Securitron DC-32BK, DC-32BP, DC-32CL, DC-32SP, DC-38SP Installation Instructions

...
Page 1
Securitron Magnalock Corp. Tel 775.355.5625
550 Vista Boulevard Fax 775.355.5633
Sparks, NV 89434 info@securitron.com www.securitron.com
MAGNALOCK MODELS M32, M62 AND M82B
INSTALLATION INSTRUCTIONS
1. INTRODUCTION
The Securitron Magnalock family represents the state of the art in electromagnetic locking. There are three (3) models with operational electrical characteristics including mounting configuration options addressed in this manual.
The BondSTAT “B” Magnalock Series, Bond Sensor, monitors the magnetic field. An internal sensor activates a SPDT dry contact relay connection designed for interface to access control and/or alarm systems for reporting the status of the Magnalock. (Section 5.2.4)
The DPS “D” Magnalock Series, Door Position Sensor, is activated by a special magnetic strike armature assembly. The isolated SPDT reed switch, with an internal resettable protection device, is designed for interface to access control and/or alarm system for door status. (Section 5.2.4)
2. SPECIFICATIONS
MODEL M32 M62 M82B
Holding Force 600 Lbs [272 kg] 1200 Lbs [544 kg] 1800 Lbs [816 kg]
Dimensions: Length 8" [203mm] 8" [203mm] 12" [305mm]
Height 1.88" [48mm] 3" [76mm] 3" [76mm]
Depth 1.6" [41mm] 1.75" [44mm] 1.75" [44mm]
Dual Voltage 12/24 Volts DC
Current: @ 12 VDC 300mA 250mA 350mA
@ 24 VDC 150mA 150mA 200mA
Capacitance: @ 12 VDC 6.8 mF 44 mF 44 mF
@ 24 VDC 6.8 mF 11 mF 11 mF
BondSTAT Rating Voltage: 30 VDC (Maximum) ~ Current: 1 Amp (Maximum)
DPS Rating Voltage: 30 VDC (Maximum) ~ Current: 125 mA (Maximum)
3. PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required components and hardware have been included. Along with these instructions and the installation template, the lock assembly should include the following items:
Magnalock
Sex Bolt
Strike Plate
Hardware Pack
Figure 1
© Copyright, 2008, all rights reserved PN# 500-10420 Page 1 Rev. E, 05/08
Page 2
4. RECOMMENDED TOOLS
Power Drill Hammer Wire Strippers/Cutter 1/8”, 3/8”, 1/2” Drill Bits Center Punch Crimp Wire Connectors 1/2” Open end or Crescent Wrench Masking Tape Crimp Tool 3/16” Hex Key (Allen Wrench) Fish Tape or Lead Wire Multimeter
5. INSTALLATION INSTRUCTIONS
5.1 Pre-Installation Survey
It is recommended that an initial on sight survey be performed. A method of mounting should be determined and an installation plan should be reviewed as follows:
Physical strength of mounting areas should be strong enough to meet or exceed the holding force of the required Magnalock.
Placement of the Magnalock wiring and protection from potential damage due to intruders or vandals external attack should be considered during the survey.
Accessibility should be considered for prevention of any potential safety hazard.
Additional brackets may be needed for proper installation. Specialized brackets are available through Securitron and their many product distributors. (Section 6)
5.2 Out-Swinging Door
The installation shown below in Figure 2 illustrates the door swinging away from the Magnalock. This is a common configuration on the secure side of exit doors. The Magnalock mounts to the door frame header near the corner opposite the hinge side. The Magnalock may be mounted horizontally or vertically depending on the installation required. The brackets shown in Figure 2 are to assist installation to door frames that may need modifications to complete the installation.
