
Button or N/C Lock Set
Switch
SIG
SRQ
+V 0V
Tamper
I/P
SND
-
+
To other keypad(s)
Figure 3. Wiring the 927 Keypad
Important: Please do not connect other devices (for example SAB, speakers and so
on) in the same cable as the remote keypad wiring.
Wiring Detector Zones
The 808 main connector has terminals for eight detector zones. Zones can be wired as either two wire Fully Supervised Loop (FSL) or four wire Closed Circuit (CC). However, all eight zones must be of the same circuit type. The factory default is for CC zones. Use Menu 21 to change between FSL or CC.
Wiring FSL zones
Each FSL zone uses a two wire closed loop, with two resistors of different values to differentiate between a ‘Circuit’ and ‘Tamper’ signals. A 2K2 (2.2 kohms) resistor is fitted in series at the end of the wired loop (EOL-End-Of­Line) and a 4K7 (4.7 kohms) resistor fitted across the alarm contact. All tamper devices are connected in ‘Series’ with the return feed to the end station, see Figure 4.
496336 Issue 1 7 of 22
Page 8
Programming 808
4k7
2k2 EOL
Note: When wiring FSL zones, link out the anti-tamper terminals of each zone in use on the main connnector and expander cards.
Alarm contacts
Tamper Loop
Zone 1
CCT
Zone 1
AT
Figure 4. Wiring Diagram for Single Alarm Contacts and Tamper Wiring
With the loop in a normal state and the alarm contacts closed (shorting out the 4K7 resistor), the total resistance of the loop is 2K2 ohms. When the alarm loop is opened and the short removed from the 4K7 resistor, the resistor is brought into the circuit and the resistance of the loop is increased to 6K9 causing the end station to detect an alarm condition. If a tamper device is opened, the loop resistance will be open circuit and the end station will detect a tamper signal.
The wiring resistance should be restricted to a maximum of 100 ohms. The recommended maximum cable distance per zone is 200 - 300 metres.
Programming
Initial Power Up
Note: Depending on the status of the system when it is powered-up, e.g., open
tampers etc., some screens may differ from those shown below.
1. Apply battery power first, then connect the mains. The keypad display shows the Software version number followed by the
date. After 3 seconds, the display shows the time: 16:07
2. Key in the factory default user code (1234) and press Enter. The display shows one of the following messages depending on how
the system is currently set up: SYS DIS RST REQ
3. Key-in the factory default installer code zero (0) + 7890, then press Menu.
The display shows: MENU NO OR LEVEL
8 of 22 496336 Issue 1
Page 9
808 Finding Menu Items
4. Press 0. The display shows: 0:INST PROG
5. Press Enter. The display prompts you to remove the end station lid: REMOVE LID
6. If the end station Tamper Switch is already open, close and open it again.
You have now reached the Installer programming mode. The display shows: 00-PROG SYSTEM
Finding Menu Items
The 808 programming is divided into sets of numbered menus. Each menu starts with a two digit number. The menus are grouped together into the following categories:
Menu No Category
00 Start point for Installer programming. 01, 04, 09 Software version, Testing, and Printing. 10, 11 Account Name. 20, 21 Zone circuit type. 31 - 32 Zone and Area Programming. 40 - 47 Level and keypad Programming. 50 - 53 Output Programming. 60 - 67 System Options. For a complete list of Menus and options see the next two pages.
496336 Issue 1 9 of 22
Page 10
Programming Chart 808
00:program system
10: Account name
11: edit name
ENTER
01:display panel version number
ENTER
Show software version
20: zone expansion
21:zone expander options
Change zone circuit type to FSL CC
ENTERENTER ENTER ENTER
04:test options
ENTER
walk test ?
TEST OUTPUTS ?
30: program zones & areas
31: zone names
32:zone options
Test outputs, speaker, sounder and keypad sounder
40: program multi-flex
41: level allocation
42: level exit mode
Allocate Areas to Levels Allocate keyzones to Levels
Allocate Exit Mode Set Exit Time
A
B
Select zone type Allocate zone to Area Select zone attribute
NOTE:
Except where shown, move between menus by using the up and down keys. At the points marked press the
ENTER
Enter key.
