Security 100 KE-265 User Manual

KE-265
Keyless Entry Access Control System
Installation and Operations Manual
KE-265 Series
All rights reserved. No part of this documentation may be reproduced in any form, without prior written consent of Essex Electronics, Inc. Essex Electronics shall not be liable for errors contained in this manual. The information in this document is subject to change without notice. Essex Electronics, Inc. reserves the right to modify this documentation and to make improvements or changes to the product(s) contained in this documentation at any time.
Document Information
IOMKE265.0406.Rev D Installation/Operations Manual for KE-265, April 2006 Revision D
This documentation is applicable to the KE-265 with Rev. C on the date code label. (Located on the control module circuit board). This documentation is also applicable to prior revisions except where noted.
Trademarks
Keyless Entry® is a registered trademark of Essex Electronics, Inc. Lexan® is a registered trademark of General Electric Co., USA.
Contact Information
Essex Electronics, Incorporated 1130 Mark Avenue Carpinteria, CA 93013 (805) 684-7601 FAX (805) 684-0232
Website: keyless.com General email: essex@keyless.com Technical Support email: support@keyless.com
Copyright © 2001-2006 Essex Electronics, Inc. All rights reserved.
Table of Contents
INTRODUCTION.......................................................................................2
OVERVIEW..............................................................................................2
SYSTEM SPECIFICATIONS ........................................................................2
INPUT REQUIREMENTS.............................................................................3
OUTPUT CAPABILITIES.............................................................................3
KEYPAD OPTIONS....................................................................................4
PREPARING FOR INSTALLATION.........................................................5
SYSTEM COMPONENTS............................................................................5
THE INSTALLATION PROCEDURE........................................................6
REQUIRED TOOLS ...................................................................................6
PREPARE THE KEYPAD FOR INSTALLATION................................................6
INSTALL THE WIRING CABLE.....................................................................8
MOUNT THE KEYPAD ...............................................................................8
PREPARE THE DOOR FOR THE ELECTRIC STRIKE ......................................8
INSTALLING THE CONTROL MODULE .........................................................8
CONNECTING THE LOCKING DEVICE .........................................................9
BATTERY BACKUP...................................................................................9
SYSTEM HARDWARE SETUP..............................................................10
REMOTE BY-PASS.................................................................................10
ANTI-TAILGATING ..................................................................................10
SETTING RELAY OPTIONS......................................................................10
.....................................................................13 TAMPER ALARM LOCKOUT
....................................................................14 SYSTEM PROGRAMMING
OVERVIEW OF SYSTEM CODE PROGRAMMING.........................................14
OVERVIEW OF THE MASTER CODE .........................................................14
PROGRAMMING THE MASTER CODE .......................................................15
OVERVIEW OF USER CODES ..................................................................15
PROGRAMMING USER CODES ................................................................16
.........................................................16 PROGRAMMING DOOR OPEN TIME
............................................................................18 TROUBLESHOOTING
..................................................................20 REPAIRS AND WARRANTY
REPAIR POLICY WARRANTY
....................................................................................................25 NOTES
.....................................................................................20
...........................................................................................21
..........................................23 APPENDIX A – CIRCUIT BOARD LAYOUT
.....................................24 APPENDIX B - TYPICAL WIRING DIAGRAMS
1
Introduction
Overview
The KE-265 is an easy to program, easy to use, stand-alone Keyless Entry control requirements. Providing either a voltage output or dry contact closure, the KE-265 is designed to control any fail-safe or fail-secure electric locking device.
The KE-265 features one master code and five user codes. Two relay outputs are available to provide a variety of access control configurations including single door operation with an auxiliary output for a CCTV/Light Controller, a Gate/Garage Door controller or Doorbell activation or the KE-265 can be configured for two door operation.