Door Frame & Stop
Blind Nuts
UHB Bracket
Rubber Washers
Sex Bolt & Strike
SFP Bracket
Magnalock
Mounting Screw
Mounting Screws
Door
Flat Washers
Strike Plate
Dress Plugs
M32 ~ 2-1/4” M62 ~ 2-1/2” M82 ~ 2-1/2”
Figure 2
PN# 500-10420 Page 2 Rev. E, 05/08
Page 3
5.2.1 Mounting the Strike Plate
The strike plate should be mounted prior to the magnet in out-swinging door applications. Figure 3 below illustrates a typical strike mounting configuration.
Strike Mounting
Screw
2-3 Washers
Strike Plate
2X Roll Pins
Door Frame & Stop
Strike Bushing
2X Roll Pin Bushings
Sex Bolt
Figure 3
Select a mounting location for the Magnalock and st rike assembly as mentioned in Section 5.1. The following general guideline should be used for consideration during the installation review:
Read and follow the template instructions which include drilling and mounting instructions.
Installing a strike plate horizontally, the top edge of the strike will be approximately 1/8"
[3.2mm] below the door frame stop. If the strike and magnet are to be mounted vertically, increase this clearance between the strike and frame to 3/16" [4.8mm].
An approximated 1” [25.4mm] clearance should be considered between the Magnalock and the edge corner of the door frame. This will allow proper access for the mounting locations for drilling and tool access.
Use the template provided for positioning and marking the mounting locations of the Magnalock and strike. Check the external and internal areas of the marked door and frame for any obstacles such as wire chases or internal structural features. Make necessary adjustments to avoid these obstacles.
Offset strikes are available for lowering a strike alignment 1/4” [6.0mm] allowing clearance when door construction contains obstructions in the mounting locations.
5.2.2 Mounting the Magnet
Installations with blade stops require an Aluminum Spacer Bracket (ASB) for clea rance without having to cut the stop as shown in Figure 4. Information on mounting brackets is located in Section 6 of this manual.
To properly install the Magnalock, the following condition s sho uld be verified:
The entire Magnalock mounting area for the magnet must be a flat surface.
The frame area selected must be structurally strong enough for support.
The magnet face must be mounted parallel to the door face when closed.
The installed strike must still allow the door to close properly by clearance and alignment.
The Magnalock face and strike plate must be aligned so that they are centered.
ALIGNMENT IS IMPORTANT FOR “B” & “D” MAGNALOCKS (Se c ti o n 5.2.4)
ALIGNMENT IS CRITICAL FOR THE MAGNALOCK HOLDING FORCE (Section 2)
Mark and drill all holes for the mounting screws as instructed on the template.
Make wire connections, apply power and test for proper operation.
Mount the Magnalock using the hardware and thread locking compound provided.
Tighten the screws until secure.
DO NOT OVER-TIGHTEN SCREWS
NEVER DRILL MAGNALOCK MOUNTING HOLES
– DAMAGE MAY OCCUR –
PN# 500-10420 Page 3 Rev. E, 05/08
Page 4
Figure 4 below illustrates a typical Magnalock out-swinging door installation.
(
ASB Bracket
Not Included)
Flat Washers
Mounting
Screws
Blind Nuts
Magnalock
Mounting Hole
Dress Plugs
Figure 4
Door Frame & Stop
Blind nuts MUST be used for mounting Magnalocks to aluminum and/or hollow metal frames. These items are included with the Magnalock hardware pack.
NEVER USE SHEET METAL SCREWS TO MOUNT MAGNALOCKS
5.2.3 Blind Nut Installation
Install a blind nut into each of the 3/8” [9.5mm] hole using the blind nut collapsing tool provided. Use the following instructions and Figure 5 for the installation of the blind nuts:
Drill 3/8” [9.5mm] diameter mounting holes into the marked locations of the frame.
Insert the assembled Blind Nut and Installation Tool into a mounting hole.
Use 1/2” [13mm] box-end wrench for holding the Install Nut.
Use a 3/16” [5.0mm] Hex Wrench with the Socket Cap Screw to collapse the Blind Nut.