10 of 22 496336 Issue 1
43: level entry time
44: level flex zones
45: alarm response
46: level rearm operations
47: keypad allocations
Set Entry Time
Select Alarm Type
Assign Entry/Exit tones to keypads Enable/Disable keys 1&3 (PA) and keys 7&9 (Control)
Page 11
808 Programming Chart
A
B
09:print options
print event log?
print config
50: program outputs
51: program output type
For all types select normally energised or normally de­energised.
52: Program sounders
ENTER
ENTER
Print all, or individually: keypads, area/partitions, levels, zones, outputs, system.
60: program system options
61: installer information
62: pa response
63: line fault response
ENTER
Installer Code
Audible/Silent/Hidden
Tamper, audible, or silent
Continuous siren
53: GLOBAL bell times
Bell Run Time, Bell Delay
64: allow zone omits
65: system reset
66: PRINT OPTIONS
67: miscellaneous options
Zone omission 24hr omission
Installer reset Anticode reset
CSID code
RedCare Reset
Logging Printer
First circuit rearm or lockout Entry Abort Alarm Abort Alarm confirmation Day tamper communications Set no mains Reset no mains
496336 Issue 1 11 of 22
Page 12
Changing Menu Items 808
Changing Menu Items
After selecting a menu, press Enter to see further options belonging to that menu. The system usually displays an abbreviation for the name of the option, and the values the option currently has. A flashing character marks the part of the display that will change when you next press a key.
During programming you can select options within the menu and change their value by using the arrow keys:
Note: On the 927 keypad the A, B, C and D keys behave as arrow keys. The sticky
label provided with the keypad shows how they function during programming. Make sure you place this label in the space next to the keys under the flap of the 927.
The up and down arrow keys (A and B) normally let you select which part of the system an option will affect. For example, menus 31 and 32 use the up and down arrow keys to select particular zones or areas. Once you have selected a zone press Enter to start the zone type flashing. Use the up and down arrow keys to select the zone type. Menus 40 to 47 use the up and down arrow keys to select Areas or Levels.
The left and right arrow keys (C and D) either show more options belonging to a menu or let you move the cursor to individual param­eters that you wish to change. For example, once you have selected a zone type in Menu 32, use the right arrow key to select a zone at­tribute.
For some parameters, the up and down arrow keys also let you toggle between on or off, Y (yes) or N (no), or a short list of allowed values. For example, menu 32 uses the up and down arrow keys to switch zone attribute on or off.
When you have finished changing an option press Enter to store the change.
Correcting mistakes
If you decide you have made a mistake then you can abandon a change by pressing Menu instead of Enter. You can then re-enter the menu to key in the correct value. You can use the Menu key to escape from any part of the program.
Zone Programming
As an example of programming the system, this subsection shows you how to program an individual zone's type, area and attributes.
1. Enter programming mode if you have not already done so.
2. Select Menu 32 and press Enter.
12 of 22 496336 Issue 1
Page 13
808 Zone Programming
The display shows the zone number and current attribute. Note that the zone number is flashing (shown here by an underline). Z01-NU
To select a zone number:
3. Press the up or down arrow keys (A or B) until you see the zone number you want (in this example zone 3).
The display shows: ZO3-NU
4. Press Enter. The displays stops flashing the zone number and starts
flashing the zone type: ZO3-NU
To select the zone type:
5. Press the up or down arrow keys (A or B) until the display shows the two letter code for the zone type you want (in this example NA for Normal Alarm).
The display shows: ZO3-NA
To allocate the zone to an area:
6. Press the right arrow key (C). The display shows the current area number: Z02-NAA1
7. Press one of the number keys 1 to 4 to select the area you want the zone to belong to (in this example Area 3).
The display shows the Area number you selected: ZO2-NAA3
To allocate zone attributes:
8. Press the right arrow key (C). The display shows a letter code for the first of the
available attributes belonging to the zone type you selected earlier. (In this example the zone type was NA and the first available attribute is C (Chime).) The letter to the right of the attribute code shows whether the attribute is enabled (Y) or disabled (N). Z02-NACN
9. Press the up or down arrow keys (A or B) to enable or disable the attribute (in this example Chime is enabled.)
The display shows: Z02-NACY
10. Press the right arrow key to select the next available attribute. The display shows the next attribute available for the
selected zone type (in this example O (Omit)). Z02-NAON
11. Press the up or down arrow keys (A or B) to enable or disable the attribute.
496336 Issue 1 13 of 22
Page 14
Notes on Zone Types 808
12. Continue using the right and left arrow keys (C or D) to select attributes and the up or down arrow keys (A or B) to enable or disable them. Note that if you press the left arrow key (D) too often the display will move back to showing the zone number and type only. Simply press the right arrow key (C) until the display shows the attribute you want to change.