System Specifications
Input Requirements: 12 to 24V AC/DC
Standby Current Draw: 12V Î 10 mA
Programmable Output:
(Door Open Time)
# of User Codes: 6 Codes (1 Master, 5 User)
Default Master Code: 1-3-5-7-9
Access Code Protection: Non-Volatile Memory
Keypad Operating
Keypad Dimensions:
5 Pad Non Illuminated
5 Pad Illuminated
Control Module Operating
Control Module Dimensions: 7½“ x 5½“ x 2½“
®
system with features suitable for basic access
24V Î 25 mA
Outputs: 2 SPDT Relay contacts at 6 amps (120VAC)
Voltage or Dry Contact Fail Safe or Fail Secure Relay Configuration 1 to 120 seconds Default Î 5 seconds
Latching: Manual (Toggle On/Off)
Code Length: 3 to 8 Digits
Tamper Alarm: 25 Incorrect Key Presses
Environment:
12-Pad 3x4
Thinline 2x6
Environment:
- 40° C to + 70° C (- 40° F to + 160° F) 100 % Relative Humidity
KP-5S, KP-5SL Î 6 ” x 2 ¼” x ½” KP-5DI, KP-5SI Î 6 ½” x 1½” x ” KP-34S, KP-34K, KP-34B Î 5 ” x 3 ” x 7/16” KP-26TS, KP-26TB, KP-26TI, KP-26TR Î 7 ⅛” x 1 ¾” x ¾”
- 40° C to + 49° C (- 40° C to + 120 ° F)
Input Requirements
The KE-265 accepts 12 to 24 volts AC/DC. An optional battery charging module and rechargeable Gel Cells are available to keep the system operational for up to 24 hours during a power interruption. System current draw (maximum):
Standby: 10mA at 12 volts, 25mA at 24 volts During Operation: .25 amps max (with illuminated Keypad)
IMPORTANT: The maximum current draw allowed is 1 amp. (3 amps with battery back-up for fail-secure applications only.) Check the specifications of your locking device. Make sure that the locking device and the KE-265 (.25 amps) combined draw less than 1 amp. For locking devices that draw more current, a separate power supply is required. (See Appendix B – Page 24)
Note: If connecting DC, make the connections to “DC IN/OUT” instead of “12-24V AC/DC IN” (see Circuit Board Layout – Page 23). Make sure the polarity is correct.
Output Capabilities
The KE-265 provides two SPDT dry contact relays (rated at 6 amps at 120 VAC). Each relay can be configured to perform one of many different functions depending on the specific access control requirement. User Authorization to control each relay is determined by Setting Relay Options (see System Hardware Setup Î page 10). Each relay can be configured for one of the following options:
1. Voltage Output – For any Fail Safe or Fail Secure Locking Device
2. Dry Contact Output – For control of Gate Operator or Garage Door
3. CCTV or Light Controller – First key press triggers a 10 second output
4. Doorbell – Press at the Keypad to trigger a 1 second output for a doorbell (not included). This function is only available with a 12 Pad 3x4 or Thinline 2x6.
5. Auxiliary Output – Momentary or Manual Control electronic device.
of an
2
3
Keypad Options
All Essex Keypads are designed to perform reliably in even the most extreme environmental conditions. Operating temperatures can range from -40°C to +70°C (-40°F to 160°F). The KE-265 is compatible with any of the following Keypad styles/configurations
KP-34S
KP-34B KP-34K
Part Number * Description
KP-5S KP-5SL KP-5DI KP-5SI KP-34S KP-34B KP-34K KP-26TS KP-26TB KP-26TI KP-26TR
* Keypad Part Number is located on the back of the Keypad
:
KP-5SI
KP-5DI
®
Illuminated Overlay
KP-5S
KP-5SL
5-Pad Stainless Steel 5-Pad Stainless Steel w/ LED 5-Pad Duranodic Illuminated 5-Pad Stainless Illuminated 12-Pad 3x4 w/ Stainless Steel Bezel 12-Pad 3x4 w/ Brass-Finished Bezel 12-Pad 3x4 w/ Black Bezel Thinline 2x6 w/ Stainless Steel Overlay Thinline 2x6 w/ Brass Overlay Thinline 2x6 w/ Black Lexan Thinline 2x6 w/ Braille Overlay
KP-26TS
KP-26TB KP-26TI KP-26TR
Preparing for Installation
System Components
There are four primary components to be installed:
1.
The Keypad should be mounted on the wall adjacent to the door. It should be on the same side as the door strike and about 4 feet above the floor.
2.
The Control Module should be mounted inside the building near a power source. Typically the control module is hidden in a false ceiling or closet. The control module must be located in an environmentally controlled area where the temperature remains between – 40°C and +49°C (-40° F and 125° F.)
3.
The Wiring Cable connects the keypad to the control module. It is important any wiring that carries line voltage. Included with the system is a 15-foot CL2 12 conductor jacketed wiring cable of which only 11 wires are used. If the Control Module must be located further than 15 feet from the Keypad, additional cable may be spliced. The maximum distance between the Keypad and the Control Module must not exceed 1,000 feet (250 feet for an Illuminated 5-Pad). For runs over 200 feet, 18 gauge wire should be used. Under 200 feet, 20 gauge is acceptable.