Remove the collapsing tool when finished.
Check that the blind nut is collapsed properly.
The collapsing tool is reusable for several blind nut installations.
Blind Nut
Install Nut
2X Flat Washers
Socket Cap Screw
Figure 5
PN# 500-10420 Page 4 Rev. E, 05/08
Page 5
5.2.4 Lock/Strike Installation for “B” and “D” Magnalocks IMPORTANT!
PLEASE READ AND APPLY THIS INFORMATION WHEN ALIGNING/INSTALLING THE
LOCK AND STRIKE. THE ALIGNMENT TOLERANCES INDICATED FOR EACH LOCK
MODEL ARE CONSIDERED CRITICAL FOR THE PROPER OPERATION OF BOTH THE
MAGNETIC BOND SENSING AND DOOR POSITION SENSING SYSTEMS!
SENSOR RANGES (PHYSICAL POSITIONING):
The BondSTAT “B” and DPS “D” Magnalock “Secure Zone” sensing ranges for each lock model is listed in Table A.
Secure Sensor Indication Range
(Dimensions from Center)
X
(-)
0
(+)
Model "X" (+/-) "Y" (+/-)
M32B/D 9/32" 1/8" M62B/D 5/16" 1/8"
(+)
0
(-)
(+)
(-)
Y
M82B/D 9/16" 1/8"
(-)
Table A
(+)
Figure 6
(The Figure 6 illustration is a visual reference to the sensing ranges outlined in Table A).
5.2.5 In-swinging Door Installation
Figure 7 below illustrates a typical in-swinging door mounting configuration. This installation
requires the use of a face mount style Ma gnalock ( i.e. M32F, M62F, or M8 2FB) and a “Z” bra cket (Z-32, Z-62, or Z-82) or an adjustable “ZA” bracket (ZA-32/62 or ZA-82) for offsetting the mounting of the strike must be used. Follow the installation instructions provided with the “Z” or “ZA” bracket product to correctly install the Magnalock in this arrangement.
THE M62F AND M82FB INCLUDE FIVE (5) MOUNTING HOLES FOR FLEXIBILITY
Blind Nuts
and Mounting
Screws
Door Frame and Stop
Sex Bolt
Z-Bracket or “ZA Bracket
(Dress cover not shown)
Strike Mounting
Hardware and
T-Nut
Strike Plate
Magnalock
Bracket Mounting
Hardware
Door
Figure 7
PN# 500-10420 Page 5 Rev. E, 05/08
Page 6
5.2.5 Single Lock - Double Door Magnalock Mounting
A single Magnalock can be used to secure double doors using a split strike plate. The part numbers reduction of holding force for each model is listed below in Table B. Use the template and instructions provided with the split strike package for proper installation. (See Section 7)
Model
M32 N/A ASS-32 230 lbs. [104 kg]
Offset Strike Part Number
Split Strike
Part Number
Holding Force
(per leaf)
M62 AOS-62 ASS-62 550 lbs. [250 kg] M82 AOS-82 ASS-82 850 lbs. [385 kg]
Table B
5.2.6 DM62 Double 62 Magnalock
The DM62 consists of two (2) Model 62 Magnalocks arranged in one (1) stainless steel housing as shown in Figure 8. This product individually secures out-swinging double door applications.
Figure 8
Use the template diagram installation instructions included with the DM62 Magnalock assembly. The features to consideration during the installation procedure:
Position the Magnalock centered between the doors.
The mounting diagram measurement and marking placement are critical.
The mounting diagram is NOT a scaled template.
Refer to the Magnalock out-swinging door mounting procedures in Section: 5.2.
Refer to the strike mounting procedures in Section: 5.2.1.
Refer to the blind nut instructions in Section: 5.2.3.
