• MagnaCare Lifetime Replacement No Fault Warranty
• Clean, steady, accurate power output for best performance of access control equipment
• Compact modules for smaller footprint
• Universal transformer compatible with most international power
• Works in AC brownout down to 60 VAC
• Faster battery recharging under full load
• Automatic low-battery disconnect prevents deep discharge, maintains battery life
• Self-resetting circuit breakers for common conditions including:
o Overcurrent
o Thermal runaway
o Reverse battery hookup
• Fuse protected against surge for AC input and DC output
• Auto-sensing variable speed smart fan
• Power module has ON/OFF switch to disconnect DC output fro m power
• Eight (8) channel power distribution with Access Control
o Channels individually configurable to enable/disable with fire trigger
o Heavy duty relay per output with status LED, or group outputs by jumper
o Can provide dry contacts, Normally Open/Normally Closed selected via jumper
o Individual input for each output
o Power-limited, fuse-protected outputs, each with a green status LED indicator
o Main power LED indicates input power status
o Trigger LED indicates Fire Relay status
o Pluggable terminal b locks by channel and func t io n
• SPDT Form C output for remote monitoring of trouble: AC failure, Low battery, or over
voltage
• Made in USA
Power Supply
The AQU244-8F8R power supply with battery
charger/backup and supervision is a single voltage
power supply that uses any AC power source from
90-240VAC/47-63Hz to provide up to 4 Amps @ 12VDC
continuous output.

SPECIFICATIONS: AQU244-8F8R
*Use gauge appropriate for output voltage and wiring distance.
Input Voltage Operating Range
90-240VAC
47-63Hz
Maximum Output Voltage
120 VA
5 Amps @ 12VDC
Continuous Output Voltage
96 VA
4 Amps @ 12VDC
Voltage Range
9.8 – 13.67VDC/ 13.65 typical
Operating Fr e quency
23KHz
Onboard Power Output
One (1) Output with ON/OFF switch
Max board power use: 208mA
Maximum Output Per Channel
8 channels @ .5A/channel
Fuses
Size: 050 Standard 3AGC
Output: .5A
Relays
Input Relays: 20ma required for activation
Output Relays: contacts rated 7A 125VAC max
Triggers
EOL: +/-60% of 2.2K ohms
Fuse Protection
Battery: 4 Amp
Current Overload: Fuse, self-resetting
Thermal Runaway: Fuse, self-resetting
Supervision/Monitoring
AC ON LED indicator: 6mA
DC ON LED indicator: 6mA
Trouble notification: SPDT Form C 200mA
120VAC
UL 294
RoHS lead free
Operating Temperature: -4 to +104˚F
[-20 to +40˚C]
Humidity: 95% RH non condensing
Dimensions
Enclosure: 14”x 14” x 4.75”
Power Board: 7.4” x 3.94” x 2.35”
Mounting: 3.5” x 6.8”
Access Control Module: 4.82” x 3.84” x 1.4”
Mounting: 3.41” x 4.50”
Shipping Weight: 12.5lbs