Securefast SBL365.SL.94, SBL365.SL.94R Installation Instructions Manual

T/040/SBL365.94
17th October 2013
SBL365.SL.94/94R
Installation Instructions for SBL365.SL.94/94R Digital Mechanical Lock with Mortice Night Latch
This lock has been Fire Tested in accordance with BS EN1634-1 with the use of Intumescent Seals.
IMPORTANT: This lock must only be used with a Securefast approved lock or latch. Any lock or latch used in conjunction with this unit that has not been tested and approved by Securefast PLC will void any guarantee.
Setting the Code
On the reverse of the Digital Lock Unit you will see slotted buttons which
correspond to the push buttons on the front of the lock.
To set a button to operate within the code turn the slotted button relating to
the number so that the dot is facing outwards (towards the ‘G’)
To take a button out the code turn the slotted button so the dot is facing
inward (towards the ‘F’)
Check the code on the Lock functions before fitting the lock.
Installation
Applying the Intumescent Seals
IMPORTANT: In order for this unit to maintain its fire rating status and be suitable to be installed on a fire rated door Intumescent Seals must be used. A 2mm self-adhesive mono-ammonium phosphate (Interdens) intumescent seal is recommended.
Cover the edges and faces of the mortice lock case in one uniform layer using the self-adhesive
intumescent seal
Affix one 2mm intumescent layer behind forend of lock and behind the rear of the striker prior to
installation.
BEFORE INSTALLATION PLEASE:
1) Ensure all parts work properly
2) Choose and set a code
following the “Setting/Changing the Code” instructions. All or part
of the push-buttons can be chosen in no particular order. Codes with 4 digits provide maximum security
3) Ensure that both lever handles of the Digital Lock can be moved freely. Check that the Passage function can be engaged. Check the latch of the lock moves freely by pressing it in and by turning the follower with the spindle. Also check the functions of the Night Latch with the cylinder.
LIST OF PARTS
1) Striker
2) Mortice Night Latch
3) Security Escutcheon
4) Bolt through fixings for Escutcheon (x 2)
5) Single Cylinder
6) Neoprene Seal (x 2)
7) Internal Block
8) Digital Lock with Lever Handle
9) Spindle (8mm)
10) Cylinder Retaining Screw
11)Wood screws x 4 (For securing Lock and Striker Plate)
T/040/SBL365.94
17th October 2013
SBL365.SL.94/94R
Applying the Template
Correctly position and tape the template, T/036/SBL365.SL , to the internal door
face, at the desired height from the floor level. Ensure that the relevant, marked, door edge on template is correctly aligned with actual door edge. (Figure 1)
Mark the 19mm diameter hole for the spindle of the Digital Lock, the two 7mm
holes for the bolt through fixings, the 19mm and 14mm diameter holes for the cylinder and the two 9mm holes for the security escutcheon.
Drill all marked holes. Using a Wood Chisel clear the excess material between the two holes drilled, for the
cylinder, to create one clear opening.
Prepare and Install the Mortice Night Latch, as per separate instructions, ensuring the follower
has been correctly aligned with the spindle of the Digital Lock.
Fixing the Spindle
Identify the spindle, collar and pin and assemble as shown in Figure 2.
Feed the radius end of the spindle through the spindle collar and then insert the pin through the hole in the spindle so it is secure within the collar.
Remove small back plate from the reverse side of Digital Lock, which is held in place by 3
fixing screws.
Locate spindle assembly collar into reverse of Digital Lock and re-secure small back plate
with the 3 fixing screws.
Positioning of Spindle for Digital Lock
For Left handed applications the spindle should be fully rotated anti-
clockwise prior to locating it in the follower of the Lock Case.
For Right handed applications the spindle should be fully rotated clockwise
prior to locating it in the follower of the Lock Case.
Fixing the Lock
Cut the fixing bolts to suit door thickness, for the Digital Mechanical Lock, allowing at least 4/5
threads to screw into the lock case.
Locate the rubber seal behind the Digital Lock and position unit on the external door face locating
the spindle into the follower of the lock. Position the internal block with rubber seal on the spindle using the fixing bolts to secure the top and bottom of the Lock to the door.
Before final tightening ensure the lock is vertical and test mechanism to ensure that it is moving
freely.
Installing Cylinder and Security Escutcheon
Correctly position cylinder in Lock Case and secure using the cylinder retaining screw supplied. Position the Security escutcheon in the two 9mm holes and secure to the door using the bolt
through fixings ensuring the heads of the fixings are on the internal door face.
Using the Key check the functions of the Night Latch work as intended.
Figure 1
Spindle
Spindle
Door edge
Figure 1
Figure 2
T/040/SBL365.94
17th October 2013
SBL365.SL.94/94R
Passage Function
This allows Free Entry Mode; the outside lever will retract the latch bolt without the use of the Code.
To enable the feature follow the steps below:
Enter the correct code Press the handle down to 25-75 and push the “F” button Return the handle to the horizontal position and release the “F”
button
Do Not depress the ‘F’ Button before the handle is in the horizontal position otherwise the passage function will not engage correctly.
To cancel Free Entry Mode:
Press the “C” button and press the handle down to 25-75Return the handle to the horizontal position and release the “C”
button
75
25
Loading...