Securitron MSS-1-RT, MSS-1, MSS-1G-RT, MSS-1G, MSS-1C-RT Installtion Instruction

...
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 techsupport@securitron.com
in door opening solutions
SECURITRON MODEL MSS-1 MAXIMUM SECURITY SWITCH
INSTALLATION & OPERATING INSTRUCTIONS
1. DESCRIPTION
Securitron’s maximum security magnetic switch is intended to monitor the open or closed position of doors, windows, machinery safety barriers or other movable assemblies in critical environments where an attempt to defeat the switch is a concern. The switch includes numerous design features that make it highly defeat resistant, reduce false alarms and provide for easy and accurate installation. It is available in two versions to deal with different physical mounting conditions and may be used indoors or outdoors. Each version consists of two pieces: the switch module and the magnet pack. The MSS-1 is mainly intended for use on doors and includes a jacketed cable which can be hidden in the door frame. The MSS-1G provides a stainless steel jacketed cable which is suitable for a range of applications where the cable can not be hidden and must resist possible attack.
2. DEFEAT RESISTANCE ISSUES
The most common approach used to defeat a magnetic switch is to introduce an external magnet near the switch module so that the door, window or other barrier can be opened without the switch alarming. The MSS cannot be defeated in this way as its own magnet pack (which contains a magnet array) must be used to put it into the secure state. If a very powerful external magnet is used in an attempt to defeat the MSS, it may even put the MSS into alarm.
Another method which represents a more serious threat is when an intruder attempts to defe at the switch by obtaining a second MSS magnet pack. If access to the MSS can be obtained, the switch might be defeated by positioning the second magnet pack near the switch module in a manner that permits the door to be opened without an alarm being signaled.
The MSS design includes two defenses against this risk. The first is called co-planar operation. The switch
will only respond to the magnet pack if the pack is located in roughly the same plane as the switch. A second magnet pack placed in proximity to the switch will not activate the switch because it will be o ff-plane. In effect, there is only room for one magnet pack being read by the switch at a time, so a second pack cannot compromise security.
In certain physical situations however it may be possible to slowly open the door and slowly introduce a second magnet pack. The MSS includes an extra defense against this. The product is manufactured in different types. The magnet pack must be of the same type as the switch module to work. The MSS is delivered as a matched pair with no marking that identifies its type. Therefore, a person attempting the difficult task of trying to slowly open a barrier while introducing a second MSS magnet pack in an attempt to defeat the switch may well have the wrong type pack.
Another attack possibility is removal of the switch module. This can serve several purpose s. It can provide access to the cable (assuming the cable is hidden in the door frame). It can also be part of an attempt to remove both the switch module and the magnet pa ck as a unit to permit opening the door or window without triggering an alarm. To forestall this, the MSS includes a hidden tamper switch feature. The tamper switch provides a two wire output which is normally closed and opens if the switch is removed. This line can be separately monitored or connected in series with the main switch output. See Section 3.
Finally, a very serious threat is removal of the magnet pack from the door. If the magnet pack can be removed from the door and maintained at a correct distance from the switch module, clearly the door can be opened without signaling an alarm. The MSS’s mounting methods coupled with co-planar operation, however, preclude this. See Sections 3.2 and 3.3. To conclude, in a security application, the MSS’s array of anti-defeat features will almost always result in the alarm sounding while the switch is being tampered with. This can lead to the person attempting to defeat the switch being identified and detained.
© Copyright, 2011, all rights reserved PN# 500-16700
CO-PLANAR OPERATION
SWITCH
TO ENHANCE DEFEAT RESISTANCE, THE MAGNET PACK CAN ONLY BE READ IN A NARROW ANGLE IN FRON T OF TH E SWITCH.
MAGNET PACK
3. PHYSICAL INSTALLATION
The MSS can be used to monitor the opening of doors, windows, gates and barriers of all types. The switch module is mounted on the part of the assembly that is fixed (such as a door frame) and the magnet pack is mounted on the part of the assembly that moves (the door, for example).
Unlike many magnetic switches, the performance of the MSS is unaffected by the type of surface it’s mounted on. It will perform the same on steel as on wood.
In planning for mounting the MSS, note that the switch and the magnet pack have to be
oriented correctly, have to be roughly in the same plane and have to be a defined distance apart.
To obtain correct orientation, note the
SEPARATION DISTANC E
arrows on the labels on each component. The arrows have to directly face each other and the ends of the two pieces must be even, not offset.