5.2.7 Mounting Magnalocks for Gates
The “G” Series Magnalock is suitable for use on outdoor gates. Figure 9 illustrates a variety of typical gate operations for application types and installation techniques. Special mounting brackets are available. See Section 6.2 for gate bracket information.
IMPORTANT
THE STRIKE PLATE SHOULD NOT BE WELDED DIRECTLY TO THE GATE
THE STRIKE MUST BE MOUNTED USING THE HARDWARE PROVIDED
HOLDING FORCE AND ALIGNMENT WILL OTHERWISE BE AFFECTED
PN# 500-10420 Page 6 Rev. E, 05/08
Page 7
GATE STYLE OPERATIONS AND INSTALLATION TECHNIQUES
Figure 9
5.3 ELECTRICAL INSTALLATION
5.3.1 General Characteristics
The Magnalock is a low current load device using specialized internal circuitry. The normal characteristic of an inductive load, such as inductive kick-back, is not present. See Section 2 for more information.
5.3.2 Electrical Standards
DC voltage, full-wave rectified, must be provided for proper operation of the Magnalocks. The red wire receives +12VDC or +24VDC, and the black wire, 0 Volts (negative). If the lock is connected with reverse polarity, it will not operate. The M32, M62 and M82B Magnalocks are auto sensing dual voltage locks. The Magnalock circuit design will au tomat ically select the p roper operational conditions for the applied voltage. See Section 2 for more information.
5.3.3 Poor Release Characteristics
The Magnalock is designed with quick release circuitry. Wiring errors may cause a Magnalocks to release slowly. Figure 10 illustrates a parallel installation of a resistive load (correct). Figure
11 illustrates a parallel reverse diode (incorrect).
Figure 10 Figure 11
5.3.4 Sensor Ranges (ELECTRICAL)
The “B” version monitoring system is also voltage sensitive. The specified voltage ranges must be properly applied. Refer to Section 2 for the recommended operating voltage ranges.
PN# 500-10420 Page 7 Rev. E, 05/08
Page 8
5.3.5 Electrical Wiring
The following diagrams, Figures 12, 13, 14 and 15 represent the proper electrical wiring connections required for Magnalock Standard, BondSTAT “B”, DPS “D” and “BD” versions.
Figure 12
Figure 13
Figure 14
Figure 15
PN# 500-10420 Page 8 Rev. E, 05/08
Page 9
5.3.6 BondSTAT Sensor status wiring description
The green and white wires supply electrical connection when the lock is ON and secure.
The orange and white wires supply electrical connection when the lock OFF or unsecure.
5.3.7 DPS – Door Position Sensor status wiring description
The blue and yellow wires supply electrical connection when the door condition is closed.
The brown and yellow wires supply electrical connection when the door condition is open.
5.3.8 Double Door Status Wiring – BondSTAT
When two Magnalocks are used for double door installation the BondSTAT contacts should be wired in series for proper reporting. Connect the green wire of one lock to the white wire of the other as shown below in Figure 16.
Figure 16
5.3.9 Double Door Status Wiring – DPS
When two Magnalocks are used for double door installation the DPS contacts should be wired in series for proper reporting. Connect the blue wire of on e lock to the yellow wire of the other as shown below in Figure 17.
Figure 17
5.3.10 Emergency Release
Magnalocks are often wired into a system for quick release in case of emergency. Manual switching or automatic triggering from a fire alarm system is practical. It is the user's responsibility to correctly hookup the Magnalock according to the instructions. It is recommended to use a switch or relay to perform break of power. Securitron power supplies have terminals for the interconnection of such emergency release switches.
THE END USER & INSTALLER ARE LIABLE FOR FIRE & BUILDING CODES COMPLIANCE
6. SPECIALIZED MOUNTING BRACKETS
ASB – Aluminum Shim Bracket – The ASB bracket is designed for 1/2” [12.7mm] blade stop and/or weather trim clearance mounting of Magnalocks on aluminum frame glass doors.
