QUICK START GUIDE
1 of 16
Model 27-220 (HID, SK)
Unpack box and make sure you have all items shown here.
1 2
(Screwdriver not shown.)
Edge Unit
(HID version shown)
12-V AC/DC Adapter
(PS-12DC1)
Key
3
Programming Pad
(35-030)
Carriage Bolt
( 4x )
Hex Nut
( 4x )
Unlock and open front panel of unit for
mounting, wiring, and setup.
Mount unit to pedestal using included
mounting hardware.
(This step may be completed later.)
AUTOMATIC GATES CAN CAUSE SERIOUS
ALWAYS CHECK THAT THE GATE PATH IS
REVERSING OR OTHER SAFETY DEVICES
WARNING
INJURY OR DEATH!
CLEAR BEFORE OPERATING!
SHOULD ALWAYS BE USED!
Use all four carriage bolts when mounting
Seal all openings created in the enclosure.
Failure to follow these instructions can
damage the unit and/or cause it not to
CAUTION
the unit to a pedestal.
Leave the antenna in place.
function correctly!
Continued on next page...
QUICK START GUIDE
2 of 16
Model 27-220 (HID, SK)
What’s what?
All important components labeled
Digital Input Terminals
For connecting various accessories
See Page 5
Unit shown with front panel open.
Wiring/cabling not shown for clarity.
Programming Pad
(35-030)
For programming. See Pages 8–15.
(We recommend unplugging from
circuit board and storing against
right-side wall inside Edge enclosure
when not in use.)
Wiegand Terminals
For wiring to Wiegand devices
See Page 6
Reset Button
For performing unit reset
Keypad Connector
For plugging in Programming Pad
when programming at Edge unit
© 2021 Security Brands, Inc. All rights reserved.
Power, Relay, Event Terminals
For wiring to power, wiring to
gate operator or door opener, and
connecting request-to-exit devices
See Pages 3 and 5
Relay Status LEDs
Relay is active when lit
QSG-27220-EN Rev. B (2/2021)
QUICK START GUIDE
3 of 16
Model 27-220 (HID, SK)
4
Connect wires.
Feed wires through back of unit,
and connect as shown using
included screwdriver.
Excessive force can damage unit!
Edge Power, Relay, Event Terminals
12–24 VAC/DC
POWER
J3 J17 J5
POS. (+)
NEG. (–)
RELAY A
J10
N/O
COM
N/C
RELAY B
J11
N/O
COM
EVENT INPUTS
N/C
GND
EVNT2
EVNT1
Additional wiring diagrams can
be found on Pages 5 and 6.
GND
If the included 12-V AC/DC adapter will not be
used, please go to Page 4 and follow the
procedure, Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage the unit!
CAUTION
Gate Operator / Door Opener
RADIO
COM
COM
FREE EXIT
REVERSE LOOP
POWER (+)
COM
POWER (–)
COM
OPEN
STOP
CLOSE
–
+
Third-Party 12–24-VAC/DC
Power Source
OR
Relay B can be wired to a second device in the same manner.
The GROUND terminal is optional
unless required by local code(s).
If using, please connect to earth
ground or equivalent.
12-V AC/DC Adapter
(Model PS-12DC1 included)
Consult gate/door opener
manual for exact connections.
Terminals vary widely across
manufacturers and models.
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
QUICK START GUIDE
4 of 16
Model 27-220 (HID, SK)
Using a Third-Party
Power Source (Optional)
rr
power source such as solar, verify that it
Input 12–24 VAC/DC
Current Draw less than 111 mA @ 12 VDC
4a
IMPORTANT
If you would like to use a third-party
conforms to the following specs:
no more than 10% beyond this range
less than 60 mA @ 24 VDC
Connect wires to unit as shown in
Step 4.
Before going forward, double check all
wiring and make sure the unit has power!
Wiring diagrams for connecting to accessory
devices can be found on Pages 5 and 6.
For connecting accessories not mentioned,
please contact Technical Support.
Make sure the gate or door path is clear
before completing Step 7!
Add Access Code to Relay A.
6
(To add multiple codes, enter each of them before pressing pound key.)
STOP
Master Code
(can be changed)
11 12 5
Sub Mode
Grab Programming Pad, making sure it
5
is connected to circuit board.
? ? ? ?
Access Code to Be Added
(4 digits by default; numbers only)
NOTE: The green arrow indicates a “good” tone on the Edge unit. By default, the following
codes are reserved and cannot be used: 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985.
Connect wires to your power source,
4b
positive on the Edge unit to positive on your
power source and negative on the Edge unit
© 2021 Security Brands, Inc. All rights reserved.
making sure you connect positive to
positive and negative to negative.
CAUTION
Double check that you have wired from
to negative on your power source.
Reverse polarity can damage the unit!
7
Make sure gate or door path is clear;
then enter access code on Pad, and
confirm gate or door opens.
N
INSTALLATION COMPLETE!
Jump to Page 7 to continue programming and
download the Edge Smart Keypad app.
QSG-27220-EN Rev. B (2/2021)
QUICK START GUIDE
5 of 16
Model 27-220 (HID, SK)
Event Inputs
Wiring for accessories such as a request-to-exit device
Edge Power, Relay, Event Terminals
12–24 VAC/DC
NEG. (–)
RELAY A
J10
N/O
COM
POWER
J3 J9 J5
POS. (+)
N/C
RELAY B
J11
N/O
COM
EVENT INPUTS
N/C
GND
EVNT2
GND
EVNT1
BA
Digital Inputs
Wiring to various accessories
Edge Digital Input Terminals
DIGITAL INPUTS
J8J9
#2
GND#1GND
Event Input configuration
instructions can be found
on Pages 10 and 11.
Request-to-Exit Device
(58-RTE-P is shown)
Alarm Contact
Door Switch
To Alarm
System
Digital Inputs can be
configured using the
Edge Smart Keypad app.