4.
The Electric Strike/Other Locking Device(not included) connects to the KE-265’s Main Relay output via a strike cable. (See Appendix B – Typical Wiring Diagrams. Page
24)
Typical Installation
not to locate the cable adjacent to
4
5
The Installation Procedure
Required Tools
You will need the following tools:
Medium sized, Phillips head screwdriver
1/8” standard screwdriver
Drill
Prepare the Keypad for Installation
There are different procedures for mounting each Keypad. Locate the Keypad part number on the back of the Keypad and follow appropriate mounting instructions below. Keypad templates are included with each Keypad (except KP-34’s) to assist with the installation.
Mounting Instructions 5 Pad Non Illuminated: KP-5S and KP-5SL
1. Select flat mounting surface 3" X 7".
2. Use “Template A” (included with the Keypad) to mark locations of holes A, B, and C.
3. Locate and drill the large hole marked “A”. Hole must be at least 7/8" (22mm) diameter.
4. Hold the Keypad against the wall with the connector through hole “A”. Check markings for hole “B”. Re-mark if required. If using plastic anchors, drill hole “B” using 3/16" (6mm) bit. NOTE: Plastic anchors are provided for some mounting applications. If anchors are not used, holes “B” and “C” must be smaller than 3/16".
5. Using the template, verify the hole marked “C” is aligned and then drill hole “C”.
6. Install the metal mounting bracket into hole “C” with the screw provided.
7. Do NOT mount Keypad at this time.
8. Proceed to Install the Wiring Cable.
Mounting Instructions 5 Pad Illuminated: KP-5DI and KP-5SI
1. Select a flat surface 1 ¾" X 7".
2. Use “Template B” (included with the Keypad) to mark holes A, B and C.
3. Locate and drill the large hole marked “A”. Hole must be at least 7/8" (22mm) diameter.
4. Check markings for holes “B” and “C”. Re-mark if required. Drill holes ”B” and “C” using 3/16" (6mm) bit.
5. Install the metal mounting bracket with the screws
provided.
7/8” or 1” (25mm) drill bit
1/2” (16mm) drill bit
5/32” (4mm) drill bit (For 12-Pad 3x4)
3/16” (6mm) drill bit (For 5-Pads & Thinline 2x6)
6
6. Do NOT mount Keypad at this time.
7. Proceed to Install the Wiring Cable.
Mounting Instructions 12 Pad 3x4: KP-34S, KP-34B or KP-34K
The 3x4 keypad is designed to mount to a single gang switchbox or on a wall, pedestal or any flat surface of at least 3 ½ by 5 ¼”. The composition of the mounting surface will determine the fastening method required. If mounting to a surface other than a switchbox:
1. Select a flat surface (3 ½” by 5 ¼”) near the door where you wish to install the keypad.
2. Drill the large hole for the Keypad connector using a 7/8” (25mm) drill bit.
3. Place the connector on the back of the keypad in the large hole. Mark the keypad mounting holes.
4. Drill clearance holes in accordance with fastening method used. (If mounting to wood, drill small pilot holes and use #6 flat head wood screws provided. If mounting to metal, drill two 5/32" clearance holes for #6 flat head machine screws provided.)
5. Do NOT mount the keypad at this time.
6. Proceed to Install the Wiring Cable.
Mounting Instructions Thinline 2x6: KP-26TS, KP-26TI, KP-26TB or KP-26TR
The Thinline 2x6 is designed for mullion mount applications. It can also be mounted on a wall, pedestal or any flat surface of at least 1 ¾” by 7”. The composition of the mounting surface will determine the fastening method required:
1. Select a flat surface (1 ¾ ” by 7”) near the door where you wish to install the keypad.
2. Using the Thinline template, mark location of holes.
3. Drill the large hole using a 1” (25mm) drill bit.
4. Place the connector on the back of the keypad in the large hole to verify that the mounting holes are aligned. Make adjustments if necessary.
5. Drill mounting holes in accordance with fastening method used. If mounting to wood, drill small pilot holes and use #6 flat head wood screws provided. If mounting to metal, drill two 5/32" clearance holes for #6 flat head machine screws provided.
6. Do NOT mount the keypad at this time.
7. Proceed to Install the Wiring Cable.
7