INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WWAARRNNIINNGG :: IISSOOLLAATTEE MMAAIINNSS SSUUPPPPLLYY BBEEFFOORREE CCOOMMMMEENNCCIINNGG IINNSSTTAALLLLAATTIIOONN
FFIITTTTIINNGG TTHHEE BBAACCKKPPLLAATTEE
DDIIRREECCTT WWAALLLL MMOOUUNNTTIINNGG
Offer the plate to the wall in the position where the programmer is to be mounted, remembering that the Backplate fits to the right hand end of the programmer. Mark the fixing positions through the slots in the Backplate (Fixing centres 60.3mm), drill and plug the wall, then secure the plate in position. The slots in the Backplate will compensate for any misalignment of the fixings.
WWIIRRIINNGG BBOOXX MMOOUUNNTTIINNGG
The Backplate may be fitted directly on to a single gang steel flush wiring box complying with BS4662, using two M3.5 screws. ChannelPlus series 2 programmers are suitable for mounting on a flat surface only, they must not be positioned on a surface mounted wall box or on unearthed metal surfaces.
EELLEECCTTRRIICCAALL CCOONNNNEECCTTIIOONNSS
All necessary electrical connections should now be made. Flush wiring can enter from the rear through the aperture in the Backplate. Surface wiring can only enter from beneath the programmer and must be securely clamped. The mains supply terminals are intended to be connected to the supply by means of fixed wiring. The recommended cable sizes are 1.0mm
2
or 1.5mm2.
Page 1Page 4
LEAFLET No P82694
ISSUE 1
SSPPEECCIIFFIICCAATTIIOONN HH2211XXLL -- HH2277XXLL -- HH2277ZZXXLL SSEERRIIEESS22
CCoonnttaacctt ttyyppee::
Micro dis-connection(Voltage free)
CCoonnttaacctt rraattiinngg::
3(1)Amps 230-240V AC
PPoowweerr ssuuppppllyy::
230V AC 50Hz
OOppeerraattiinngg TTeemmppeerraattuurree rraannggee::
0oC to 40oC DDoouubbllee iinnssuullaatteedd.. DDiirrtt pprrootteeccttiioonn::
Normal situations.
EEnncclloossuurree pprrootteeccttiioonn::
IP30
PPuurrppoossee ooff ccoonnttrrooll::
Electronic time switch IInnddeeppeennddeennttllyy mmoouunntteedd ccoonnttrrooll ffoorr ssuurrffaaccee mmoouunnttiinngg.. OOppeerraattiinngg ttiimmee lliimmiittaattiioonn::
Continuous
BBaatttteerryy TTyyppee::
Lithium
CCaassee mmaatteerriiaall::
Thermoplastic, flame retardant
DDiimmeennssiioonnss::
163mm x 101mm x 37mm
DDiissppllaayy::
Fully graphical LCD, back-lit
CClloocckk::
24hour /12 hour AM/PM
DDiissppllaayy ttiimmee aaddjjuussttmmeenntt::
1 Minute steps
SSwwiittcchheedd ttiimmee aaddjjuussttmmeenntt::
10 Minute steps
PPrrooggrraammmmee sseelleeccttiioonn::
Auto, On all day, On constant, Off, Holiday
OOppeerraattiinngg ppeerriiooddss ppeerr ddaayy::
Three per channel - (Separate daily programmes for H27ZXL and H27ZXL) OOvveerrrriiddee::
Boost, 1 or 2 Hours Extension to ON period, 1Hr or 2Hr Instant Advance
BBaacckkppllaattee::
9 Pin terminal connection
Horstmann Controls Limited
Bristol
BS4 1UP
t:0117 9788 773 - f:0117 9788 701
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
Lower the front flap of the unit. On right hand Channel press the ADVANCE(Enter) and SELECT(Blue) buttons together then release the buttons and the programmer will return to the preset factory settings.
RREESSEETT PPRROOCCEEDDUURREE
Electronic equipment can in some circumstances be affected by electrical interference. If the display becomes frozen or scrambled; or if you wish to revert back to the default settings please use the following procedure.
RREESSEETTTTIINNGG TTHHEE CCHHAANNNNEELLPPLLUUSS XXLL SSEERRIIEESS 22
GGEENNEERRAALL IINNFFOORRMMAATTIIOONN
BBAATTTTEERRYY
The programmer is fitted with a non-rechargeable, non-serviceable long life battery, which will maintain the programmed time settings with the mains supply disconnected. THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank.
HHoorrssttmmaannnn CChhaannnneellPPlluuss XXLL SSeerriieess 22 -- TTwwoo CChhaannnneell PPrrooggrraammmmeerr..
Each channel offers up to three programmed operating periods per day, with independent Boost and Advance control on Fully Pumped Systems. This model has a fully graphical, back-lit display combined with simple menu driven programming. It is also a suitable direct replacement for existing Horstmann ChannelPlus H21XL, H27XL and H27ZXL programmers, utilising existing wiring and backplate connections.
Before handing over the installation to the user, always ensure that the system responds correctly on all control programmes and that other electrically operated equipment and controls are correctly adjusted.
EEXXPPLLAAIINN HHOOWW TTOO OOPPEERRAATTEE TTHHEE CCOONNTTRROOLLSS AANNDD HHAANNDD OOVVEERR TTHHEE UUSSEERRSS OOPPEERRAATTIINNGG IINNSSTTRRUUCCTTIIOONNSS TTOO TTHHEE UUSSEERR..