To store the changes you have made:
13. Press Enter. The end station stores the changes you have made and
the display shows Menu 31 (Zone Name) for the next zone (in this example zone 3) ZONE 03 Z03-NAME
Notes on Zone Types
Zone Types. You assign each detector a zone type so that the control panel
can give the appropriate response. Types include, for example, normal alarms, 24 hour alarms, fire alarms and several others.
Zone Attributes. You can further modify the way the control panel responds to each zone by assigning a zone attribute. For example, the “chime” attribute allows you to program the panel to sound a chime tone every time a particu­lar detector is triggered.
Areas. Each Area is a set of detectors in the same physical area. The 808 can use up to four Areas. You assign detectors to an area during program­ming.
Levels. A Level is a group of Areas that can be set or unset at the same time. Each Level can be thought of as a different level of security. The 808 provides up to four Levels, labelled A, B, C and D. Each Level can have its own Exit Mode, Entry and Exit Times, Alarm Response, and Re-Arm Re­sponse. LEDs on the keypads show the status of each Level.
Flexi-Zone®. A Flexi zone is a zone type that can be used whenever you want a zone to change type according to the Level of setting in use. Since an Area can belong to more than one Level, and each Level can have different entry/exit routes, then a zone with type Final Exit at one Level may need to be a Normal Alarm at another Level. You can program a Flexi-Zone to be one of the types Normal Alarm, Final Exit, Not Used or Entry Route for any Level in which it appears.
Entering Text
Some menus have options that need you to enter text, for example zone names. For those options the system lets you enter letters from the keypad one at a time by pressing a number key repeatedly until the display shows the letter you want. Each number key gives its own number and three letters of the alphabet.
14 of 22 496336 Issue 1
Page 15
808 Leaving Programming Mode
Figure 5 shows which letters belong to each number key. Select the letter you want, press the key shown the correct number of times. Use the right arrow key to move the cursor to the next space for a new letter.
If you make a mistake, use the left or right arrow keys to move the cursor over the letter you want to change, and key in the new letter. If you want to delete a name completely, use the left arrow key to move the cursor under the extreme left hand character of the name. Press the left arrow key again. The display clears the old name.
The system can store a maximum of eight characters per name, including spaces and punctuation marks.
roFniyeKroFniyeKroFniyeKroFniyeK 1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
Figure 5. Letters Generated by Each Number Key
A B C D
E
F G H
I
J
11
22
33
44
K
111
L
1111
M
N
222
O
2222
P
Q
333
R
3333
S T
444
55
555
66
666
77
777
U
4444
V
W
X
5555
Y
Z
ecapS
6666
' ( )
7777
88
888
8888
99
999
9999
00
000
0000
Leaving Programming Mode
Before returning to the ‘User Mode’, check all wiring and power connections to make sure there are no faults.
To Return to the User Mode From Programming
1. EITHER Key-in ‘00’ from any main menu heading, OR press Menu repeatedly.
The display shows: 00:PROG SYSTEM
496336 Issue 1 15 of 22
Page 16
Re-entering Programming Mode 808
2. Press Menu. If the end station lid is open, the displays shows: REPLACE LID
3. Close the end station lid. If no faults are present the display shows the
time: 09:00 If faults exist, the display will show, for example: CANT EXT
01 FLTS
REVIEW FAULTS
4. Use the up and down arrow keys to view faults present on the system. Remedy the faults, then press Menu until the display returns to the time and date.
If the display shows a "CFG ERR" (configuration error), for example: CFG ERR A IN LA
Then see "Fault Finding" for an explanation of the fault and how to correct it.
