INSTALLATION INSTRUCTIONS
1. INTRODUCTION
The Securitron Magnalock family represents the state of the art in electromagnetic locking. There are three (3) models with operational electrical characteristics including mounting configuration options addressed in this manual.
The BondSTAT “B” Magnalock Series, Bond Sensor, monitors the magnetic field. An internal sensor activates a SPDT dry contact relay connection designed for interface to access control and/or alarm systems for reporting the status of the Magnalock. (Section 5.2.4)
The DPS “D” Magnalock Series, Door Position Sensor, is activated by a special magnetic strike armature assembly. The isolated SPDT reed switch, with an internal resettable protection device, is designed for interface to access control and/or alarm system for door status. (Section 5.2.4)
2. SPECIFICATIONS
MODEL M32 M62 M82B
Holding Force 600 Lbs [272 kg] 1200 Lbs [544 kg] 1800 Lbs [816 kg]
Dimensions: Length 8" [203mm] 8" [203mm] 12" [305mm]
Height 1.88" [48mm] 3" [76mm] 3" [76mm]
Depth 1.6" [41mm] 1.75" [44mm] 1.75" [44mm]
Dual Voltage 12/24 Volts DC
Current: @ 12 VDC 300mA 250mA 350mA
@ 24 VDC 150mA 150mA 200mA
Capacitance: @ 12 VDC 6.8 mF 44 mF 44 mF
@ 24 VDC 6.8 mF 11 mF 11 mF
BondSTAT Rating Voltage: 30 VDC (Maximum) ~ Current: 1 Amp (Maximum)
DPS Rating Voltage: 30 VDC (Maximum) ~ Current: 125 mA (Maximum)
3. PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required components and hardware have been included. Along with these instructions and the installation template, the lock assembly should include the following items:
Magnalock
Sex Bolt
Strike Plate
Hardware Pack
Figure 1
© Copyright, 2008, all rights reserved PN# 500-10420 Page 1 Rev. E, 05/08
4. RECOMMENDED TOOLS
Power Drill Hammer Wire Strippers/Cutter 1/8”, 3/8”, 1/2” Drill Bits Center Punch Crimp Wire Connectors 1/2” Open end or Crescent Wrench Masking Tape Crimp Tool 3/16” Hex Key (Allen Wrench) Fish Tape or Lead Wire Multimeter
5. INSTALLATION INSTRUCTIONS
5.1 Pre-Installation Survey
It is recommended that an initial on sight survey be performed. A method of mounting should be determined and an installation plan should be reviewed as follows:
Physical strength of mounting areas should be strong enough to meet or exceed the holding force of the required Magnalock.
Placement of the Magnalock wiring and protection from potential damage due to intruders or vandals external attack should be considered during the survey.
Accessibility should be considered for prevention of any potential safety hazard.
Additional brackets may be needed for proper installation. Specialized brackets are available through Securitron and their many product distributors. (Section 6)
5.2 Out-Swinging Door
The installation shown below in Figure 2 illustrates the door swinging away from the Magnalock. This is a common configuration on the secure side of exit doors. The Magnalock mounts to the door frame header near the corner opposite the hinge side. The Magnalock may be mounted horizontally or vertically depending on the installation required. The brackets shown in Figure 2 are to assist installation to door frames that may need modifications to complete the installation.
Door Frame & Stop
Blind Nuts
UHB Bracket
Rubber Washers
Sex Bolt & Strike
SFP Bracket
Magnalock
Mounting Screw
Mounting Screws
Door
Flat Washers
Strike Plate
Dress Plugs
M32 ~ 2-1/4” M62 ~ 2-1/2” M82 ~ 2-1/2”
Figure 2
PN# 500-10420 Page 2 Rev. E, 05/08
5.2.1 Mounting the Strike Plate
The strike plate should be mounted prior to the magnet in out-swinging door applications. Figure 3 below illustrates a typical strike mounting configuration.
Strike Mounting
Screw
2-3 Washers
Strike Plate
2X Roll Pins
Door Frame & Stop
Strike Bushing
2X Roll Pin Bushings
Sex Bolt
Figure 3
Select a mounting location for the Magnalock and st rike assembly as mentioned in Section 5.1. The following general guideline should be used for consideration during the installation review:
Read and follow the template instructions which include drilling and mounting instructions.
Installing a strike plate horizontally, the top edge of the strike will be approximately 1/8"
[3.2mm] below the door frame stop. If the strike and magnet are to be mounted vertically, increase this clearance between the strike and frame to 3/16" [4.8mm].
An approximated 1” [25.4mm] clearance should be considered between the Magnalock and the edge corner of the door frame. This will allow proper access for the mounting locations for drilling and tool access.
Use the template provided for positioning and marking the mounting locations of the Magnalock and strike. Check the external and internal areas of the marked door and frame for any obstacles such as wire chases or internal structural features. Make necessary adjustments to avoid these obstacles.
