• Clean, steady, accurate power output for best performance of access control equipment
• Compact modules for smaller footprint
• Universal transformer compatible with most international power
• Works in AC brownout down to 60 VAC
• Faster battery recharging under full load
• Automatic low-battery disconnect prevents deep discharge, maintains battery life
• Self-resetting circuit breakers for common conditions including:
o Overcurrent
o Thermal runaway
o Reverse battery hookup
• Fuse protected against surge for AC input and DC output
• Class 2 power limited output
• Eight (8) channel power distribution with access control and fire transfer relays
o Channels individually configurable to enable/disable with fire trigger
o Heavy duty relay per output with status LED, or group outputs by jumper
o Individual input for each output
o Power-limited, PTC-prote cted outputs, each with a green status LED indicator
o Main power LED indicates input power status
o Trigger LED indicates Fire Relay status
o Pluggable terminal b locks by channel and func t io n
• SPDT Form C output for remote monitoring of:
o AC failure
o Low battery
• Made in USA
• MagnaCare Lifetime Replacement No Fault Warranty
• UL Listed
Power Supply
The AQU243-8C8R power supply with battery
charger/backup and supervision is a single voltage
power supply that uses any AC power source from
90-240VAC/47-63Hz to provide up to 3 Amps @ 12VDC
continuous output.

SPECIFICATIONS: AQU243-8C8R
Input Voltage Operating Range
90-240VAC
47-63Hz
Maximum Output Voltage
79.2 VA
3.3 Amps @ 12VDC
Continuous Output Voltage
72 VA
3 Amps @ 12VDC
Voltage Range
9.8 – 13.67VDC/ 13.65 typical
Operating Fr e quency
27KHz
Onboard Power Output
One (1) Output
Fuse Protection
Battery: PTC 3 Amp
Current Overload: PTC, self-resetting
Thermal Runaway: PTC, self-resetting
Max board power use: 208mA
Maximum Ou t p ut Per Channe l
8 channels @ 1.04A
Fuses
Output: PTC 1.04A/channel
Holds current at 130˚F
Relays
Input Relays: 20ma required for activation
Output Relays: contacts rated 7A 125VAC max
Triggers
EOL: +/-60% of 2.2K ohms
Supervision/Monitoring
AC ON LED indicator: 6mA
DC ON LED indicator: 6mA
AC Fail notification: SPDT Form C 2 Amp
Low Battery: SPDT Form C 3 Amp
RoHS lead free
Operating Temperature: -4 to +104˚F
[-20 to +40˚C]
Humidity: 95% RH non condensing
Dimensions
Enclosure: 14”x 9” x 3.5”
Power Board: 6.4” x 3.95” x 2.35”
Mounting: 5.36” x 3.54”
Access Control Module: 4.82” x 3.84” x 1.4”
Mounting: 3.41” x 4.50”
Shipping Weight: 7.65 lbs