CWB – Concrete/Wood Header Bracket – The CWB bracket is designed for mounting Magnalocks on concrete filled and/or wood headers.
FMK-SL & FMK-SW – FLEX-MOUNT Kit – The FMK (FLEX-MOUNT) bracket kits are designed to install on most gate applications. Adapts to round or square posts from 1” [25.4mm] to 3” [76.2mm]. The FMK-SL is designed for slide gate type applications. The FMK-SW is designed for swing gate type applications.
GDB – Glass Door Bracket – The GDB bracket is designed for mounting a Model 32 or Model 62 strike to solid-type framed and unframed glass doors. An AKG ad hesive kit used for bonding.
HEB Bracket – The HEB is a 90 degree bracket designed to extend the door stop and create a flat surface for mounting the Magnalock.
HEB-3G Bracket – The HEB-3G bracket is a 90 degree bracket designed for mounting to solid-type framed and unframed glass headers. An AKG adhesive kit used for bonding.
PN# 500-10420 Page 9 Rev. E, 05/08
Page 10
SFP – Stop Filler Plate – The SFP bracket is designed for extending the door frame mounting surface 1-1/4” [31.8mm]. Thicknesses available in 1/4” [6.4mm], 3/8” [9.5mm], 1/2” [12.7mm] and 5/8” [15.9mm]. Lengths available in 8” [20 3mm] for M32 or M62 and 12” [305mm] for M82B Magnalocks.
UHB – Universal Header Bracket – The UHB bracket is designed to extend the frame width 1” [25.4mm] to 1-1/2” [38.1mm] deeper on steel and aluminum headers not wide enough to mount the Magnalock. Lengths available in 8” [203mm] for M32 or M62 and 12” [305mm] for M82B Magnalocks.
Z-Bracket – The “Z” bracket is designed for use with installations of “F” Series Magnalocks for in-swinging doors and gates.
ZA-Bracket – The “ZA” bracket is designed to allo w a full range of adjustability for use with installations of “F” Series Magnalocks for in-swinging doors and gates.
7. SPECIALIZED STRIKES
The AOS – Armature Offset strike is designed for offset drilling doors with mechanical interference hardware present in the door structure. It is also accommodates errors that may have occurred in the field from incorrect mounting placement. (See Section 5.2.5)
The ASS – Armature Split strike is designed for single lock/double door in stallation. There is a reduced holding force when using the split strike. (See Section 5.2.5)
8. SPECIALIZED ACCESSORIES
8.1 Dress Covers
Single Magnalock Dress Covers – The covers are designed to meet architectural finishes for matching specified installations. Available in four (4) architectural finishes.
Double Dress Covers – The covers are designed to fit over a double door/dual lock installation. Available in two (2) architectural finishes.
8.2 Installation Tool Kit Securitron offers an installation tool kit which includes special drill bits, a heavy duty drill guide, a blind nut collapsing tool, e xtra fasteners and hardware. Metric is also available.
8.3 Tamper Proofing Special tamper proof screws are available for Magnalock and strike armature mounting. The screws are pinned-socket hex head. A special hex wrench is required and is available when purchasing the screws.
9. MAGNALOCK MAINTENANCE
9.1 Visual Inspection
Check the rubber washers for elasticity and proper pivoting. Tighten as required.
Check for build-up of debris on the Magnalock and strike armature. Clean as required.
Check for rust on the Magnalock and strike plate armature. Clean as required.
9.2 Cleaning Methods
Cleaning once a year is recommended.
Clean every six months where minor rusting occurs.
Clean every three months if rust conditions are severe.
Use a plastic dishwashing scrub pad to aid in the removal of rust.
DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING
DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER
9.2.1 Indoor Applications
Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and strike plate armature.