PPLLEEAASSEE NNOOTTEE;;
Using this procedure will restore the ChannelPlus to the original factory
programme settings, the time setting will also default to
11sstt JJaannuuaarryy 22000055
- See Adjusting
Time and Date on page 3 of the user guide.
ADVANCE
SELECT
BOOST
RESET
Page 2
CCOOMMMMIISSSSIIOONNIINNGG TTHHEE PPRROOGGRRAAMMMMEERR
Ensure all dust and debris has been cleared away from the work area before removing the programmer from its packaging. All ChannelPlus XL controls are fitted with battery reserve which maintains programmed times in the event of a mains power failure.
RREEAARR VVIIEEWW OOFF CCHHAANNNNEELLPPLLUUSS XXLL PPRROOGGRRAAMMMMEERR
FFIITTTTIINNGG TTHHEE PPRROOGGRRAAMMMMEERR
If surface wiring has been used, remove the knockout/insert from the bottom of the programmer to accommodate it. Loosen the two ‘captive’ retaining screws on the top of the unit. Now fit the programmer to the Backplate, line the lugs on the programmer with the flanges on the Backplate. Swing the top of the programmer into position ensuring that the connection blades on the back of the unit locate into the terminal slots in the backplate. Tighten the two ‘captive’ retaining screws to fix the unit securely, then switch on the mains supply.
END VIEW OF CHANNELPLUS PROGRAMMER
1 - RETAINING SCREWS
2 - CONNECTOR BLADES
3 - PRODUCTION DATE LABEL
4 - POSITIONING LUGS
5 - RATINGS LABEL
6 - FULLY PUMPED / GRAVITY LINK
(REMOVABLE, SEE NOTE BELOW)
1
2
3
4
5
IINNIITTIIAALL SSEETT--UUPP
Once the mains power has been switched on the ChannelPlus XL Series 2’s display will illuminate. The programmer has a number of pre-programmed functions to assist the installation, which are detailed below; TTIIMMEE AANNDD DDAATTEE --
The programmer has been pre-set with the current time and date during manufacture. No alteration should be required to the time and date, however if any modification is required please refer to the ‘Adjusting Time and Date’ section of the user guide.
PPRROOGGRRAAMMMMEE TTIIMMEESS --
The programmer has been pre-set with default heating and hot water times, these can be altered to meet the user requirements, please refer to the ‘Setting the Programme Times’ section of the user guide.
PPLLEEAASSEE EENNSSUURREE TTHHAATT TTHHEE UUSSEERR GGUUIIDDEE IISS HHAANNDDEEDD OOVVEERR TTOO TTHHEE EENNDD UUSSEERR..
Page 3
ChannelPlus programmers are double insulated and do not require an Earth connection but an Earth terminal is provided on the Backplate for terminating any Earth connections. Earth continuity must be maintained and all bare Earth conductors must be sleeved. Ensure that no conductors are left protruding outside the central space enclosed by the Backplate.
EELLEECCTTRRIICCAALL CCOONNNNEECCTTIIOONNSS
Gravity Hot water with Pumped Heating via RoomStat and CylinderStat
Gravity Hot water with Pumped Heating via RoomStat and CylinderStat including Frost protection via double pole FrostStat
Gravity Hot water with Pumped Heating via RoomStat, CylinderStat and Two Port Zone Valve (with Changeover Auxiliary Switch) on Hot Water circuit
Fully Pumped Heating System using RoomStat, CylinderStat and Three Port Mid-Position Valve
Fully Pumped System using RoomStat and CylinderStat and Two (2 Port) Motorised Valve with Auxiliary Switches
Fully Pumped System using RoomStat and Two (2 Port) Spring Return Zone Valve with Auxiliary Switches
NNOOTTEE::
When fitted in conjunction with suitably rated contactors the H27ZXL can also be used to control two Zones of
Electric heating
When used to control MAINS VOLTAGE SYSTEMS Terminals L,2 and 5 should be electrically linked by means of a suitable piece of sleeved conductor. When used to control EXTRA LOW VOLTAGE SYSTEMS these links MUST NOT be fitted. Example circuit diagrams are shown below. These diagrams are schematic and should be used as a guide only.
PPlleeaassee eennssuurree tthhaatt aallll iinnssttaallllaattiioonnss ccoommppllyy
wwiitthh tthhee ccuurrrreenntt IIEEEE rreegguullaattiioonnss..
INTERNAL WIRING DIAGRAM H21XL - H27XL
For reasons of space and clarity the diagrams have been simplified, for instance some Earth connections have been omitted. Other control components shown in the diagrams i.e. Valves, RoomStats etc. are general representations only. However the wiring detail can be applied to the corresponding models of most manufacturers e.g. Horstmann, Honeywell, Danfoss Randall etc.
CCyylliinnddeerr aanndd RRoooomm TThheerrmmoossttaatt KKeeyy:: CC == CCoommmmoonn CCAALLLL == CCaallll ffoorr hheeaatt oorr bbrreeaakk oonn rriissee SSAATT == SSaattiissffiieedd oonn rriissee NN == NNeeuuttrraall
6
FFUULLLLYY PPUUMMPPEEDD // GGRRAAVVIITTYY LLIINNKK
All ChannelPlus programmers are suitable for either gravity or fully pumped systems. On fully pumped systems it is possible to programme independent time settings for each channel, gravity systems allow only one common time setting. As supplied the ChannelPlus is suitable for fully pumped systems and the link should remain in situ, If the programmer is to control a gravity system this link should be removed by simply pulling it out of the back of the programmer.