The MSS includes a minimum and maximum operating distance. The unit will report secure only when the separation distance is between this maximum and minimum. If the
THE ARROWS ON THE SWITCH AND MAGNET PACK MUST FACE EACH OTHER AND AND THE ENDS OF EACH COMPONENT MUST BE EVEN- NOT OFFSET.
SEPARATION DISTANC E IS SPECIFICALLY NOTED FOR EACH INDIVIDUAL PAIR.
magnet pack is too close to the switch module or too far away, the unit will alarm.
The distance between the minimum and maximum separation points is called the gap. The MSS provides a gap of 4/10”-1/2” (10-12.5MM). For best reliability, you want to set the actual separation distance exactly midway in the gap. The gap will, however, vary somewhat on each unit and the minimum distance at which the gap starts will also vary. You can, of course determine the optimum midway separation distance by using a ruler and Ohmmeter but as part of our QC proce dure, we have checked this distance and it is printed on the switch module label. Use this separation distance when you mount the unit.
The tamper feature on the MSS works as follows. An oval h ead screw (supp lied) is set into the surface which is to receive the switch module. Two metal washers are placed under the screw head to yield the correct height. The template shows positioning of this screw. W hen the sw itch module is installed, the tamper screw depresses the tamper switch. This closes the two wire tamper circuit. Note that if you push the tamper switch in with a pa per clip for example, you’ll hear it click. This is not the switching point. Switching occurs much earlier in the travel so that the height of the screw head will always move the tamper switch past its switch point but will not bottom it out which could damage the tamper switch. Make sure, however that you place
the two metal washers under the tamper screw head and then screw it down flush with the mounting surface. This sets up the correct height of the screw head. Note also the
fact that the switch module is tampered is undetectable and any attempt to remove the switch module will open the tamper circuit. This circuit may be directly monitored (usually by a 24 hour circuit) or connected in series with the closed loop of the main switch output such that a tamper violation will create the same alarm signal as if the door was opened.
3.1 CABLE PROTECTION
The Underwriter’s Laboratories standard for high security switches requires that a cable sheathed in plastic such as the MSS-1 cable must be protected from attack by being routed through a metal frame. This is most commonly a door frame but could also be the frame of a gate or other opening. The mounting methods described in sections 3.2, 3.3 and 3.4 show in detail how this is to be accomplished. If your application is such that the cable
cannot be routed through a metal frame member and therefore fully protected, you must use model MSS-1G which includes a stainless steel protective jacket for the cable (see
section 3.5). This alternative will satisfy UL’s requirements.
PN# 500-16700 Page 2 Rev. D, 03/13
3.2 OUTSWINGING DOOR INSTALLATION
The MSS-1 version with long jacketed cable is intended for a protected and unobtrusive installation
SEPARATION
DISTANCE
CABLE
TAMPER SCREW
SWITCH MODULE
on outswinging doors. The drawing to the right shows the preferred config uration.
Start by mounting the magnet pack on the door. Note that the magnet pack has two sets of screw holes. Select the magnet pack position so that the
arrow on its label is pointing towards the switch module. As the drawing shows, the label is
on the top of the pack (facing up). Then mount the magnet pack as shown. Drill 7/64” (2.75MM)
DOOR
MAGNET PACK
HEADER
LABEL
STOP
diameter pilot holes for the #8 mounting screws. Don’t drop it below the door stop by more than 1/8” (3MM) as it must remain roughly in the same plane as the switch.
Next, mount the switch. Set the leading edge of the switch to match the separation distance printed on the label. Make sure the switch label arrow points at the magnet pack arrow and, using the template, drill 7/64” (2.75MM) diameter holes for the #8 mounting screws and a 3/8” (9.5MM) diameter hole for the cable which will be concealed in the door frame. If you are planning to use the tamper feature of the switch, drill a 3/32” (2.25 MM) diameter hole for th e #6 tamper screw, again following the template. Be sure to use the two metal washers on the tamper screw to yield the correct height. This installation technique produces an attractive and high security result. Note that with this mounting method, the magnet pack cannot be removed without opening the door which would result in an alarm event.
Some outswinging doors pose special problems. Many aluminu m fra me g lass doors have what is called a blade stop. This is typically ab out 1/8” (3MM) in wid th and obviously cann ot accept the switch. There are two solutions for this situa tion. The most professional is to cut out a se ction of the blade stop just large enough to mount the magnet pack on the door. The switch than mounts directly on to the header which also conceals the cable. An alternate method is to employ a spacer block to position the switch down far enough to clear the blade stop. The magnet pack can then mount lower on the door. This method requires pulling the cable through the spacer block up into the header and also has the disadvantage of weakening the security of the tamper switch. The tamper switch will trigger if the switch module is removed from the spacer block but not if the spacer block is removed from the header while being held tight against the switch module.