Offset strikes are available for lowering a strike alignment 1/4” [6.0mm] allowing clearance when door construction contains obstructions in the mounting locations.
5.2.2 Mounting the Magnet
Installations with blade stops require an Aluminum Spacer Bracket (ASB) for clea rance without having to cut the stop as shown in Figure 4. Information on mounting brackets is located in Section 6 of this manual.
To properly install the Magnalock, the following condition s sho uld be verified:
The entire Magnalock mounting area for the magnet must be a flat surface.
The frame area selected must be structurally strong enough for support.
The magnet face must be mounted parallel to the door face when closed.
The installed strike must still allow the door to close properly by clearance and alignment.
The Magnalock face and strike plate must be aligned so that they are centered.
ALIGNMENT IS IMPORTANT FOR “B” & “D” MAGNALOCKS (Se c ti o n 5.2.4)
ALIGNMENT IS CRITICAL FOR THE MAGNALOCK HOLDING FORCE (Section 2)
Mark and drill all holes for the mounting screws as instructed on the template.
Make wire connections, apply power and test for proper operation.
Mount the Magnalock using the hardware and thread locking compound provided.
Tighten the screws until secure.
DO NOT OVER-TIGHTEN SCREWS
NEVER DRILL MAGNALOCK MOUNTING HOLES
– DAMAGE MAY OCCUR –
PN# 500-10420 Page 3 Rev. E, 05/08
Figure 4 below illustrates a typical Magnalock out-swinging door installation.
(
ASB Bracket
Not Included)
Flat Washers
Mounting
Screws
Blind Nuts
Magnalock
Mounting Hole
Dress Plugs
Figure 4
Door Frame & Stop
Blind nuts MUST be used for mounting Magnalocks to aluminum and/or hollow metal frames. These items are included with the Magnalock hardware pack.
NEVER USE SHEET METAL SCREWS TO MOUNT MAGNALOCKS
5.2.3 Blind Nut Installation
Install a blind nut into each of the 3/8” [9.5mm] hole using the blind nut collapsing tool provided. Use the following instructions and Figure 5 for the installation of the blind nuts:
Drill 3/8” [9.5mm] diameter mounting holes into the marked locations of the frame.
Insert the assembled Blind Nut and Installation Tool into a mounting hole.
Use 1/2” [13mm] box-end wrench for holding the Install Nut.
Use a 3/16” [5.0mm] Hex Wrench with the Socket Cap Screw to collapse the Blind Nut.
Remove the collapsing tool when finished.
Check that the blind nut is collapsed properly.
The collapsing tool is reusable for several blind nut installations.
Blind Nut
Install Nut
2X Flat Washers
Socket Cap Screw
Figure 5
PN# 500-10420 Page 4 Rev. E, 05/08
5.2.4 Lock/Strike Installation for “B” and “D” Magnalocks IMPORTANT!
PLEASE READ AND APPLY THIS INFORMATION WHEN ALIGNING/INSTALLING THE
LOCK AND STRIKE. THE ALIGNMENT TOLERANCES INDICATED FOR EACH LOCK
MODEL ARE CONSIDERED CRITICAL FOR THE PROPER OPERATION OF BOTH THE
MAGNETIC BOND SENSING AND DOOR POSITION SENSING SYSTEMS!
SENSOR RANGES (PHYSICAL POSITIONING):
The BondSTAT “B” and DPS “D” Magnalock “Secure Zone” sensing ranges for each lock model is listed in Table A.
Secure Sensor Indication Range
(Dimensions from Center)
X
(-)
0
(+)
Model "X" (+/-) "Y" (+/-)
M32B/D 9/32" 1/8" M62B/D 5/16" 1/8"
(+)
0
(-)
(+)
(-)
Y
M82B/D 9/16" 1/8"
(-)
Table A
(+)
Figure 6
(The Figure 6 illustration is a visual reference to the sensing ranges outlined in Table A).
5.2.5 In-swinging Door Installation
Figure 7 below illustrates a typical in-swinging door mounting configuration. This installation
requires the use of a face mount style Ma gnalock ( i.e. M32F, M62F, or M8 2FB) and a “Z” bra cket (Z-32, Z-62, or Z-82) or an adjustable “ZA” bracket (ZA-32/62 or ZA-82) for offsetting the mounting of the strike must be used. Follow the installation instructions provided with the “Z” or “ZA” bracket product to correctly install the Magnalock in this arrangement.
THE M62F AND M82FB INCLUDE FIVE (5) MOUNTING HOLES FOR FLEXIBILITY
Blind Nuts
and Mounting
Screws
Door Frame and Stop
Sex Bolt
Z-Bracket or “ZA Bracket
(Dress cover not shown)
Strike Mounting
Hardware and
T-Nut
Strike Plate
Magnalock
Bracket Mounting
Hardware
Door
Figure 7
PN# 500-10420 Page 5 Rev. E, 05/08
Loading...
+ 11 hidden pages