Re-entering Programming Mode
To enter Installer Programming Mode:
The display shows the time: 12:15
1. Key-in 0 (zero) followed by the Installer code (default 7890), then press Menu.
The display shows: MENU NO OR LEVEL
2. Press 0. The display shows: 0:INST PROG
3. Press Enter. The display shows REMOVE LID
4. Remove the end station lid. The display shows: 00:PROG SYSTEM
You have now reached the Installer programming mode.
Engineer Reset
If you wish to perform an Engineer Reset without removing the end station lid, type-in 0 (zero) + Engineer Code, (default 7890) then press Enter.
16 of 22 496336 Issue 1
Page 17
808 Resetting Customer and Installer Codes
Resetting Customer and Installer Codes (First stage reset)
If the installer and/or user codes have been lost, or you need to return the end station to the factory default access codes, you can load the default codes as follows:
1. Disconnect mains and battery power to the system.
2. Place a small screwdriver blade between the pins marked ‘RST’ on the main PCB.
3. Apply battery and then mains power to the end station.
4. Remove screwdriver blade from RST pins after three seconds. The system loads the factory default access codes. (1234 for User and
7890 for Installer.) All user attributes return to default values.
In addition, the system re-initialises communications with all keypads. The remaining programming is unchanged.
Return to Factory Defaults (Second stage reset)
If you need to return the end station to factory defaults (no programming and an empty log) then:
1. Follow steps 1 to 4 in ‘Resetting Customer and Installer Codes’.
2. Reset any alarms by keying-in the default User code and pressing Enter.
3. Key-in 0 (zero) followed by the default Installer code and then press Menu.
The display shows: MENU NO OR LEVEL
4. Press 0. The display shows: 0:INST PROG
5. Press Enter. The display shows: REMOVE LID
6. Open the end station tamper switch. The display shows: LOAD DEFAULTS
Note: At this point you can press Menu to abort the process of loading factory
defaults.
7. Press Enter. The display shows: SURE
Note: At this point you can press Menu to abort the process of loading factory
defaults.
496336 Issue 1 17 of 22
Page 18
Factory Defaults 808
8. Press Enter. The display shows: LOADING DEFAULTS
Followed by: 00:PROG SYSTEM The end station now has the full set of Scantronic factory defaults and
needs reprogramming.
NOTES:
1) The Bell output will be energised. If a SAB triggers at this point then check Menu 51.
2) If you remove power during programming, and you have not created a valid configuration, then the system will force you to enter programming mode when you reapply power. To make sure you can re-enter programming mode successfully the system loads the default Installer Code.
Factory Defaults
When delivered from the factory, the 808 is preprogrammed with the follow­ing default settings:
System Users
UO1: Access Code 1234, System Full Use, Zone omit Not
Permitted, Log Access = Permitted, Change Zone names = Permitted, Change Data and Time = Permitted, Reset
= Permitted User 02-08: Not Used (Duress=Disabled) User 00: Access Code = 7890
Installer programming
Menu 10: Account Name
Menu 11: Edit Name = No Name
Menu 20: Zone Type
Menu 21: Zone circuit type = CC
Menu 30: Program zones
Menu 31: Zone Names = ZO1: Zone 01 (all other zones to Zone
[nnn]) Menu 32: Zone Types = All zones Not Used (NU)
Menu 40: Program multiflex
Menu 41: Level Allocation = Level A,B,C,D = None Menu 42: Level Exit Mode = All Levels = Timed and terminate (Exit
Time = 10 Seconds) Menu 43: Level Entry Time = All Levels 20 Seconds Menu 44: Level Flexi-Zones = Not Set Up = NU Menu 45: Level Alarm response = All Levels = Full Alarm Menu 46: Level Re-Arms response = All Levels = Never Menu 47: Keypad allocation = None
18 of 22 496336 Issue 1
Page 19
808 Fault Finding
Menu 50: Program outputs
Menu 51: Output Types = Bell = Normally On, Strobe = Normally
Off, All other NO Function Menu 52: Internal sounder = Follows Bell Menu 53: Bell Delay = 0, Bell Time = 20 Minutes
Menu 60: Program System Options
Menu 61: Installer information = Code = 7890 Menu 62: PA response = Audible Menu 63: Line Fault response = Audible Menu 64: Allow Zone omits = Disabled Menu 65: System reset = Customer Menu 66: Logging Printer = Disabled Menu 67: First Circuit = Re-arm,
Alarm Abort = Disabled
Entry Abort = Disabled,
Tampers Comms = Disabled, Set
Set No AC (Mains) = Disabled, Reset No AC (Mains) =
Disabled
Alarm Confirmation = Disabled
Fault Finding
General Faults No response from the keypad keys
Check the keypad wiring.
