The Horstmann Electronic 7 is an advanced water heating control, which can be programmed to
take advantage of cheap night-rate electricity, so that there is a tank of hot water available for the
morning.
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON
AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WARNING : ISOLATE MAINS SUPPLY. BEFORE COMMENCING INSTALLATION ENSURE THE UNIT IS PROPERLY EARTHED
.
The Electronic 7 is supplied with its own surface mounting box, which can also be mounted over a
single or double gang flush wall box. It should NOT be mounted on an unearthed metal surface.
Means of disconnection from the supply having at least 3mm contact separation in both poles must
be incorporated in the fixed wiring.
Horstmann recommends a separate fused circuit from the consumer unit (24 Hour supply) protected
by a 15 amp HRC fuse or, preferably, a 16 amp MCB. In some cases immersion heater failure can
damage the ELECTRONIC 7. Installation of a 100 mA RCD will provide additional protection for the
unit. If the ELECTRONIC 7 is to be connected to a ring main then the spur feeding the controller
should be protected in the same way.
4) Default Time Settings
DEFAULT TIMES
1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF
2:15am 7:15am 12:00am 12:00am 12:00am 12:00am
After re-setting the unit the off-peak heating times will revert back to the default factory settings,
these are shown above, however if you wish to change these times please proceed as instructed in
the SETTING OFF-PEAK HEATINGS PERIODS part of this manual (3).
5) Completing The Installation
To assemble the controller to its mounting box, first push the connectors numbered 1-5 into the
corresponding numbered terminal as shown in Fig.1
Carefully offer the controller to the box and secure with the fixing screws, ensuring the wiring does
not become damaged.
Switch on the mains supply and put the rocker switch in the TIMED position.
6) Questions
(Q) There is no display on the screen?
(A) Ensure there is mains supply getting to the unit and that the battery switch on the rear of the
unit is in either the GMT/BST or GMT ONLY position.
(Q) The display has become frozen?
(A) This could be due to local electrical interference. Using the RESET procedure in this manual may
rectify the fault.
(Q) How do I change the back-up battery?
(A) The back-up battery is integral to the unit and will save the settings for at least two years if the
power is disconnected. The battery is NOT replaceable and any attempt to remove it will invalidate
the warranty.
Specification
13A 230V AC 50Hz
Suitable for immersion heaters up to 3kw
Type 1 control; Type 1B disconnection
Live Parts - Enclosed
Pollution degree 2
Shock protection - Class 1
Contacts - Micro disconnection
Class A software
Impulse rating = 4000v
Battery Reserve - approximately 2 years total power disconnection
Size - 170mm x 115mm x 60mm (excluding rocker switch)
Electronic 7 Installation Instructions
1) Resetting The Unit
Sometimes electronic equipment can become scrambled or frozen. To overcome this you should
reset the unit.
This can be achieved by holding down the buttons marked “BOOST, MINUS, PLUS & SELECT”
si-multaneously.
The clock should now be adjusted to the correct time of day by following section 2 below
2) Setting Time Of Day
3) Setting Off-Peak Heating Periods
Press the
green “SET”
button until the
indicator on the
left hand side
of the screen is
next to “CLOCK”.
Adjust the hour
by pressing
the white
“MINUS” or
“PLUS” buttons.
Once you are
happy with the
hour selected,
press the blue
“SELECT” button.
The minutes
will now flash.
To adjust the
minutes you
need to once
again press the
“MINUS” or
“PLUS” buttons.
Once you are
happy with the
time selected,
press the blue
“SELECT” button,
this will now
take it back
to the “RUN”
position on the
left hand side of
the screen.
Press the green SET
button until the
indicator on the left
hand side of the screen
is next to “OFF PEAK
PROGRAMME”
The hour will now
flash for the 1st on
time, this can be
adjusted by pressing
the “MINUS” and
“PLUS” buttons. Once
you are happy with the
hour you have selected
press the “SELECT”
button
This will then make
the minutes flash,
which can be adjusted
by pressing the
“MINUS” and “PLUS”
buttons as required.
Once you are happy
with the minutes,
press the “SELECT”
button to take you to
the 1st off time
Use the “MINUS” and “PLUS” buttons to adjust the hour.
When you are happy with the hour selected then press
the “SELECT” button which shall now take you to the
minutes. Press the “MINUS” and “PLUS” buttons to SELECT
the minutes you require and once you are happy with the
minutes press the “SELECT” button.
The hour will be
flashing on the 2nd
on time, if this is not
required then press
the green “SET” button
which will take you
back to the main
screen.
If your electricity tariff offers multiple off peak periods then the 2nd and 3rd off peak periods should
be set up by repeating the above procedure. Should you not require any further off-peak settings
ensure that the remaining periods are set at the same time. For example; 2nd on 12:00pm – 2nd
Off 12:00pm; 3rd On 12:00pm – 3rd Off 12:00pm (These are de-fault settings).
Horstmann Controls Limited
South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP
Tel: 0117 9788 773 Fax: 0117 9788 701
E-mail: sales@horstmann.co.uk
Web site: www.horstmann.co.uk
Leaflet number NP0083080000 – Issue 2