Keyless Access System Solutions
Secure Tech

Indication Leds
Red: Power
Yellow: Programming
mode
Green: successful
operation
USB Interface
Connector
Laptop/Notebook
Secure Tech www.setech.ca
ST2 Keyless Access System - Parts Description
Door Controller - Front View Door Controller - Back View
Door Controller - Wall Supporting Plate Proximity Reader
Proximity Keyfob Locking Device Protection Diode
USB Interface Cable Power Supply
Phone: 1-416-477-9993 www.setech.ca Fax: 1-866-655-6342

Access Control One (1) Door
Access Control Two (2) Doors
AC Power outlet
110VAC/220VAC
Magnetic lock
Choose Electric
Strike or
Magnetic lock
Magnetic lock
Door contact (Optional)
Choose Electric
Strike or
Magnetic lock
Door controller module
(installed indoors)
Door controller module
(installed indoors)
Magnetic lock
Door contact (Optional)
Choose Electric
Strike or
Magnetic lock
Release push button
Door2 (optional)
Release push button
Door1 (optional)
Release push
button (optional)
Laptop to perform
management operations
Laptop to perform
management operations
Choose locking device: electric strike or magnetic lock
Choose locking device: electric strike or magnetic lock
Choose locking device: electric strike or magnetic lock
Secure Tech www.setech.ca
Installation diagrams
Phone: 1-416-477-9993 www.setech.ca Fax: 1-866-655-6342

Access Control one (1) Door + Exit Registration
AC Power outlet
110VAC/220VAC
Magnetic lock
Door contact (Optional)
Choose Electric
Strike or
Magnetic lock
Release push
button (optional)
Laptop to perform
management operations
Proximity Card
Reader - Exit
Registration
Choose locking device: electric
strike or magnetic lock
Secure Tech www.setech.ca
Phone: 1-416-477-9993 www.setech.ca Fax: 1-866-655-6342

Secure Tech www.setech.ca
Controller Module: Board connectors description and recommended cables
Recommended Cables:
Proximity Reader:
6 Conductors x 22 AWG - Shielded
(5 cables used). Maximum distance: 300 feet (100 meters)
Electric Strike or Magnetic Lock:
Option 1: 2 Conductors x 18 AWG
Option 2: Quad cable: 4 conductors x 22 AWG
Power supply:
Option 1: 2 Conductors x 18 AWG
Option 2: Quad cable: 4 Conductors x 22 AWG
Door Contact:
2 Conductors x 22 AWG
Door Release (REX):
2 Conductors x 22 AWG
Phone: 1-416-477-9993 www.setech.ca Fax: 1-866-655-6342

Door contact (normally
open)
Proximity Reader
Cables
Red - +Vcc
Black - Gnd
Green – Data0
White – Data1
Blue - Led
Grey – No connection
Yellow – No connection
Brown – No connection
V V V V V V
2 2 2 1 1 1
C N N C N N
0 C 0 C
Secure Tech www.setech.ca
Typical connection with 12VDC Electric Strikes
Phone: 1-416-477-9993 www.setech.ca Fax: 1-866-655-6342

Secure Tech www.setech.ca
Phone: 1-416-477-9993 www.setech.ca Fax: 1-866-655-6342

Secure Tech www.setech.ca
Installation Instructions:
1) Make the necessary holes in the wall for: Door controller, proximity reader, prepare the door frame to
install the locking device
2) Run cables for proximity reader, electric lock, DC power supply and door contact(optional
3) Install the proximity reader, Electric Lock or Magnet Lock
4) Unscrew the four screws on the back of the door controller
5) Connect and screw the cables(electric lock, proximity reader, DC power, door contact, door release) to
the controller connectors
6) Push the controller aligning the clicking supports females(door controller) and the clicking supports
males (wall supporting plate)
7) Plug the power supply to the AC power outlet(110AC or 220 AC)
Software Download:
Download ST2 Management software.
Specific software versions for:
Companies and institutions
Commercial buildings
Residential buildings
Households