Another door problem can occur if a conventional stop is not as wide as is necessary to mount the switch (considering the set-back needed for the magnet pack and separation d istance). The back part of the switch will be hanging in space. A spacer piece can be added to the stop to widen it, but note that the switch module can be successfully mounted with only its two front screws. The cable exit has been deliberately located forward so that the cable can be concealed successfully in a narrow door stop. The tamper switch, however, may be unusable.
3.3 INSWINGING DOOR INSTALLATION
The MSS is generally mounted on the inswinging side of a door when that side represents the protected
TAMPER SCREW
SWITCH
area. The drawing to the right displays a cross section
STOP
CABLE
HEADER
LABEL
DOOR
SEPARATION DISTANCE
of this configuration. It shows the unit mounted at the top of the door but naturally the unit can also be mounted on the side.
Start by mounting the magnet pack on the door. Note that the magnet pack has two sets of screw holes. Select the magnet pack position so that the arrow on its label is pointing towards the switch module. As the drawing shows, the label is facing towards the
MAGNET PACK
door. The magnet pack should then be mounted as shown. Drill 7/64” (2.75MM) diameter pilot holes for the #8 mounting screws.
PN# 500-16700 Page 3 Rev. D, 03/13
Next, mount the switch module. Set the leading edge of the switch to match the separation distance printed on the label. Make sure the switch label arrow points at the magnet pack arrow and, using the template, drill 7/64” (2.75MM) diameter holes for the #8 mounting screws and a 3/8” (9.5MM) diameter hole for the cable which will be concealed in the door frame. If you are planning to use the tamper feature of the switch, drill a 3/32” (2.25MM) diameter hole for the #6 tamper screw, again following the template. Be sure to use the two metal washers on the tamper screw to yield the correct height. This installation technique produces an attractive and high security result. A particular benefit of an inswinging door installation is that when the door opens, it sweeps out the area under the switch. Therefore someone trying to defeat the switch with a second magnet pack would be un able to position it in the co-planar position because of movement of the door. Co-planar operation also precludes defeating the switch by removing the magnet pack. As soon as the pack is off-plane an alarm will be signaled.
4. WIRING
The MSS has five wires that are assigned by color as follows: White = Common Green = NC Orange = NO Red = Tamper NC Black = Tamper NC
Because we’re using the terms normally open and normally closed, it’s necessary to define what we mean by “normal”.
The normal condition of the MSS is when it is reporting secure (the magnet pack is at the separation distance from
the switch module). So, for example, you’ll read a closed circuit between White and Orange if you meter the switch module in alarm condition (magnet is not near the switch
GREEN
ORANGE
WHITE
RED
BLACK
NC NO
COM
TAMPER NC TAMPER NC
module) but you’ll read open if you meter it in the secure condition.
The Red and Black tamper wires will be closed when the tamper switch is in secure condition (depressed by the tamper screw) and open if the tamper switch is undisturbed
SCH EM ATI C SHOW S SW ITCH IN SECURE CONDI T ION W ITH T A MP ER FEATURE IN USE. CONTACTS WILL SWITCH WHEN SWITCH ALARMS OR TAMPER IS VIOL ATED.
(alarm condition). Separate connection of the main switch output and the tamper output requires two alarm
points. Generally, the switch output is connected to a point which is subject to arming and disarming depending on the time of day. The tamper contacts are connected to a 24 hour po int to raise an alarm any time the switch module is tampered with.
If two alarm points are not available (because of wire count limitations for example) the tamper output can be wired in series with the switch’s NC loop. With this connection (shown in the drawing to the right), the circuit will open creating an alarm condition if either the door opens or the switch
GREEN
WHITE
RED
BLACK
NC
SERIES CONN ECTIO N OF SWITCH AND TAMPER NC LOOP S TO M AIN TA IN BO TH FEATUR ES W IT H A SINGLE ALARM POINT.
COM
module is tampered with while the door is closed.
Maximum contact ratings depend on the voltage put throu gh the switch. They are 250 mA at 12V or less and 125 mA at 24V. In special applications, the switch can accept up to 100V
but the current must be proportionately limited to a maximum 3 watt power rating (60 mA at 50V; 30 mA at 100V). The tamper circuit can handle a maximum of 1 Amp.
5. MAGNACARE LIFETIME REPLACEMENT WARRANTY
For warranty information visit www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/
PATENT NOTE: The products discussed in this manual are covered under US patent #5,668,533