9.2.2 Outdoor Applications
Apply a silicone based cleaner/lubricant onto a clean cloth and thoroughly wipe down Magnalock and strike plate armature. Example: Super Lube® Aerosol with SYNCOLON® (PTFE)
Part No.: 31040 ~ 6oz. / 31110 ~ 11 oz. / 32015 ~ 14 oz. Phone: (631) 567-5300 / Website: www.super-lube.com
PN# 500-10420 Page 10 Rev. E, 05/08
Page 11
APPENDIX A Troubleshooting
Problem Lock Does Not Generate a Magnetic Field Points of Reference
Check for specified voltage at Magnalock
Section 2
Solution
Check for specified current draw at Magnalock Section 2
Problem Reduced Holding Force Points of Reference
Check DC power source is Full-Wave Rectified
(Half-wave Rectifier or AC Power unacceptable)
Check for specified voltage at Magnalock
Section 2
Section 5.3.2
Solution
Check for specified current draw at Magnalock Section 2
Check strike mounting for proper installation Section 5.2.1 and 5.2.5
Check the Magnalock and strike for obstructions
and that contact surfaces are properly cleaned
Section 8
Problem BondSTAT Does Not Report Secure Points of Reference
Check for specified voltage at Magnalock
Section 2
Check for specified current draw at Magnalock Section 2
Solution
Check strike mounting for proper alignment and
pivoting for proper closure to Magnalock
Check the Magnalock and strike for obstructions
and that contact surfaces are properly cleaned
Table A / Section 5.2.4
Section 8
Problem DPS Does Not Report Door Status Points of Reference
Check strike mounting for proper alignment Table A / Section 5.2.4
Solution
Check for proper door closure
Check for proper voltage/current on switch
Check resettable protection device
Section 8.1
Section 2 Section 1
Problem The Magnalock Does Not Release Points of Reference
Make sure no voltage is present at Magnalock Section 2
Solution
Make sure the Magnalock is not drawing current Section 2
Check if the strike is sticky and hard to release Section 8
Check the Magnalock and strike for obstructions
and that contact surfaces are properly cleaned
Section 8
Problem The Magnalock is Dirty or Rusty Points of Reference Solution
Problem
Improper cleaning – Maintenance Equipment Section 8
Electronic Noise Interference with
Access Control System
Points of Reference
Solution
Check for voltage from Magnalock to door frame.
There should be no voltage present.
Section 2
IF PROBLEMS PERSIST CALL SECURITRON TOLL FREE
(800) MAG-LOCK
(800) 624-5625
PN# 500-10420 Page 11 Rev. E, 05/08
Page 12
Appendix B
Wire Gauge Factoring
1.1 Remote Power Supply
The Magnalock requires adequate voltage and current for proper operation.
Resistance is created by the length and gauge (size) of the wire being used.
An accurate estimated distance from the power supply to the opening is crucial.
For superior operation the correct size gauge wire must be used.
The devices used operate the best with the least amount of resistance on the source.
Using the correct gauge wires protects against large voltage and current (load) losses.
The gauge is determined by the wire distance, voltage and current of all devices.
1.2 Determining Wire Gauge
Follow Example A (12VDC system) and Example B (24VDC system) below.
Use Tables 1 and Table 2 to choose the corr ect wire gauge for the application.