Check the keypad address programming.
Enter and leave programming mode.
Power up while shorting RST pins.
No exit/entry tones from remote keypad
Check keypad address programming option. (See "Keypads".)
Check keypad is assigned to the Level being set (Menu 47).
Check if keypad faulty.
Configuration Checking Error Messages
The end station checks the configuration when you exit programming mode or when you apply power. If the end station finds a configuration error during power up it displays the message "CONFIG ERROR" at the keypad. The panel is unusable until you cure the problem. (Note that this will only occur if
496336 Issue 1 19 of 22
Page 20
User Facilities 808
you have removed power from the end station while in programming mode with a configuration error.)
The end station will not let you leave programming mode until you have cured a configuration error.
Note: In a configuration checking error message the display always shows the words "CFG ERR" alternating with one of the following messages:
A IN LC Meaning:Area Has No Zones. In the example shown, Level C lists an Area
which has not been assigned any zones. Action: Check Menus 32 and 41. LEVELSET O/P 12
Meaning:Levelset Output Will Not Work. In the example shown, output 12 is
a levelset output, but its assignment means that it will never work. Action: Check Menu 51. ARMING STN 2
Meaning:Too Many Levels Assigned to Arming Station. In the example
shown Keypad 2 is an arming station. You can only assign one
Level to an arming station. Action: Check Menu 47. NON KEY Z IN LA
Meaning:No Keyswitch Zone In Level. In the example shown Level A has
been assigned a keyswitch zone which is not a keyswitch zone
type. Action: Check Menu 41 or 32. KEYSWITCH ZONES
Meaning:Keyswitch Zone Assigned to Different Levels. In the example
shown a keyswitch zone has been assigned to more than one Level
in the same Partition. Action: Check Menu 41.
User Facilities
In User Mode the 808 can store unique access codes for up to eight users. Each user can be linked to one or more Levels. There are two types of user:
The Supervisor (User 01), who can change all other user's access to the system.
Ordinary users, who cannot change their level of access to user functions.
20 of 22 496336 Issue 1
Page 21
808 Operating the System
The Supervisor can give users 02 to 08 one or more of the following access rights:
Enter a Duress code.
Either Full use (set and unset the Levels they are linked to) or Arm only (set but not unset a Level).
Omit Zones.
Read the system log.
Print from the system log.
Change Zone names.
Reset Levels.
Change Time and Date.
The supervisor can give any ordinary user the access rights listed above. An ordinary user cannot change the access rights of any other user.
Operating the System
Users can set and unset the system from a keypad by one of the following methods:
[Access Code]+ [Enter Key] The system sets or unsets Level A.
Or
[Access Code] + [Level Key] The system sets or unsets the Areas as-
signed to the Level key used.
Users can reprogram limited parts of the system. The 808 provides the following set of user menus:
Menu 2: Omit 24 hour zones. Menu 3: System Options, Enable/Disable Chime. Menu 4: Test Options, including Walk Test and Bell Test. Menu 6: Set time and date. Menu 7: Change zone names. Menu 8: Change User Information (for example access
codes and authority levels). This Menu is available to User 1 only.
Menu 9: Log Functions, including View Event Log and Print
Event Log.
496336 Issue 1 21 of 22
Page 22
Installer Setting 808
To gain access to these menus from a keypad the user must key in:
[Access Code] + [Menu key] + [Menu Number]
For more information on using the 808 see "808 User Guide".
Installer Setting
When you leave Programming Mode the system will allow you to enter the Installer access code and use menus 4, 6, 7 and 9. In addition, you can also set and unset the system by entering [0] + [Installer access code] + [Enter] or [0] + [Installer access code] + [Level key].
The remote keypads display the message "System being configured" when a Level has been set using the Installer access code. Note that you cannot use the Installer access code to unset the system when a user has set the system with a user access code.
22 of 22 496336 Issue 1