A
www.securitron.com | techsupport@securitron.com
© 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
B
C
MODEL
XMS
NOTE:ALL DIMENSIONS IN
A7B
1.75C1.875
INCHES.
EXIT DEVICE – XMS
Features
• Passive Infrared
• 12 OR 24 VDC
• Indoor use only
• Low current draw 20-50 mA depending on switching
status
• Specifically designed to reliably release magnetic locks
Operating Temperature
0 to 43C [32 to 110F]
How to Order
Part #
XMS Exit Motion Sensor
Description
Architectural Specifications
A. The Exit Motion Sensor shall be produced by an ISO 9001 certified manufacturer.
B. The exit device shall employ passive infrared detection to initiate door release and shall
operate on 12 or 24 volt DC.
C. The device shall have an adjustable detector face to allow for precise pattern
configurations, and easy pattern adjustment.
D. The exit device shall have a SP/DT relay output for shunting the alarm or access control
system and field effect transistor for direct control of an electromagnetic lock.
E. The relay shall operate 50 milliseconds before the transistor to suppress false alarms.
F. Wiring is via labeled screw terminals.