1.2.1 Example A: (12VDC system)
Devices Used Amps (12VDC) Progressive Totals
M62 Magnalock 0.250 0.250
DK-26 Access 0.160 0.410
XMS Motion 0.050 0.460 EEB2 Timer 0.025 0.485
Total Current Rounded Up (Table 1)
Using Table 1 (12VDC) Find: - Current Draw .600 Amps
Solution: 18 Gauge is indicated for proper installation
1.2.2 Example B: (24VDC system)
Devices Used 24VDC Amps Progressive Totals
M82 Magnalock 0.200 0.200
TSB Touch Bar 0.025 0.225
DK-11 Access 0.070 0.295
XDT-24 Delay 0.050 0.345
MK Bypass/Reset 0.020 0.365
Total Current Rounded Up (Table 2)
Using Table 2 (24VDC) Find: - Current Draw .400 Amps
Solution: 14 Gauge is indicated for proper installation
0.600A
- Wire Distance 200 Feet (One-Way)
0.400A
- Wire Distance 1000 Feet (One-Way)
PN# 500-10420 Page 12 Rev. E, 05/08
Page 13
TO SOLVE: INTERSECT ROW (Current) and INTERSECTING COLUMN (Wire Distance)
1.00A
.800A
C U
.600A
R R E
.400A
N T
.300A
.200A
12VDC
20
Gauge
22
Gauge
22
Gauge
22
Gauge
24
Gauge
24
Gauge
50’
[15m]
18
Gauge
18
Gauge
20
Gauge
22
Gauge
22
Gauge
22
Gauge
100’
[30m]
16
Gauge
18
Gauge
18
Gauge
20
Gauge
22
Gauge
22
Gauge
150’
[46m]
14
Gauge
16
Gauge
18
Gauge
18
Gauge
20
Gauge
22
Gauge
200’
[61m]
Table 1
14
Gauge
14
Gauge
16
Gauge
18
Gauge
18
Gauge
20
Gauge
300’
[91m]
12
Gauge
12
Gauge
14
Gauge
16
Gauge
18
Gauge
18
Gauge
400’
[122m]
WIRE DISTANCE
10
Gauge
10
Gauge
14
Gauge
14
Gauge
16
Gauge
18
Gauge
500’
[152m]
10
Gauge 8 Gauge
10
Gauge 8 Gauge
12
Gauge
14
Gauge
14
Gauge
16
Gauge
750’
[229m]
10
Gauge
12
Gauge
14
Gauge
14
Gauge
1000’
[305m]
1.0A
.800A
22
Gauge
22
Gauge
20
Gauge
22
Gauge
20
Gauge
20
Gauge
18
Gauge
18
Gauge
16
Gauge
18
Gauge
14
Gauge
16
Gauge
14
Gauge
14
Gauge
12
Gauge
14
Gauge
10
Gauge
12
Gauge
C U R
.600A
24
Gauge
22
Gauge
22
Gauge
20
Gauge
18
Gauge
18
Gauge
16
Gauge
14
Gauge
14
Gauge
R
E N
.400A
24
Gauge
22
Gauge
22
Gauge
22
Gauge
20
Gauge
18
Gauge
18
Gauge
16
Gauge
14
Gauge
T
.300A
.200A
24VDC
24
Gauge
24
Gauge
50’
[15m]
24
Gauge
24
Gauge
100’
[30m]
22
Gauge
24
Gauge
150’
[46m]
22
Gauge
22
Gauge
200’
[61m]
22
Gauge
22
Gauge
300’
[91m]
20
Gauge
22
Gauge
400’
[122m]
20
Gauge
20
Gauge
500’
[152m]
18
Gauge
20
Gauge
750’
[229m]
16
Gauge
18
Gauge
1000’
[305m]
WIRE DISTANCE
Table 2
The Wire Distance indicated on the table above represents a 2-wire “One-Way”
length from the power supply source to entryway installation area.
The Gauge values specified on the table above represent a 2-wire “Round Trip”
length from the power supply source to entryway installation and retur ning back to the power supply source.
IMPORTANT
THE 200’ [61m] WIRE RUN IN EACH TABLE FACTORS A 400’ [122m] ROUND TRIP
PN# 500-10420 Page 13 Rev. E, 05/08
Page 14
®
MAGNACARE
LIMITED LIFETIME WARRANTY
SECURITRON MAGNALOCK CORPORATION warrants that it will replace at customer’s request, at any time for any reason, products manufactured and branded by SECURITRON.
