Secure Wireless PIRREC3 Users Manual

T«IIKm .1866) ~1fOI
~
,~~
PIR.REC3 : Seawe Wreless PetlllUlMlne PIR
Compatible wilil REC3 Re<eivers
USER MANUAL
INTRODUCTION
The PIR-REC3 was designed 10 ~erole wiri1lhe REC3 re<eiver and hOI 0 unique !JOrTn Power Saver lAPS) me<oonism whidJ eriOOJes tronsminer ocIivolion amy 2 mioo!es oher the lost movement hOI been deleded.
FEATURES
.60 lhs Pel Immune .High ~ile Ught Immunity .50 x 50 Covefoge .Quod 8ement PIR .WoIl Of Ce~ing Moontlnduded .long Ronge Curtain 10ptW) .Ultra High While lighllmmunity lens IOpliord)
.Slate-of-lhHrt wireless PIR
.low current ASIC PIR Te<hnology .Powered by 0 3Vo!IlithftJm bonery .Bonery life: up to 4 years .Bull in Aulomoti( Power Saver lAPS)
.low Baftery (ondition signm tronlln~sion .Tesl mode for PIR [overage and RF signal
I.Calibration Free Installation
Venioo_1
OPERATION
The Wireless PIR tronsmitl the following event dolo: SUPERVISION.o periodicol tronsm~on.
Every 60 minutel indicotes detector's presence. AlARM. olorm tronsmission triggered by PIR intrusion detectKln LOW BAT. Whenever the buttery reachel 0 pre-set k>w level (2.4V) Bottery
Low signol will be sent with the next message (Supervision, Alorm, ett)
TAMPER -Whenever the PlR-RE(3 cover is removed or the unit's cover is put
buck 0 melsage will be tronsmiffed with 10mper' signal.
APS -The un~ue APS (Auto~fic Power Saver) function built in the detector
enoblel 0 battery life spun up to four years- The detector will tronsmit on~ when the kist event hos O(curred ~re thon 2 minufel prior 10 the current one-
SELECT MOUNTING LOCATION
Select the ~unfing klcafion so thot on intruder will (Joss Ihe beams of the selected pottern. As the detector is 0 wireless tronsmiffer, ond in order to toke full odvontoge from PIR ~hisfiroted operotKln, do not instoll the detector in oreos where klrge metol objects could interfere with the tronsmission of signals- It is olso odvisable to ovoid the following klrotions .Facing direct sunlight. .Facing oreas thot ~y chof!ge temperoture ropidlv. .Areos where there ore oir ducts or substontiol oirflows. .Instollofion on metol woll­The PIR-RE(3 performs better when provided wifh 0 constont ond stobie environment.
PAGE 1
MOUNTING THE DETEGOR
~ Secure Wireless Pet Immune PIR can be mounted in a corner nke standard
PIR's or by insfolling the included oordware can be eosi~ mourned to a WlJII
or ceiling
Standard Corner Mounti~
1 ) Remove the screw at the bonom of the case and open the PIR.
2) (oreful~ mourn using the screw guides for flat surface mourning or corner mourning. It is oc(eptob~ to bend the ornenno ~ightfy in order to mourn the case to the WlJII or desired surface
Wall or Ceiung Mount
We have supplied hardware 10 onoch the PIR as a WlJII or ceiling mourn. See below diagram ~ desired mourning is needed.
it[If'
2
3
PAGE 2
MOUNTING THE DETECTOR continued
"
NOTE: We do not mount the bock brocket in cose a corner mount ~ desired. If we did mount the bock bracket in production and a corner mount VIlIS desired the bock bracket wou~ need to be removed and 2 holes would then exist. There shou~ never be a ho~ where insects con enter as they can couse false
alarms
PAGE 3
SETTING UP THE DETECTOR
The sensitivity ad[ustmenf switch sels up !he detectar for narrool ar harsh enviranment canditian.
Setting !he Sensnivity Adjustment (Puke WKI!h) Jumper .Pasitian 1= Normal
.PosnKJn AUTO = Harsh The 'I' position setting is for normal aperation. The 'AUTO' posnion setting is for harsh environmentlacations wnil air draMs or small anirools.
Se"ing the Pet Immunity Level
Slide tlie swnch fa 25Kgs for larger pets up 10 60lbs or 15kgs lor smaller pets under 30lbs
ENROLLING THE PIR-REC3
The enrolling process of Ihe PIR.REC3 ~ lhe some os odding ony olher PIR. Although lhe REC3 will eventuol~ work with every manufocturer leIs ossume you desire 10 make Ihe PIR.REC3 work with an Ademco pane!. The pro<ess is similor as enrolling 0 5890PI.
I ) Enter Ademco Progromming
2) Go to the Zone you desire 31 When the keypad asks you to 'learn Serial Number' Prell and HOLD Ihe
program buffon located on the PIR board for 2 seconds. The PIR will then send 0 ser~s of 'tesllransmillions.
4) Verify the loop is set 10 '2'.
If you teach the serm! number by pressing the tamper switch, Ioo~ 4 will be
displayed. You musf then manual~ change the loop number 10 2lrom
Ihe keypad.
PAGE 4
lENS PATTERN
PAGE 5
MlliRr
A 3 V I~hium battery powe~ the unil. Thanks 10 the exdusive APS (Automatic Power Saver) characterisliCl, the ba"ery provides oooul4 years of continuous \iPeration (depending on the amount of alarms). If the ba"ery reaches a
factory presellaw level, the lOW BATTERY signal will be senl and the detector w~1 remain operational for 30 days giving enough lime 10 replace Ihe 3V lilhKJm ba"ery
BATTERY REPLACEMENT
0 Remove screw at the bo"om of Ihe case to open. 0 Take oul the old battery 0 Using a flat head screwdriver shar1the Iwa pins located behind the positive
side of the ba"ery holder forI 0 seconds This monetary shart will dischorge
011 remaining power from the cirruifl allowing a 'fresh' power up olnsloll 0 new battery according 10 polarity. CAUTION ill RISK OF EXPLOSION IF BATTERY IS REPLACEO BY AN INCORREa TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUalONS.
PAGE 6
TECHNICAL SPECIFICATIONS
Changes or modifications not expressly approved by the party responsible for  compliance could void the user's authority to operate the equipment.
Data Prato<oI Serure Wireless
Modulation Type ASK
Event Transrn~ian Alann, Tamper, Test, Supervision,
Supervision TH11ing 60 minutes
Oete<tian Method Quod Bement Oete<tian Speed 0.3 -1.S mise! Lens Type Spherical Hard Lens Oete<tian Coverage 90.S (SO x SO)
Environment Condition Jumper for Nann~ or Harsh selection Battery liIhium. 3V Type: CR 123A Current Consumption
Power Saving APS (Automatil Power Saver) Instoll Test Modes LED Indirofor (RF & Opfic) Walk Test and
Operating temperature .1 O{C to +SO{C Range
Dimensions 61 mmX 12OmmXSOmm
Federal COnIIMIkat- Commission !FCC Slatement Jhi,dewe (omp~es.;~ port lSol~e FCC Ru~. Operatian is ",bjed 10 !he lollo.;ng ~ condition, (1) l1Iis devile IntIy nat rouse harmful interfere",e, and (2) ~i, de." must accept any interferelKe roceiwd, including inlerlere",e thot moy cause undesired aperation.
Law Bot
Standby -10 mA Transmission -16 mA
Alann Transmission Tesf
(2.43'w X 4.2S'h X 2'd)