SECURITRON will use its best efforts to ship a replacement product by next day air freight at no cost to the customer within 24 hours of SECURITRON’s receipt of the product from customer. If the customer has an account with SECURITRON or a valid credit card, the customer may order an advance replacement product, whereby SECURITRON will charge the customer’s account for the price of the product plus next day air freight, and will credit back to the customer the full amount of the charge, including outbound freight, upon SECURITRON’s receipt of the original product from the customer.
SECURITRON’s sole and exclusive liability, and customer’s sole remedy, is limited to the replacement of the SECURITRON product when delivered to SECURITRON’s facility (freight and insurance charges prepaid by customer). The replacement, at SECURITRON’s sole option, may be the identical item or a newer unit which serves as a functional replacement. In the event that the product type has become obsolete in SE CURITRON’s product line, this MAGNACARE warranty will not apply. This MAGNACARE warranty also does not apply to custom, built to order, or non-catalog items, items made by others (such as batteries), returns for payment, distributor stock reductions, returns seeking replacement with anything other than the identical product, or products installed outside of the United States or Canada. This MAGNACARE warranty also does not apply to removal or installation costs.
SECURITRON will not be liable to the purchaser, the customer or anyon e else for incidental or consequential damages arising from any defect in, or malfunction of, its products. SECURITRON does not assume any responsibility for damage or injury to perso n or property due to improper care, storage, handling, abuse, misuse, or an act of God.
EXCEPT AS STATED ABOVE, SECURITRON MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING WITHOUT LIMITATION THE CONDITION OF ITS PRODUCTS, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
PATENTS
The Securitron Magnalock is listed under U.S. patent #4,516,114 and 4,682,801.
Additional patents pending.
PN# 500-10420 Page 14 Rev. E, 05/08
Page 15
PN# 500-10420 Page 15 Rev. E, 05/08
Page 16
Why choose a genuine Magnalock ?
The Securitron Advantages...
Electrical Advantages
• Low Current Consumption (125mA-350mA) Less Heat for Longer Product Life Smaller Gauge Wire Longer Wire Runs Smaller Power Source Job Cost Savings Double/Triple the Battery Back-up Time for a Secure Facility
• Patented “State of the Art” Electronic Circuitry Instant Release Circuit “50 Milliseconds” No Inductive Kickback No Welded Switch Contacts Built-in Noise Suppression No Interference with Sensitive Electronics
• Smart Auto Switching Dual Voltage No Jumpers, No Switches, No Errors
Sealed and Weatherproof
• Securitron Magnetic Locks are 100% Plated & Sealed (excludes M38 & M68 series) Outdoor Installation; Gates, Pool Areas, and Marina Stainless Steel lock casing will not rust Operating Temperature: -40F to +140F [-40C to +60C]
• Optional Universal Conduit Fitting (M62 & M82) Secures and Conceals Magnetic Lock cable Increases the Integrity of the Lock
Mounting Hardware, Brackets and Tools
• Aerospace Collapsing Blind Nuts 1000 lbs tensile strength per blind nut
• Grade One Machine Screws 1/4-20 Allows use of “Thread Locker” adhesive
• Complete Line of Mounting Hardware for Doors & Frames Herculite, glass, aluminum, metal clad, and wood
• Optional Installation Kit A real “Tools of the Trade” kit that reduces installation error and speeds
installation time - increasing profits
• M38 & M68 Integrated mounting bracket and built-in wire access chamber Fast, easy and fool-proof installation
You don’t become the best selling or best warrantied products in the industry without a few firsts.
ST
1
“E” profile electromagnetic lock
ST
1
sealed & weatherproof electromagnetic lock
1ST electromagnetic lock that suppresses inductive kickback and electronic noise and provides instant release
1ST electric lock to mount in a standard door strike opening without cutting the frame (UnLatch) 1ST manufacturer in the security industry to offer a “no strings attached” lifetime replacement
warranty (MagnaCare)
ST
1
electromagnetic lock manufacturer to achieve ISO 9001 certification
PN# 500-10420
Page 16 Rev. E, 05/08